title: "Whirlpool Corporation WVW73UC0LS Bath Fan (132.2 CFM)"
url: https://siematic-charleston.com/ventilation-fans/whirlpool-corporation-wvw73uc0ls/
description: "ENERGY STAR specs for Whirlpool Corporation WVW73UC0LS: 132.2 CFM, 4.9 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Whirlpool Corporation WVW73UC0LS Exhaust Fan Specifications

ENERGY STAR PD #2383390 · Range Hood · Qualified 2021-08-12

Verified Specification Summary

Certified by EPA ENERGY STAR, Whirlpool Corporation WVW73UC0LS delivers 132.2 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 132 sq ft (8-ft height) or 117 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Whirlpool Corporation WVW73UC0LS Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 132.2 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.9 CFM/W (#519/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 27.0 W (9.9 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Whirlpool Corporation WVW73UC0LS vs. 1,145-Model ENERGY STAR Benchmarks show?

Whirlpool Corporation WVW73UC0LS (EPA filing PD #2383390) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 132.2 CFM (#229 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Whirlpool Corporation's 2-unit lineup, WVW73UC0LS (series: WVW73UC0LS) carries PD #2383390 dating to 2021-08-12. Lighting kit: No. At 4.9 CFM/W (#519 of 1,145, top 46.6% of 1,145 rated models, more efficient than 53.4% of rated models, 0.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 27.0 watts, about 9.9 kWh/yr (~$1.58/yr at $0.16/kWh) for 1 hr/day shower timers or 236.5 kWh/yr (~$37.84/yr) continuously. Closest competing matches include Broan QT130E (130.0 CFM) and Broan QT130LE (130.0 CFM).

## Why does rigid 6 in. diameter ducting protect Whirlpool Corporation WVW73UC0LS airflow?

Connecting Whirlpool Corporation WVW73UC0LS through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Whirlpool Corporation WVW73UC0LS performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Whirlpool Corporation WVW73UC0LS lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Whirlpool Corporation (2 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | WVW73UC0LS / WVW73UC0LS | PD ID 2383390 (Qualified 2021-08-12) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (132.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Whirlpool Corporation WVW73UC0LS?

Calculated coverage metrics translate Whirlpool Corporation WVW73UC0LS airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Whirlpool Corporation WVW73UC0LS

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 132 sq ft | 1 CFM/sq ft @ 132.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 117 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 82 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.9 kWh/yr (~$1.58/yr) | 27.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 236.5 kWh/yr (~$37.84/yr) | 27.0 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Whirlpool Corporation WVW73UC0LS?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT130E**](https://siematic-charleston.com/ventilation-fans/broan-qt130e-4429508/) | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Nutone QTN130LE1**](https://siematic-charleston.com/ventilation-fans/nutone-qtn130le1/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Greenheck SP-B110ES**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b110es/) | 118 / 100 CFM | 1.5 sones | 4.0 CFM/W | 6 in. diameter |
| [**Loren Cook Company GC-242**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-242/) | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |

## Does Whirlpool Corporation WVW73UC0LS match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Whirlpool Corporation WVW73UC0LS percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Whirlpool Corporation WVW73UC0LS?

Compare where Whirlpool Corporation WVW73UC0LS excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 82 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 132.2 CFM net static output
- **Suited to:** Collar pairs with 6 in. diameter duct straight outdoors

## Which homeowner questions come up most for Whirlpool Corporation WVW73UC0LS?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Whirlpool Corporation WVW73UC0LS.

### Can Whirlpool Corporation WVW73UC0LS serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Whirlpool Corporation WVW73UC0LS supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Whirlpool Corporation WVW73UC0LS for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Whirlpool Corporation WVW73UC0LS lacks adequate reserve.

### How does Whirlpool Corporation WVW73UC0LS handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Whirlpool Corporation WVW73UC0LS yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

### Is Whirlpool Corporation WVW73UC0LS quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Whirlpool Corporation WVW73UC0LS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Whirlpool Corporation WVW73UC0LS energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Whirlpool Corporation WVW73UC0LS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Whirlpool Corporation WVW73UC0LS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Whirlpool Corporation WVW73UC0LS?

Whirlpool Corporation WVW73UC0LS features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Whirlpool Corporation WVW73UC0LS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Whirlpool Corporation WVW73UC0LS's safe coverage footprint from 50 sq ft to 44 sq ft.

## Where can you explore more benchmarks around Whirlpool Corporation WVW73UC0LS?

Use the related reference pages and estimators below to cross-check Whirlpool Corporation WVW73UC0LS against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Air King F130D Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-f130d/)
- [Air King QFAMD Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-qfamd/)
- [Field Controls FAPV-L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/field-controls-fapv-l/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)