#  Wintek BPT15B-80H1 Exhaust Fan Specifications

ENERGY STAR PD #3798603 · Bathroom/Utility Room · Qualified 2024-11-08

Verified Specification Summary

In EPA dataset 8dv7-nngq, Wintek BPT15B-80H1 tests at 80 CFM free discharge (66.3 CFM at 0.25 in. w.g.) and registers #50 of 607 in quietness (0.4 sones) and delivers 3.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 66 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Wintek BPT15B-80H1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 66.3 CFM

- **Noise @ 0.1"**: 0.4 sones (#50/607)

- **Efficacy Rank**: 3.5 CFM/W (#1,038/1,145)

- **Static Retention**: 82.9% @ 0.25"

- **Motor Draw**: 22.9 W (8.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Wintek BPT15B-80H1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 66.3 CFM at 0.25 in. w.g. (82.9% retention, 4.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Wintek's 9-unit lineup, BPT15B-80H1 (series: BPT15B-80H1) carries PD #3798603 dating to 2024-11-08. Lighting kit: No. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include VOTATEC VO-FN4W25-AC-80 (80.0 CFM) and KORA SBF70N (76.5 CFM).

## Does Wintek BPT15B-80H1 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Wintek BPT15B-80H1 at 0.4 sones.

## Why avoid unvented attic termination with Wintek BPT15B-80H1?

Under ASHRAE 62.2 best practice, Wintek BPT15B-80H1 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Wintek BPT15B-80H1?

Before cutting ceiling drywall or sizing attic transitions for Wintek BPT15B-80H1, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Wintek (9 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BPT15B-80H1 / BPT15B-80H1 | PD ID 3798603 (Qualified 2024-11-08) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (66.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.4 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Wintek BPT15B-80H1?

Bathroom ventilation sizing below maps Wintek BPT15B-80H1 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Wintek BPT15B-80H1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 66 sq ft | 1 CFM/sq ft @ 66.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 58 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Wintek BPT15B-80H1 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Wintek BPT15B-80H1.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**VOTATEC VO-FN4W25-AC-80**](https://siematic-charleston.com/ventilation-fans/votatec-vo-fn4w25-ac-80/) | 80 / 66.3 CFM | 0.4 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| [**KORA SBF70N**](https://siematic-charleston.com/ventilation-fans/kora-sbf70n/) | 76.5 / N/A CFM | 0.4 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**Nektra 33003852**](https://siematic-charleston.com/ventilation-fans/nektra-33003852/) | 80 / 68.5 CFM | 0.3 sones (-0.10) | 3.6 CFM/W | 4 in. diameter |
| [**Broan RB80**](https://siematic-charleston.com/ventilation-fans/broan-rb80/) | 80 / 63.1 CFM | 0.3 sones (-0.10) | 3.0 CFM/W | 4 in. diameter |
| [**Broan RB80L1**](https://siematic-charleston.com/ventilation-fans/broan-rb80l1/) | 80 / 61.2 CFM | 0.3 sones (-0.10) | 2.9 CFM/W | 4 in. diameter |

## What percentage of room demand does Wintek BPT15B-80H1 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Wintek BPT15B-80H1 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Wintek BPT15B-80H1 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Wintek BPT15B-80H1 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 66.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around 0.4 sones up to 66 sq ft
- **Works well for:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Wintek BPT15B-80H1?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Wintek BPT15B-80H1.

### How loud is Wintek BPT15B-80H1 compared with a standard 3.0 sone builder fan?

Tested at 0.4 sones, Wintek BPT15B-80H1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Wintek BPT15B-80H1 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Wintek BPT15B-80H1 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Wintek BPT15B-80H1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Wintek BPT15B-80H1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Wintek BPT15B-80H1?

Wintek BPT15B-80H1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Wintek BPT15B-80H1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Wintek BPT15B-80H1's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Wintek BPT15B-80H1 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Wintek BPT15B-80H1 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Wintek BPT15B-80H1?

Rule out Wintek BPT15B-80H1 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Wintek BPT15B-80H1 capacity?

Because static drag at 0.25 in. w.g. lowers Wintek BPT15B-80H1 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

## What related resources expand on Wintek BPT15B-80H1?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [KORA SBF70N Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kora-sbf70n/)
- [Dayton 3DPE2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dayton-3dpe2/)
- [VOTATEC VO-FN4W25-AC-80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/votatec-vo-fn4w25-ac-80/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)