title: "Zephyr AK8400BS-ES Bath Fan (190 CFM, 2.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/zephyr-ak8400bs-es/
description: "ENERGY STAR specs for Zephyr AK8400BS-ES: 190 CFM, 2.0 sones (#522 of 607), 3.9 CFM/W, 6 in. diameter and 5 closest peer fans."
---

#  Zephyr AK8400BS-ES Exhaust Fan Specifications

ENERGY STAR PD #2454333 · Range Hood · Qualified 2023-03-10

Verified Specification Summary

Tested under HVI protocols, the Zephyr AK8400BS-ES exhaust unit achieves 190 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), registers #522 of 607 in quietness (2.0 sones) and delivers 3.9 CFM/W efficacy, covering standard baths up to 190 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Zephyr AK8400BS-ES Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 190 / N/A CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 48.7 W (17.8 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Zephyr AK8400BS-ES vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Free-discharge delivery reaches 190 CFM (#64 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Zephyr's 3-unit lineup, AK8400BS-ES (series: RANGE HOOD) carries PD #2454333 dating to 2023-03-10. Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 48.7 watts, about 17.8 kWh/yr (~$2.85/yr at $0.16/kWh) for 1 hr/day shower timers or 426.6 kWh/yr (~$68.26/yr) continuously. Closest competing matches include Broan ALT4306SS (190.0 CFM) and Aprilaire 8145 (190.0 CFM).

## Where do Zephyr AK8400BS-ES sones rank across EPA ENERGY STAR fans?

Comparing Zephyr AK8400BS-ES (2.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Zephyr AK8400BS-ES CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Zephyr AK8400BS-ES, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Zephyr AK8400BS-ES measure up on airflow and noise ratings?

Each row below breaks down Zephyr AK8400BS-ES certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Zephyr (3 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AK8400BS-ES / RANGE HOOD | PD ID 2454333 (Qualified 2023-03-10) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (190 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect Zephyr AK8400BS-ES CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Zephyr AK8400BS-ES

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 190 sq ft | 1 CFM/sq ft @ 190 CFM |
| Tall Bath (9-ft Ceiling) | Up to 168 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 140 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 17.8 kWh/yr (~$2.85/yr) | 48.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 426.6 kWh/yr (~$68.26/yr) | 48.7 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Zephyr AK8400BS-ES?

Compare Zephyr AK8400BS-ES side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan ALT4306SS**](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss-4481124/) | 190 / N/A CFM | Unpublished | 3.7 CFM/W | 3.25 x 14 in. rectangular |
| [**Aprilaire 8145**](https://siematic-charleston.com/ventilation-fans/aprilaire-8145/) | 190 / N/A CFM | Unpublished | 4.4 CFM/W | 6 in. diameter |
| [**Aprilaire 8145NC**](https://siematic-charleston.com/ventilation-fans/aprilaire-8145nc/) | 190 / N/A CFM | Unpublished | 4.4 CFM/W | 6 in. diameter |
| [**Broan L200EL**](https://siematic-charleston.com/ventilation-fans/broan-l200el/) | 200 / N/A CFM | Unpublished | 4.0 CFM/W | 8 in. diameter |
| [**Delta VDBFRS200HT**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |

## Can you size Zephyr AK8400BS-ES for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Zephyr AK8400BS-ES verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Zephyr AK8400BS-ES fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Zephyr AK8400BS-ES.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 190 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around 2.0 sones up to 190 sq ft
- **Target scenario:** Paired with rigid galvanized 6 in. diameter transition

## How do federal and code standards apply to Zephyr AK8400BS-ES?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Zephyr AK8400BS-ES.

### Does running Zephyr AK8400BS-ES continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Zephyr AK8400BS-ES draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Zephyr AK8400BS-ES pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Zephyr AK8400BS-ES's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Zephyr AK8400BS-ES?

Zephyr AK8400BS-ES features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Zephyr AK8400BS-ES's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Zephyr AK8400BS-ES's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Zephyr AK8400BS-ES code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Zephyr AK8400BS-ES clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Zephyr AK8400BS-ES?

Do not force Zephyr AK8400BS-ES into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Zephyr AK8400BS-ES retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Zephyr AK8400BS-ES produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

### Will Zephyr AK8400BS-ES disturb adjacent bedrooms during night use?

Acoustic measurement places Zephyr AK8400BS-ES at 2.0 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

## What neighboring pages and tools support Zephyr AK8400BS-ES?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Zephyr AK8400BS-ES.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan AMG03RSS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-amg03rss/)
- [Broan AMG03RWW Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-amg03rww/)
- [Panasonic FV-30VQ3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-30vq3/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)