title: "Wintek 7140-50-PS Bath Fan (50 CFM, 2.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/wintek-7140-50-ps/
description: "ENERGY STAR specs for Wintek 7140-50-PS: 50 CFM, 2.0 sones (#522 of 607), 3.1 CFM/W, 3 in. diameter and 5 closest peer fans. Verified US agency."
---

#  Wintek 7140-50-PS Exhaust Fan Specifications

ENERGY STAR PD #3629677 · Bathroom/Utility Room · Qualified 2024-08-16

Verified Specification Summary

Certified by EPA ENERGY STAR, Wintek 7140-50-PS delivers 50 CFM free-air (41 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 3.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 41 sq ft (8-ft height) or 36 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Wintek 7140-50-PS Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 41 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 3.1 CFM/W (#1,100/1,145)

- **Static Retention**: 82.0% @ 0.25"

- **Motor Draw**: 16.1 W (5.9 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Wintek 7140-50-PS vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 41 CFM at 0.25 in. w.g. (82.0% retention, 5.7 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places 7140-50-PS (series: 7140-50-PS) (PD #3629677) among 9 Wintek entries qualified through 2024-08-16. Lighting kit: Yes. At 3.1 CFM/W (#1,100 of 1,145, below median tier among 1,145 rated models; more efficient than 3.6% of rated models, 1.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 16.1 watts, about 5.9 kWh/yr (~$0.94/yr at $0.16/kWh) for 1 hr/day shower timers or 141.0 kWh/yr (~$22.56/yr) continuously. Closest competing matches include Cyclone CE50 (50.0 CFM) and Broan 688ESL (50.0 CFM).

## How noisy is Wintek 7140-50-PS compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Wintek 7140-50-PS measures 2.0 sones across the 1,145-model registry.

## Why does rigid 3 in. diameter ducting protect Wintek 7140-50-PS airflow?

Connecting Wintek 7140-50-PS through rigid 3 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Wintek 7140-50-PS performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Wintek 7140-50-PS lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Wintek (9 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 7140-50-PS / 7140-50-PS | PD ID 3629677 (Qualified 2024-08-16) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | CONTINUOUS ONLY (41 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What room sizes and annual power draw fit Wintek 7140-50-PS?

Calculated coverage metrics translate Wintek 7140-50-PS airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Wintek 7140-50-PS

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 41 sq ft | 1 CFM/sq ft @ 41 CFM |
| Tall Bath (9-ft Ceiling) | Up to 36 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.9 kWh/yr (~$0.94/yr) | 16.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 141.0 kWh/yr (~$22.56/yr) | 16.1 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Wintek 7140-50-PS?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Cyclone CE50**](https://siematic-charleston.com/ventilation-fans/cyclone-ce50/) | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| [**Broan 688ESL**](https://siematic-charleston.com/ventilation-fans/broan-688esl/) | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| [**Broan-Nutone 688E**](https://siematic-charleston.com/ventilation-fans/broan-nutone-688e/) | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| [**Broan-Nutone 688E = 1667EH with 1688EF**](https://siematic-charleston.com/ventilation-fans/broan-nutone-688e-1667eh-with-1688ef/) | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| [**Broan-Nutone 688E = 1667H with 1688EF**](https://siematic-charleston.com/ventilation-fans/broan-nutone-688e-1667h-with-1688ef/) | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |

## Does Wintek 7140-50-PS match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Wintek 7140-50-PS percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Wintek 7140-50-PS?

Compare where Wintek 7140-50-PS excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Supplementary continuous trickle ventilation
- **Suited to:** Collar pairs with 3 in. diameter duct straight outdoors

## Which homeowner questions come up most for Wintek 7140-50-PS?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Wintek 7140-50-PS.

### Is Wintek 7140-50-PS quiet enough for a primary bedroom bathroom?

At 2.0 sones, Wintek 7140-50-PS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Wintek 7140-50-PS energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Wintek 7140-50-PS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Wintek 7140-50-PS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Wintek 7140-50-PS?

Wintek 7140-50-PS features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Wintek 7140-50-PS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Wintek 7140-50-PS's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Wintek 7140-50-PS serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Wintek 7140-50-PS supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Wintek 7140-50-PS for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Wintek 7140-50-PS lacks adequate reserve.

### How does Wintek 7140-50-PS handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Wintek 7140-50-PS yields unlisted 0.25 in. w.g. backpressure figures, so smooth 3 in. diameter rigid metal ducting protects real exhaust.

## Where can you explore more benchmarks around Wintek 7140-50-PS?

Use the related reference pages and estimators below to cross-check Wintek 7140-50-PS against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Dayton 3DPE6A Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dayton-3dpe6a/)
- [Greenheck SP-A250 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-a250/)
- [Revent RVSX50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvsx50/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)