title: "Fratelli Fantini S.p.A A107WU WaterSense Faucet (1.2 gpm)"
url: https://siematic-charleston.com/watersense-fixtures/faucet/faucet-fratelli-fantini-s-p-a-a107wu/
description: "EPA WaterSense faucet Fratelli Fantini S.p.A A107WU: 1.2 gpm (45.5% under EPAct 1992), 2,263 gal/person/yr savings and 5 peers."
---

#  Fratelli Fantini S.p.A A107WU WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Fratelli Fantini S.p.A (1 SKU)

Verified Specification Summary

Certified under EPA WaterSense, Fratelli Fantini S.p.A A107WU tests at 1.2 gpm (#1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets), trimming 45.5% off the 2.2 gpm federal cap while cutting 3-person household draw by ~6,789 gal/yr versus 2.75 gpm fixtures. Compare EPA WaterSense certified flow metrics for Fratelli Fantini S.p.A A107WU WaterSense Faucet, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

- **Certified Flow**: 1.2 gpm

- **vs. EPAct 1992**: -45.5% (2.2 gpm)

- **Annual Draw (1 Pers.)**: 1,752 gal/yr

- **Annual Saved vs. Legacy**: 2,263 gal/person

- **Brand EPA Count**: 49 faucets

- **Series / Variants**: A107WU (1)

WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

## What does Fratelli Fantini S.p.A A107WU Benchmark & Water Budget show?

Efficiency check: certified at 1.2 gpm, Fratelli Fantini S.p.A A107WU trims 45.5% under federal 2.2 gpm caps; #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets.

Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Fratelli Fantini S.p.A holds 49 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).

## Where does Fratelli Fantini S.p.A A107WU sit on the EPA WaterSense faucet flow curve?

Comparing Fratelli Fantini S.p.A A107WU (1.20 gpm) against federal EPAct (2.2 gpm) and legacy (2.75 gpm) baselines shows immediate per-use conservation.

## How do subfloor levelness and rough-in height protect Fratelli Fantini S.p.A A107WU?

Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What official WaterSense figures verify Fratelli Fantini S.p.A A107WU?

Examine Fratelli Fantini S.p.A A107WU certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Registry Share** | Fratelli Fantini S.p.A (49 certified) | EPA WaterSense Partner |
| **Model Number / Series** | A107WU | Certified Series (1 finish variants) |
| **Rated Consumption** | 1.2 gpm | Category median 1.2 gpm (n=22,471 rated) |
| **Shower / Faucet Pairing** | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |

## What annual utility savings does Fratelli Fantini S.p.A A107WU deliver?

Compare 1-to-4-person household water use with Fratelli Fantini S.p.A A107WU against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.

Computed annual water savings for Fratelli Fantini S.p.A A107WU (1.2 gpm)

| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 1,752 gal | 1,460 gal | 2,263 gal (~$25) |
| 2 Occupants | 3,504 gal | 2,920 gal | 4,526 gal (~$50) |
| 3 Occupants | 5,256 gal | 4,380 gal | 6,789 gal (~$54–$122) |
| 4 Occupants | 7,008 gal | 5,840 gal | 9,052 gal (~$100) |

## What alternative WaterSense models compare to Fratelli Fantini S.p.A A107WU?

Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.

Peer faucet models with matching or lower gpm ratings

| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| [**1858 LUM211-PU**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-1858-lum211-pu/) | 1.2 gpm (Same flow) | Lumoni |
| [**Aidier ID-B3594**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-aidier-id-b3594/) | 1.2 gpm (Same flow) | WaterSense |
| [**Axor 48170xx1**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-axor-48170xx1/) | 1.2 gpm (Same flow) | Axoror One |
| [**B&K 221-015**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-b-k-221-015/) | 1.2 gpm (Same flow) | Lavatory Faucet |
| [**B&K 222-311H**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-b-k-222-311h/) | 1.2 gpm (Same flow) | Lavatory Faucet |

## What will Fratelli Fantini S.p.A A107WU save on your annual water bill?

Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.

Household Occupants

Water + Sewer Rate ($ / 1k gal)

## Does Fratelli Fantini S.p.A A107WU suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Fratelli Fantini S.p.A A107WU for your remodel.

### Limitations & Who Should Skip

- Existing shower valve lacks ASSE 1016 pressure balancing

### Best-Fit Homeowner Profiles

- **Strong scenario:** Meeting 2.2 gpm federal & stricter WaterSense caps
- **Best application:** Targeting ~$75/yr utility savings (3-person home)

## Which homeowner questions come up most for Fratelli Fantini S.p.A A107WU?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Fratelli Fantini S.p.A A107WU.

### What efficiency edge separates Fratelli Fantini S.p.A A107WU from legacy and EPAct models?

Certified at 1.2 gpm, Fratelli Fantini S.p.A A107WU achieves 45.5% savings against EPAct 1992 (2.2 gpm) and 70.0% savings against 4.0 gpm fixtures, 8,176 gallons per occupant yearly.

### What supply pressure checks protect Fratelli Fantini S.p.A A107WU spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.2 gpm trim.

### Does Fratelli Fantini S.p.A A107WU qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes Fratelli Fantini S.p.A A107WU eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

### Where does Fratelli Fantini S.p.A A107WU rank against other certified faucets?

Rated at 1.2 gpm, Fratelli Fantini S.p.A A107WU measures equal to the 1.2 gpm WaterSense faucet median across thousands of EPA-listed residential fixtures.

### Does Fratelli Fantini S.p.A A107WU cut utility costs noticeably for a 3-person household?

Yes: cutting 24,528 gallons/yr relative to 4.0 gpm hardware translates to ~$270/yr in combined water/sewer savings at $11/1k gal.

### What anti-scald valve standard pairs with Fratelli Fantini S.p.A A107WU?

Pairing Fratelli Fantini S.p.A A107WU (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

### How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

### Does installing Fratelli Fantini S.p.A A107WU require a municipal plumbing permit?

Like-for-like swaps using Fratelli Fantini S.p.A A107WU on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

## Where can you explore more benchmarks around Fratelli Fantini S.p.A A107WU?

Use the related reference pages and estimators below to cross-check Fratelli Fantini S.p.A A107WU against state labor wages, WaterSense rebates, and federal grant rules.

- [Compare WaterSense 1.28 gpf vs 3.5 gpf toilets](https://siematic-charleston.com/compare/epa-watersense-128-gpf-vs-35-gpf-legacy-toilet/)
- [Browse all faucets in registry](https://siematic-charleston.com/watersense-fixtures/faucets/)
- [Browse 200 U.S. WaterSense utility rebates](https://siematic-charleston.com/rebates/)
- [Freendo 192-6401 WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-freendo-192-6401/)
- [FRESCA FFT3071 WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-fresca-fft3071/)
- [FRANZ VIEGENER FV201/J2D WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-franz-viegener-fv201-j2d/)

## Sources

1. [EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets)](https://lookforwatersense.epa.gov/products/) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
2. [EPA WaterSense Utility Rebate Finder API](https://www.epa.gov/watersense/rebate-finder) — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Check U.S. WaterSense Rebates

See all 51 states and 200 U.S. utility rebate programs.
[Open Rebate Directory](https://siematic-charleston.com/rebates/)