title: "Wintek BPT15B-100H2 Bath Fan (100 CFM, 0.9 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/wintek-bpt15b-100h2/
description: "ENERGY STAR specs for Wintek BPT15B-100H2: 100 CFM, 0.9 sones (#239 of 607), 4.1 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Wintek BPT15B-100H2 Exhaust Fan Specifications

ENERGY STAR PD #3798585 · Bathroom/Utility Room · Qualified 2024-11-08

Verified Specification Summary

Homeowners specifying Wintek BPT15B-100H2 gain 100 CFM at 0.1 in. w.g. (84.1 CFM at 0.25 in. w.g.) where it registers #239 of 607 in quietness (0.9 sones) and delivers 4.1 CFM/W efficacy, venting bathrooms up to 84 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Wintek BPT15B-100H2 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 84.1 CFM

- **Noise @ 0.1"**: 0.9 sones (#239/607)

- **Efficacy Rank**: 4.1 CFM/W (#821/1,145)

- **Static Retention**: 84.1% @ 0.25"

- **Motor Draw**: 24.4 W (8.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Wintek BPT15B-100H2 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 84.1 CFM at 0.25 in. w.g. (84.1% retention, 3.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places BPT15B-100H2 (series: BPT15B-100H2) (PD #3798585) among 9 Wintek entries qualified through 2024-11-08. Lighting kit: No. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.4 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 213.7 kWh/yr (~$34.19/yr) continuously. Closest competing matches include Nektra 33003853 (100.0 CFM) and Nektra Pro 33003856 (100.0 CFM).

## What acoustic percentile does Wintek BPT15B-100H2 occupy among 1,145 bath blowers?

Inspect how Wintek BPT15B-100H2 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Wintek BPT15B-100H2 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Wintek BPT15B-100H2 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Wintek BPT15B-100H2 acoustic and static metrics stand?

Compare Wintek BPT15B-100H2 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Wintek (9 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BPT15B-100H2 / BPT15B-100H2 | PD ID 3798585 (Qualified 2024-11-08) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (84.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.9 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Wintek BPT15B-100H2 handle taller ceilings or walk-in tub steam?

Evaluate how Wintek BPT15B-100H2 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Wintek BPT15B-100H2

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 84 sq ft | 1 CFM/sq ft @ 84.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 74 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 34 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.9 kWh/yr (~$1.42/yr) | 24.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 213.7 kWh/yr (~$34.19/yr) | 24.4 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Wintek BPT15B-100H2?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Nektra 33003853**](https://siematic-charleston.com/ventilation-fans/nektra-33003853/) | 100 / 84.1 CFM | 0.9 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**Nektra Pro 33003856**](https://siematic-charleston.com/ventilation-fans/nektra-pro-33003856/) | 100 / 84.1 CFM | 0.9 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**VOTATEC VO-FN4W26-AC-100**](https://siematic-charleston.com/ventilation-fans/votatec-vo-fn4w26-ac-100/) | 100 / 85 CFM | 0.9 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**ARTIKA FAB-BRLU-C1**](https://siematic-charleston.com/ventilation-fans/artika-fab-brlu-c1/) | 100 / 95.3 CFM | 0.9 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**S&P PC110XP**](https://siematic-charleston.com/ventilation-fans/s-p-pc110xp/) | 100 / 83.8 CFM | 0.9 sones (Same) | 3.6 CFM/W | 4 in. diameter |

## Is Wintek BPT15B-100H2 sized right for your shower or tub room?

Check whether Wintek BPT15B-100H2 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Wintek BPT15B-100H2 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Wintek BPT15B-100H2 for your remodel.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 34 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Strong scenario:** Moisture load fits 84.1 CFM net static output
- **Best application:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Wintek BPT15B-100H2?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Wintek BPT15B-100H2.

### Does Wintek BPT15B-100H2 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Wintek BPT15B-100H2 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Wintek BPT15B-100H2 in a bathroom remodel?

Avoid specifying Wintek BPT15B-100H2 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Wintek BPT15B-100H2 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Wintek BPT15B-100H2 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Wintek BPT15B-100H2 occupy in EPA filings?

With 0.9 sones at 0.1 in. w.g., Wintek BPT15B-100H2 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

### How many kWh per year does Wintek BPT15B-100H2 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Wintek BPT15B-100H2 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Wintek BPT15B-100H2 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Wintek BPT15B-100H2's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Wintek BPT15B-100H2?

Wintek BPT15B-100H2 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Wintek BPT15B-100H2's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Wintek BPT15B-100H2's safe coverage footprint from 50 sq ft to 44 sq ft.

## How can you cross-check Wintek BPT15B-100H2 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Wintek BPT15B-100H2.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Loren Cook Company GC-128 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-128/)
- [Revent RVM80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvm80/)
- [Wintek BPT15B-100H1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/wintek-bpt15b-100h1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)