---
title: "Mirabelle MIRWSCPR800 WaterSense Faucet (1.2 gpm) | GradeMark"
url: https://siematic-charleston.com/watersense-fixtures/faucet/faucet-mirabelle-mirwscpr800/
description: "EPA WaterSense faucet Mirabelle MIRWSCPR800: 1.2 gpm (45.5% under EPAct 1992), 2,263 gal/person/yr savings and 5 peers. Verified US agency benchmarks."
---

#  Mirabelle MIRWSCPR800 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Provincetown (3 SKUs)

Verified Specification Summary

Listed in EPA WaterSense files at 1.2 gpm, Mirabelle MIRWSCPR800 achieves #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets and lowers household water use ~6,789 gal/yr (3 residents) against pre-1994 2.75 gpm fixtures. Compare EPA WaterSense certified flow metrics for Mirabelle MIRWSCPR800 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

- **Certified Flow**: 1.2 gpm

- **vs. EPAct 1992**: -45.5% (2.2 gpm)

- **Annual Draw (1 Pers.)**: 1,752 gal/yr

- **Annual Saved vs. Legacy**: 2,263 gal/person

- **Brand EPA Count**: 21 faucets

- **Series / Variants**: MIRWSCPR800 (3)

WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

## What does Mirabelle MIRWSCPR800 Benchmark & Water Budget show?

Certified discharge for Mirabelle MIRWSCPR800 (Provincetown) measures 1.2 gpm (aggressive sub-1.6 gpm conservation tier), standing #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets against the 2.2 gpm standard.

Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Mirabelle holds 21 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as Liberty Utilities - Arizona (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).

## Does Mirabelle MIRWSCPR800 beat the 1.2 gpm WaterSense faucet median?

Certified at 1.20 gpm, Mirabelle MIRWSCPR800 sits well under EPAct 1992 limits (2.2 gpm) across 22,471 EPA-registered faucets.

## Why check closet flange height and L/360 stiffness around Mirabelle MIRWSCPR800?

Checking framing deflection (L/360) and finished tile-to-flange elevation before fixture mounting eliminates wobble and concealed floor leaks.

Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

## Where does Mirabelle MIRWSCPR800 fit in EPA WaterSense files?

Review certified water flow, brand lineup breadth, and ASSE 1016 valve or IPC closet flange pairing guidelines for Mirabelle MIRWSCPR800.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Registry Share** | Mirabelle (21 certified) | EPA WaterSense Partner |
| **Model Number / Series** | MIRWSCPR800 | Provincetown (3 finish variants) |
| **Rated Consumption** | 1.2 gpm | Category median 1.2 gpm (n=22,471 rated) |
| **Shower / Faucet Pairing** | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |

## Which 3 finish and trim SKUs share the Mirabelle MIRWSCPR800 WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 3 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Mirabelle MIRWSCPR800 (3 total certified variants)

| Certified Finish SKU | Verified Flow | Series Designation |
|---|---|---|
| MIRWSCPR800* | 1.2 gpm | Provincetown |
| MIRWSCPR400* | 1.2 gpm | Provincetown |
| MIRWSCPR100* | 1.2 gpm | Provincetown |

## Does Mirabelle MIRWSCPR800 lower water bills for larger households?

Review computed annual water totals for 1 to 4 residents comparing Mirabelle MIRWSCPR800 certified consumption with older pre-1994 residential plumbing hardware.

Computed annual water savings for Mirabelle MIRWSCPR800 (1.2 gpm)

| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 1,752 gal | 1,460 gal | 2,263 gal (~$25) |
| 2 Occupants | 3,504 gal | 2,920 gal | 4,526 gal (~$50) |
| 3 Occupants | 5,256 gal | 4,380 gal | 6,789 gal (~$54–$122) |
| 4 Occupants | 7,008 gal | 5,840 gal | 9,052 gal (~$100) |

## How do similar WaterSense brands compare with Mirabelle MIRWSCPR800?

Comparable certified models listed below share Mirabelle MIRWSCPR800 category standards while offering alternative brand warranties and rough-in configurations.

Peer faucet models with matching or lower gpm ratings

| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| [**1858 LUM211-PU**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-1858-lum211-pu/) | 1.2 gpm (Same flow) | Lumoni |
| [**Aidier ID-B3594**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-aidier-id-b3594/) | 1.2 gpm (Same flow) | WaterSense |
| [**Axor 48170xx1**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-axor-48170xx1/) | 1.2 gpm (Same flow) | Axoror One |
| [**B&K 221-015**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-b-k-221-015/) | 1.2 gpm (Same flow) | Lavatory Faucet |
| [**B&K 222-311H**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-b-k-222-311h/) | 1.2 gpm (Same flow) | Lavatory Faucet |

## How do local water rates change Mirabelle MIRWSCPR800 savings?

Use the local browser estimator below with your city water-sewer rate and household size to quantify Mirabelle MIRWSCPR800 yearly utility impact.

Household Occupants

Water + Sewer Rate ($ / 1k gal)

## Which bath layouts should avoid specifying Mirabelle MIRWSCPR800?

Match Mirabelle MIRWSCPR800 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Low static water supply pressure <30 PSI

### Best-Fit Homeowner Profiles

- **Best for:** Claiming utility rebates across 200 U.S. WaterSense programs
- **Optimal use:** Lowering household draw to 1,752 gal/person/yr

## What should homeowners verify first about Mirabelle MIRWSCPR800?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Mirabelle MIRWSCPR800.

### Does Mirabelle MIRWSCPR800 cut utility costs noticeably for a 3-person household?

Yes: cutting 24,528 gallons/yr relative to 4.0 gpm hardware translates to ~$270/yr in combined water/sewer savings at $11/1k gal.

### What anti-scald valve standard pairs with Mirabelle MIRWSCPR800?

Pairing Mirabelle MIRWSCPR800 (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

### How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

### Does installing Mirabelle MIRWSCPR800 require a municipal plumbing permit?

Like-for-like swaps using Mirabelle MIRWSCPR800 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

### How does Mirabelle MIRWSCPR800 cut household water draw versus 1992 federal rules?

Delivering 1.2 gpm, Mirabelle MIRWSCPR800 trims 2,920 gal/person/yr below 2.2 gpm EPAct caps (45.5% reduction) and 8,176 gal/person/yr under 4.0 gpm legacy fixtures.

### What supply pressure checks protect Mirabelle MIRWSCPR800 spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.2 gpm trim.

### Does Mirabelle MIRWSCPR800 qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes Mirabelle MIRWSCPR800 eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

### Where does Mirabelle MIRWSCPR800 rank against other certified faucets?

Rated at 1.2 gpm, Mirabelle MIRWSCPR800 measures equal to the 1.2 gpm WaterSense faucet median across thousands of EPA-listed residential fixtures.

## Which GradeMark tools pair best with Mirabelle MIRWSCPR800?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Mirabelle MIRWSCPR800.

- [Compare WaterSense 1.28 gpf vs 3.5 gpf toilets](https://siematic-charleston.com/compare/epa-watersense-128-gpf-vs-35-gpf-legacy-toilet/)
- [Browse all faucets in registry](https://siematic-charleston.com/watersense-fixtures/faucets/)
- [Browse 200 U.S. WaterSense utility rebates](https://siematic-charleston.com/rebates/)
- [Miseno MNO721L WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-miseno-mno721l/)
- [MJF W-A-B-C-D-E-1.0GPM WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-mjf-w-a-b-c-d-e-1-0gpm/)
- [Matco-Norca PD-550MB WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-matco-norca-pd-550mb/)

## Sources

1. [EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets)](https://lookforwatersense.epa.gov/products/) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
2. [EPA WaterSense Utility Rebate Finder API](https://www.epa.gov/watersense/rebate-finder) — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Check U.S. WaterSense Rebates

See all 51 states and 200 U.S. utility rebate programs.
[Open Rebate Directory](https://siematic-charleston.com/rebates/)
