#  Win Air BPT14-13E Exhaust Fan Specifications

ENERGY STAR PD #2376698 · Bathroom/Utility Room · Qualified 2021-04-16

Verified Specification Summary

Homeowners specifying Win Air BPT14-13E gain 70 CFM at 0.1 in. w.g. (60.4 CFM at 0.25 in. w.g.) where it registers #24 of 607 in quietness (0.3 sones) and delivers 4.6 CFM/W efficacy, venting bathrooms up to 60 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Win Air BPT14-13E Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 70 / 60.4 CFM

- **Noise @ 0.1"**: 0.3 sones (#24/607)

- **Efficacy Rank**: 4.6 CFM/W (#578/1,145)

- **Static Retention**: 86.3% @ 0.25"

- **Motor Draw**: 15.2 W (5.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Win Air BPT14-13E vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 60.4 CFM out of 70 CFM (86.3% retention, 1.4 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2376698 verifies BPT14-13E (series: BPT) under Win Air (3 listed models, qualified 2021-04-16). Lighting kit: No. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 15.2 watts, about 5.5 kWh/yr (~$0.88/yr at $0.16/kWh) for 1 hr/day shower timers or 133.2 kWh/yr (~$21.31/yr) continuously. Closest competing matches include Tech Drive TD-BF-06 (70.0 CFM) and Dayton 3DPE2 (63.0 CFM).

## What acoustic percentile does Win Air BPT14-13E occupy among 1,145 bath blowers?

Inspect how Win Air BPT14-13E positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Win Air BPT14-13E best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Win Air BPT14-13E housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Win Air BPT14-13E acoustic and static metrics stand?

Compare Win Air BPT14-13E published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Win Air (3 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BPT14-13E / BPT | PD ID 2376698 (Qualified 2021-04-16) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (60.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.3 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Win Air BPT14-13E handle taller ceilings or walk-in tub steam?

Evaluate how Win Air BPT14-13E scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Win Air BPT14-13E

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.5 kWh/yr (~$0.88/yr) | 15.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 133.2 kWh/yr (~$21.31/yr) | 15.2 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Win Air BPT14-13E?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Tech Drive TD-BF-06**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-06/) | 70 / 60.4 CFM | 0.3 sones (Same) | 4.6 CFM/W | 4 in. diameter |
| [**Dayton 3DPE2**](https://siematic-charleston.com/ventilation-fans/dayton-3dpe2/) | 63 / N/A CFM | 0.4 sones (+0.10) | 4.0 CFM/W | 6 in. diameter |
| [**Greenheck SP-B50**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b50/) | 63 / N/A CFM | 0.4 sones (+0.10) | 4.0 CFM/W | 6 in. diameter |
| [**KORA SBF70N**](https://siematic-charleston.com/ventilation-fans/kora-sbf70n/) | 76.5 / N/A CFM | 0.4 sones (+0.10) | 3.8 CFM/W | 4 in. diameter |
| [**AERO PURE ABF80G15W**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80g15w/) | 80 / 62.9 CFM | 0.4 sones (+0.10) | 4.7 CFM/W | 4 in. diameter |

## Is Win Air BPT14-13E sized right for your shower or tub room?

Check whether Win Air BPT14-13E clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Win Air BPT14-13E?

Match Win Air BPT14-13E directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Best for:** Moisture load fits 60.4 CFM net static output
- **Optimal use:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Win Air BPT14-13E?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Win Air BPT14-13E.

### What happens to Win Air BPT14-13E CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Win Air BPT14-13E moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does Win Air BPT14-13E sit on acoustic comfort for senior homeowners?

Measuring 0.3 sones, Win Air BPT14-13E operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Win Air BPT14-13E cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Win Air BPT14-13E 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Win Air BPT14-13E pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Win Air BPT14-13E's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Win Air BPT14-13E?

Win Air BPT14-13E features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Win Air BPT14-13E's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Win Air BPT14-13E's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Win Air BPT14-13E ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Win Air BPT14-13E covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Win Air BPT14-13E run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Win Air BPT14-13E.

## How can you cross-check Win Air BPT14-13E against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Win Air BPT14-13E.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Tech Drive TD-BF-06-plus Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-06-plus/)
- [Air King LEDAK50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ledak50/)
- [Tech Drive TD-BF-06 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-06/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)