---
title: "CAE 02 AB1086150/1.5 WaterSense Faucet (1.5 gpm) | GradeMark"
url: https://siematic-charleston.com/watersense-fixtures/faucet/faucet-cae-02-ab1086-150-1-5/
description: "EPA WaterSense faucet CAE 02 AB1086150/1.5: 1.5 gpm (31.8% under EPAct 1992), 1,825 gal/person/yr savings and 5 peers. Verified US agency benchmarks."
---

#  CAE 02 AB1086150/1.5 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · CAE (1 SKU)

Verified Specification Summary

The CAE 02 AB1086150/1.5 is an EPA WaterSense faucet certified at 1.5 gpm, 31.8% below EPAct 1992 (2.2 gpm) and #15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm. A 3-person household saves ~5,475 gallons/yr replacing a 2.75 gpm legacy fixture. Compare EPA WaterSense certified flow metrics for CAE 02 AB1086150/1.5 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

- **Certified Flow**: 1.5 gpm

- **vs. EPAct 1992**: -31.8% (2.2 gpm)

- **Annual Draw (1 Pers.)**: 2,190 gal/yr

- **Annual Saved vs. Legacy**: 1,825 gal/person

- **Brand EPA Count**: 132 faucets

- **Series / Variants**: 02 AB1086150/1.5 (1)

WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

## What does CAE 02 AB1086150/1.5 Benchmark & Water Budget show?

Flow standing: CAE 02 AB1086150/1.5 operates at 1.5 gpm (aggressive sub-1.6 gpm conservation tier), #15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm (0.30 gpm higher-flow than the 1.20 gpm median), cutting 31.8% off EPAct 1992 (2.2 gpm).

Pair this 1.5 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: CAE holds 132 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~5,475 gallons/yr—roughly $44/yr in low-tariff towns ($8/1k gal), $60/yr at national averages ($11/1k gal), or $99/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: AM Conservation Group, Inc. FA012CPB1WS (1.5 gpm) and Amazon 90457.05 (1.5 gpm).

## How does CAE 02 AB1086150/1.5 compare to EPAct 1992 and legacy gpm rates?

Tested at 1.50 gpm, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (2.2 gpm) and pre-1994 legacy units (2.75 gpm).

## What floor flatness and flange clearances pair with CAE 02 AB1086150/1.5?

Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.

Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

## Which EPA WaterSense test specs apply to CAE 02 AB1086150/1.5?

Certified EPA WaterSense records for CAE 02 AB1086150/1.5 verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Registry Share** | CAE (132 certified) | EPA WaterSense Partner |
| **Model Number / Series** | 02 AB1086150/1.5 | Certified Series (1 finish variants) |
| **Rated Consumption** | 1.5 gpm | Category median 1.2 gpm (n=22,471 rated) |
| **Shower / Faucet Pairing** | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |

## How much water and money can CAE 02 AB1086150/1.5 save each year?

Household projections below calculate CAE 02 AB1086150/1.5 annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.

Computed annual water savings for CAE 02 AB1086150/1.5 (1.5 gpm)

| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 2,190 gal | 1,022 gal | 1,825 gal (~$20) |
| 2 Occupants | 4,380 gal | 2,044 gal | 3,650 gal (~$40) |
| 3 Occupants | 6,570 gal | 3,066 gal | 5,475 gal (~$44–$99) |
| 4 Occupants | 8,760 gal | 4,088 gal | 7,300 gal (~$80) |

## Which EPA WaterSense fixtures match CAE 02 AB1086150/1.5?

Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.

Peer faucet models with matching or lower gpm ratings

| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| [**AM Conservation Group, Inc. FA012CPB1WS**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-am-conservation-group-inc-fa012cpb1ws/) | 1.5 gpm (Same flow) | WaterSense |
| [**Amazon 90457.05**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-amazon-90457-05/) | 1.5 gpm (Same flow) | WaterSense |
| [**Aqueous™, Estora™ or Homewerks Worldwide 20-B41CY-Z**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-aqueous-estora-or-homewerks-worldwide-20-b41cy-z/) | 1.5 gpm (Same flow) | WaterSense |
| [**Aqueous™, Estora™ or Homewerks Worldwide 30-B41WN-Z**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-aqueous-estora-or-homewerks-worldwide-30-b41wn-z/) | 1.5 gpm (Same flow) | WaterSense |
| [**Brookfield 192-8268**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-brookfield-192-8268/) | 1.5 gpm (Same flow) | CMI 3252C Chrome Two Handle Deluxe... |

## How much does CAE 02 AB1086150/1.5 save at your local water rate?

Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.

Household Occupants

Water + Sewer Rate ($ / 1k gal)

## Does CAE 02 AB1086150/1.5 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying CAE 02 AB1086150/1.5 for your remodel.

### Limitations & Who Should Skip

- Low static water supply pressure <30 PSI

### Best-Fit Homeowner Profiles

- **Strong scenario:** Claiming utility rebates across 200 U.S. WaterSense programs
- **Best application:** Lowering household draw to 2,190 gal/person/yr

## What key rules and numbers govern CAE 02 AB1086150/1.5?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting CAE 02 AB1086150/1.5.

### Does CAE 02 AB1086150/1.5 cut utility costs noticeably for a 3-person household?

Yes: cutting 21,900 gallons/yr relative to 4.0 gpm hardware translates to ~$241/yr in combined water/sewer savings at $11/1k gal.

### What anti-scald valve standard pairs with CAE 02 AB1086150/1.5?

Pairing CAE 02 AB1086150/1.5 (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

### How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

### Does installing CAE 02 AB1086150/1.5 require a municipal plumbing permit?

Like-for-like swaps using CAE 02 AB1086150/1.5 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

### What efficiency edge separates CAE 02 AB1086150/1.5 from legacy and EPAct models?

Certified at 1.5 gpm, CAE 02 AB1086150/1.5 achieves 31.8% savings against EPAct 1992 (2.2 gpm) and 62.5% savings against 4.0 gpm fixtures, 7,300 gallons per occupant yearly.

### What supply pressure checks protect CAE 02 AB1086150/1.5 spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.5 gpm trim.

### Does CAE 02 AB1086150/1.5 qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes CAE 02 AB1086150/1.5 eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

### Where does CAE 02 AB1086150/1.5 rank against other certified faucets?

Rated at 1.5 gpm, CAE 02 AB1086150/1.5 measures slightly above the 1.2 gpm WaterSense faucet median across thousands of EPA-listed residential fixtures.

## Which guides and calculators connect next to CAE 02 AB1086150/1.5?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for CAE 02 AB1086150/1.5.

- [Compare WaterSense 1.28 gpf vs 3.5 gpf toilets](https://siematic-charleston.com/compare/epa-watersense-128-gpf-vs-35-gpf-legacy-toilet/)
- [Browse all faucets in registry](https://siematic-charleston.com/watersense-fixtures/faucets/)
- [Browse 200 U.S. WaterSense utility rebates](https://siematic-charleston.com/rebates/)
- [California Faucets TO-V3802T-7 WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-california-faucets-to-v3802t-7-zz/)
- [CCF®, KOSPAK® W40XXXXXXX WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-ccf-kospak-w40xxxxxxx-xx/)
- [Brookfield 3258ORB WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-brookfield-3258orb/)

## Sources

1. [EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets)](https://lookforwatersense.epa.gov/products/) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
2. [EPA WaterSense Utility Rebate Finder API](https://www.epa.gov/watersense/rebate-finder) — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Check U.S. WaterSense Rebates

See all 51 states and 200 U.S. utility rebate programs.
[Open Rebate Directory](https://siematic-charleston.com/rebates/)
