---
title: "USCT U175A29CCH WaterSense Faucet (1.5 gpm) | GradeMark"
url: https://siematic-charleston.com/watersense-fixtures/faucet/faucet-usct-u175a29cch/
description: "EPA WaterSense faucet USCT U175A29CCH: 1.5 gpm (31.8% under EPAct 1992), 1,825 gal/person/yr savings and 5 peers. Verified US agency benchmarks."
---

#  USCT U175A29CCH WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · USCT (1 SKU)

Verified Specification Summary

The USCT U175A29CCH is an EPA WaterSense faucet certified at 1.5 gpm, 31.8% below EPAct 1992 (2.2 gpm) and #15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm. A 3-person household saves ~5,475 gallons/yr replacing a 2.75 gpm legacy fixture. Compare EPA WaterSense certified flow metrics for USCT U175A29CCH WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

- **Certified Flow**: 1.5 gpm

- **vs. EPAct 1992**: -31.8% (2.2 gpm)

- **Annual Draw (1 Pers.)**: 2,190 gal/yr

- **Annual Saved vs. Legacy**: 1,825 gal/person

- **Brand EPA Count**: 5 faucets

- **Series / Variants**: U175A29CCH (1)

WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

## What does USCT U175A29CCH Benchmark & Water Budget show?

Flow standing: USCT U175A29CCH operates at 1.5 gpm (aggressive sub-1.6 gpm conservation tier), #15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm (0.30 gpm higher-flow than the 1.20 gpm median), cutting 31.8% off EPAct 1992 (2.2 gpm).

Pair this 1.5 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: USCT holds 5 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~5,475 gallons/yr—roughly $44/yr in low-tariff towns ($8/1k gal), $60/yr at national averages ($11/1k gal), or $99/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: AM Conservation Group, Inc. FA012CPB1WS (1.5 gpm) and Amazon 90457.05 (1.5 gpm).

## How does USCT U175A29CCH compare to EPAct 1992 and legacy gpm rates?

Tested at 1.50 gpm, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (2.2 gpm) and pre-1994 legacy units (2.75 gpm).

## What floor flatness and flange clearances pair with USCT U175A29CCH?

Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.

Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

## Which EPA WaterSense test specs apply to USCT U175A29CCH?

Certified EPA WaterSense records for USCT U175A29CCH verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Registry Share** | USCT (5 certified) | EPA WaterSense Partner |
| **Model Number / Series** | U175A29CCH | Certified Series (1 finish variants) |
| **Rated Consumption** | 1.5 gpm | Category median 1.2 gpm (n=22,471 rated) |
| **Shower / Faucet Pairing** | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |

## How much water and money can USCT U175A29CCH save each year?

Household projections below calculate USCT U175A29CCH annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.

Computed annual water savings for USCT U175A29CCH (1.5 gpm)

| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 2,190 gal | 1,022 gal | 1,825 gal (~$20) |
| 2 Occupants | 4,380 gal | 2,044 gal | 3,650 gal (~$40) |
| 3 Occupants | 6,570 gal | 3,066 gal | 5,475 gal (~$44–$99) |
| 4 Occupants | 8,760 gal | 4,088 gal | 7,300 gal (~$80) |

## Which EPA WaterSense fixtures match USCT U175A29CCH?

Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.

Peer faucet models with matching or lower gpm ratings

| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| [**AM Conservation Group, Inc. FA012CPB1WS**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-am-conservation-group-inc-fa012cpb1ws/) | 1.5 gpm (Same flow) | WaterSense |
| [**Amazon 90457.05**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-amazon-90457-05/) | 1.5 gpm (Same flow) | WaterSense |
| [**Aqueous™, Estora™ or Homewerks Worldwide 20-B41CY-Z**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-aqueous-estora-or-homewerks-worldwide-20-b41cy-z/) | 1.5 gpm (Same flow) | WaterSense |
| [**Aqueous™, Estora™ or Homewerks Worldwide 30-B41WN-Z**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-aqueous-estora-or-homewerks-worldwide-30-b41wn-z/) | 1.5 gpm (Same flow) | WaterSense |
| [**Brookfield 192-8268**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-brookfield-192-8268/) | 1.5 gpm (Same flow) | CMI 3252C Chrome Two Handle Deluxe... |

## How much does USCT U175A29CCH save at your local water rate?

Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.

Household Occupants

Water + Sewer Rate ($ / 1k gal)

## When does USCT U175A29CCH fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering USCT U175A29CCH.

### Limitations & Who Should Skip

- Low static water supply pressure <30 PSI

### Best-Fit Homeowner Profiles

- **Recommended when:** Claiming utility rebates across 200 U.S. WaterSense programs
- **Target scenario:** Lowering household draw to 2,190 gal/person/yr

## What key rules and numbers govern USCT U175A29CCH?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting USCT U175A29CCH.

### How much does a 3-resident family save yearly switching to USCT U175A29CCH?

At $11 per 1,000 gallons, a 3-person household conserving 21,900 gallons/yr with USCT U175A29CCH trims roughly $241 annually off water and sewer utility bills.

### What anti-scald valve standard pairs with USCT U175A29CCH?

Pairing USCT U175A29CCH (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

### How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

### Does installing USCT U175A29CCH require a municipal plumbing permit?

Like-for-like swaps using USCT U175A29CCH on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

### What annual gallon reduction does USCT U175A29CCH achieve over older plumbing?

Testing at 1.5 gpm, USCT U175A29CCH uses 62.5% less water than 4.0 gpm pre-1994 models (31.8% below 2.2 gpm EPAct), conserving 7,300 gallons per resident each year.

### When can USCT U175A29CCH (1.5 gpm) underperform in an older bathroom?

Skip USCT U175A29CCH without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

### How do 133 WaterSense rebate programs treat USCT U175A29CCH?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like USCT U175A29CCH, itemized purchase invoices, and residential installation addresses.

### How does USCT U175A29CCH perform relative to the EPA WaterSense category median?

Among certified WaterSense faucets, the national median stands at 1.2 gpm. At 1.5 gpm, USCT U175A29CCH sits slightly above the category median while clearing federal WaterSense caps.

## Which guides and calculators connect next to USCT U175A29CCH?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for USCT U175A29CCH.

- [Compare WaterSense 1.28 gpf vs 3.5 gpf toilets](https://siematic-charleston.com/compare/epa-watersense-128-gpf-vs-35-gpf-legacy-toilet/)
- [Browse all faucets in registry](https://siematic-charleston.com/watersense-fixtures/faucets/)
- [Browse 200 U.S. WaterSense utility rebates](https://siematic-charleston.com/rebates/)
- [VALU+ FW6AC062 WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-valu-fw6ac062/)
- [Vancomp 2004-L-XXXXXX-XX-1.0 WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-vancomp-2004-l-xxxxxx-xx-1-0/)
- [Ultra Faucets™ UF8430X WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-ultra-faucets-uf8430x/)

## Sources

1. [EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets)](https://lookforwatersense.epa.gov/products/) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
2. [EPA WaterSense Utility Rebate Finder API](https://www.epa.gov/watersense/rebate-finder) — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Check U.S. WaterSense Rebates

See all 51 states and 200 U.S. utility rebate programs.
[Open Rebate Directory](https://siematic-charleston.com/rebates/)
