#  Wintek BPT13B-80-L4 Exhaust Fan Specifications

ENERGY STAR PD #2405574 · Bathroom/Utility Room · Qualified 2022-11-04

Verified Specification Summary

Rated for 80 CFM open-air (57.2 CFM at 0.25 in. w.g.), Wintek BPT13B-80-L4 registers #412 of 607 in quietness (1.5 sones) and delivers 3.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 57 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Wintek BPT13B-80-L4 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 57.2 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 3.5 CFM/W (#1,038/1,145)

- **Static Retention**: 71.5% @ 0.25"

- **Motor Draw**: 22.9 W (8.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Wintek BPT13B-80-L4 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 57.2 CFM at 0.25 in. w.g. (71.5% retention, 16.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2405574 verifies BPT13B-80-L4 (series: BPT13B-80-L4) under Wintek (9 listed models, qualified 2022-11-04). Lighting kit: No. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include HomeWerks Worldwide 7140-80 (80.0 CFM) and HomeWerks Worldwide 7140-80-G3 (80.0 CFM).

## How does Wintek BPT13B-80-L4 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Wintek BPT13B-80-L4 (1.5 sones).

## How do flex elbows choke Wintek BPT13B-80-L4 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Wintek BPT13B-80-L4 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Wintek BPT13B-80-L4 meet residential exhaust fan code specs?

Inspect Wintek BPT13B-80-L4 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Wintek (9 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BPT13B-80-L4 / BPT13B-80-L4 | PD ID 2405574 (Qualified 2022-11-04) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (57.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Wintek BPT13B-80-L4 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Wintek BPT13B-80-L4 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Wintek BPT13B-80-L4

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 57 sq ft | 1 CFM/sq ft @ 57.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 50 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |

## Which competing models share Wintek BPT13B-80-L4 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**HomeWerks Worldwide 7140-80**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7140-80/) | 80 / 57.2 CFM | 1.5 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7140-80-G3**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7140-80-g3/) | 80 / 58.8 CFM | 1.5 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| [**S&P PCV80**](https://siematic-charleston.com/ventilation-fans/s-p-pcv80/) | 80 / 60.8 CFM | 1.5 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| [**PROJECT SOURCE 8781-80-PS**](https://siematic-charleston.com/ventilation-fans/project-source-8781-80-ps/) | 80 / 61.2 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Commercial Electric 7130-18-CE**](https://siematic-charleston.com/ventilation-fans/commercial-electric-7130-18-ce/) | 80 / 64 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |

## How much airflow margin does Wintek BPT13B-80-L4 give your bath?

Run a quick local room-volume check for Wintek BPT13B-80-L4 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Wintek BPT13B-80-L4 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Wintek BPT13B-80-L4.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 57 sq ft with 8-ft ceilings (50 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Wintek BPT13B-80-L4?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Wintek BPT13B-80-L4.

### Which bathroom layouts should pick a larger blower than Wintek BPT13B-80-L4?

Do not force Wintek BPT13B-80-L4 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Wintek BPT13B-80-L4 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Wintek BPT13B-80-L4 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Wintek BPT13B-80-L4 disturb adjacent bedrooms during night use?

Acoustic measurement places Wintek BPT13B-80-L4 at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Wintek BPT13B-80-L4 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Wintek BPT13B-80-L4 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Wintek BPT13B-80-L4 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Wintek BPT13B-80-L4's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Wintek BPT13B-80-L4?

Wintek BPT13B-80-L4 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Wintek BPT13B-80-L4's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Wintek BPT13B-80-L4's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Wintek BPT13B-80-L4 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Wintek BPT13B-80-L4 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

## Which GradeMark tools pair best with Wintek BPT13B-80-L4?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Wintek BPT13B-80-L4.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan 744 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-744/)
- [Broan 744FL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-744fl/)
- [VENTECHLATION BPT13-14HD-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt13-14hd-1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)