---
title: "Crescent 84E G1 - - B6 WaterSense Faucet (1.2 gpm) | GradeMark"
url: https://siematic-charleston.com/watersense-fixtures/faucet/faucet-crescent-84e-g1-b6/
description: "EPA WaterSense faucet Crescent 84E G1 - - B6: 1.2 gpm (45.5% under EPAct 1992), 2,263 gal/person/yr savings and 5 peers. Verified US agency benchmarks."
---

#  Crescent 84E G1 - - B6 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Crescent (1 SKU)

Verified Specification Summary

The Crescent 84E G1 - - B6 is an EPA WaterSense faucet certified at 1.2 gpm, 45.5% below EPAct 1992 (2.2 gpm) and #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets. A 3-person household saves ~6,789 gallons/yr replacing a 2.75 gpm legacy fixture. Compare EPA WaterSense certified flow metrics for Crescent 84E G1 - - B6 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

- **Certified Flow**: 1.2 gpm

- **vs. EPAct 1992**: -45.5% (2.2 gpm)

- **Annual Draw (1 Pers.)**: 1,752 gal/yr

- **Annual Saved vs. Legacy**: 2,263 gal/person

- **Brand EPA Count**: 46 faucets

- **Series / Variants**: 84E G1 - - B6 (1)

WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

## What does Crescent 84E G1 - - B6 Benchmark & Water Budget show?

Flow standing: Crescent 84E G1 - - B6 operates at 1.2 gpm (aggressive sub-1.6 gpm conservation tier), #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets, cutting 45.5% off EPAct 1992 (2.2 gpm).

Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Crescent holds 46 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).

## How does Crescent 84E G1 - - B6 compare to EPAct 1992 and legacy gpm rates?

Tested at 1.20 gpm, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (2.2 gpm) and pre-1994 legacy units (2.75 gpm).

## What floor flatness and flange clearances pair with Crescent 84E G1 - - B6?

Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.

Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

## Which EPA WaterSense test specs apply to Crescent 84E G1 - - B6?

Certified EPA WaterSense records for Crescent 84E G1 - - B6 verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Registry Share** | Crescent (46 certified) | EPA WaterSense Partner |
| **Model Number / Series** | 84E G1 - - B6 | Certified Series (1 finish variants) |
| **Rated Consumption** | 1.2 gpm | Category median 1.2 gpm (n=22,471 rated) |
| **Shower / Faucet Pairing** | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |

## How much water and money can Crescent 84E G1 - - B6 save each year?

Household projections below calculate Crescent 84E G1 - - B6 annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.

Computed annual water savings for Crescent 84E G1 - - B6 (1.2 gpm)

| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 1,752 gal | 1,460 gal | 2,263 gal (~$25) |
| 2 Occupants | 3,504 gal | 2,920 gal | 4,526 gal (~$50) |
| 3 Occupants | 5,256 gal | 4,380 gal | 6,789 gal (~$54–$122) |
| 4 Occupants | 7,008 gal | 5,840 gal | 9,052 gal (~$100) |

## Which EPA WaterSense fixtures match Crescent 84E G1 - - B6?

Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.

Peer faucet models with matching or lower gpm ratings

| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| [**1858 LUM211-PU**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-1858-lum211-pu/) | 1.2 gpm (Same flow) | Lumoni |
| [**Aidier ID-B3594**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-aidier-id-b3594/) | 1.2 gpm (Same flow) | WaterSense |
| [**Axor 48170xx1**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-axor-48170xx1/) | 1.2 gpm (Same flow) | Axoror One |
| [**B&K 221-015**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-b-k-221-015/) | 1.2 gpm (Same flow) | Lavatory Faucet |
| [**B&K 222-311H**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-b-k-222-311h/) | 1.2 gpm (Same flow) | Lavatory Faucet |

## How much does Crescent 84E G1 - - B6 save at your local water rate?

Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.

Household Occupants

Water + Sewer Rate ($ / 1k gal)

## What plumbing or duct constraints rule out Crescent 84E G1 - - B6?

Compare where Crescent 84E G1 - - B6 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Low static water supply pressure <30 PSI

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Claiming utility rebates across 200 U.S. WaterSense programs
- **Suited to:** Lowering household draw to 1,752 gal/person/yr

## What key rules and numbers govern Crescent 84E G1 - - B6?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Crescent 84E G1 - - B6.

### How do 133 WaterSense rebate programs treat Crescent 84E G1 - - B6?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Crescent 84E G1 - - B6, itemized purchase invoices, and residential installation addresses.

### How does Crescent 84E G1 - - B6 perform relative to the EPA WaterSense category median?

Among certified WaterSense faucets, the national median stands at 1.2 gpm. At 1.2 gpm, Crescent 84E G1 - - B6 sits equal to the category median while clearing federal WaterSense caps.

### How much does a 3-resident family save yearly switching to Crescent 84E G1 - - B6?

At $11 per 1,000 gallons, a 3-person household conserving 24,528 gallons/yr with Crescent 84E G1 - - B6 trims roughly $270 annually off water and sewer utility bills.

### What anti-scald valve standard pairs with Crescent 84E G1 - - B6?

Pairing Crescent 84E G1 - - B6 (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

### How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

### Does installing Crescent 84E G1 - - B6 require a municipal plumbing permit?

Like-for-like swaps using Crescent 84E G1 - - B6 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

### Why upgrade a 4.0 gpm fixture to Crescent 84E G1 - - B6 at 1.2 gpm?

Swapping a 4.0 gpm unit for Crescent 84E G1 - - B6 slashes water draw 70.0% (8,176 gal/person/yr), beating 2.2 gpm federal EPAct standards by 45.5%.

### When can Crescent 84E G1 - - B6 (1.2 gpm) underperform in an older bathroom?

Skip Crescent 84E G1 - - B6 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

## Which guides and calculators connect next to Crescent 84E G1 - - B6?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Crescent 84E G1 - - B6.

- [Compare WaterSense 1.28 gpf vs 3.5 gpf toilets](https://siematic-charleston.com/compare/epa-watersense-128-gpf-vs-35-gpf-legacy-toilet/)
- [Browse all faucets in registry](https://siematic-charleston.com/watersense-fixtures/faucets/)
- [Browse 200 U.S. WaterSense utility rebates](https://siematic-charleston.com/rebates/)
- [Crosswater Ltd US-WP120WNX WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-crosswater-ltd-us-wp120wnx/)
- [Danco, Inc. 10495 WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-danco-inc-10495/)
- [Conservation Management Solutions 50485xx WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-conservation-management-solutions-50485xx/)

## Sources

1. [EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets)](https://lookforwatersense.epa.gov/products/) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
2. [EPA WaterSense Utility Rebate Finder API](https://www.epa.gov/watersense/rebate-finder) — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Check U.S. WaterSense Rebates

See all 51 states and 200 U.S. utility rebate programs.
[Open Rebate Directory](https://siematic-charleston.com/rebates/)
