title: "Water Nymph A0505(1)-(2)45(4)(5)(6) WaterSense Faucet (1.2 gpm)"
url: https://siematic-charleston.com/watersense-fixtures/faucet/faucet-water-nymph-a0505-1-2-45-4-5-6/
description: "EPA WaterSense faucet Water Nymph A0505(1)-(2)45(4)(5)(6): 1.2 gpm (45.5% under EPAct 1992), 2,263 gal/person/yr savings and 5 peers."
---

#  Water Nymph A0505(1)-(2)45(4)(5)(6) WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Water Nymph (1 SKU)

Verified Specification Summary

The Water Nymph A0505(1)-(2)45(4)(5)(6) is an EPA WaterSense faucet certified at 1.2 gpm, 45.5% below EPAct 1992 (2.2 gpm) and #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets. A 3-person household saves ~6,789 gallons/yr replacing a 2.75 gpm legacy fixture. Compare EPA WaterSense certified flow metrics for Water Nymph A0505(1)-(2)45(4)(5)(6) WaterSense Faucet, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

- **Certified Flow**: 1.2 gpm

- **vs. EPAct 1992**: -45.5% (2.2 gpm)

- **Annual Draw (1 Pers.)**: 1,752 gal/yr

- **Annual Saved vs. Legacy**: 2,263 gal/person

- **Brand EPA Count**: 57 faucets

- **Series / Variants**: A0505(1)-(2)45(4)(5)(6) (1)

WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

## What does Water Nymph A0505(1)-(2)45(4)(5)(6) Benchmark & Water Budget show?

Flow standing: Water Nymph A0505(1)-(2)45(4)(5)(6) operates at 1.2 gpm (aggressive sub-1.6 gpm conservation tier), #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets, cutting 45.5% off EPAct 1992 (2.2 gpm).

Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Water Nymph holds 57 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as Big Bear Lake Department of Water and Power (CA) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).

## How does Water Nymph A0505(1)-(2)45(4)(5)(6) compare to EPAct 1992 and legacy gpm rates?

Tested at 1.20 gpm, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (2.2 gpm) and pre-1994 legacy units (2.75 gpm).

## What floor flatness and flange clearances pair with Water Nymph A0505(1)-(2)45(4)(5)(6)?

Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.

Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

## Which EPA WaterSense test specs apply to Water Nymph A0505(1)-(2)45(4)(5)(6)?

Certified EPA WaterSense records for Water Nymph A0505(1)-(2)45(4)(5)(6) verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Registry Share** | Water Nymph (57 certified) | EPA WaterSense Partner |
| **Model Number / Series** | A0505(1)-(2)45(4)(5)(6) | Certified Series (1 finish variants) |
| **Rated Consumption** | 1.2 gpm | Category median 1.2 gpm (n=22,471 rated) |
| **Shower / Faucet Pairing** | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |

## How much water and money can Water Nymph A0505(1)-(2)45(4)(5)(6) save each year?

Household projections below calculate Water Nymph A0505(1)-(2)45(4)(5)(6) annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.

Computed annual water savings for Water Nymph A0505(1)-(2)45(4)(5)(6) (1.2 gpm)

| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 1,752 gal | 1,460 gal | 2,263 gal (~$25) |
| 2 Occupants | 3,504 gal | 2,920 gal | 4,526 gal (~$50) |
| 3 Occupants | 5,256 gal | 4,380 gal | 6,789 gal (~$54–$122) |
| 4 Occupants | 7,008 gal | 5,840 gal | 9,052 gal (~$100) |

## Which EPA WaterSense fixtures match Water Nymph A0505(1)-(2)45(4)(5)(6)?

Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.

Peer faucet models with matching or lower gpm ratings

| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| [**1858 LUM211-PU**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-1858-lum211-pu/) | 1.2 gpm (Same flow) | Lumoni |
| [**Aidier ID-B3594**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-aidier-id-b3594/) | 1.2 gpm (Same flow) | WaterSense |
| [**Axor 48170xx1**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-axor-48170xx1/) | 1.2 gpm (Same flow) | Axoror One |
| [**B&K 221-015**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-b-k-221-015/) | 1.2 gpm (Same flow) | Lavatory Faucet |
| [**B&K 222-311H**](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-b-k-222-311h/) | 1.2 gpm (Same flow) | Lavatory Faucet |

## How much does Water Nymph A0505(1)-(2)45(4)(5)(6) save at your local water rate?

Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.

Household Occupants

Water + Sewer Rate ($ / 1k gal)

## Who should not install Water Nymph A0505(1)-(2)45(4)(5)(6) in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Water Nymph A0505(1)-(2)45(4)(5)(6) for residential use.

### Limitations & Who Should Skip

- Low static water supply pressure <30 PSI

### Best-Fit Homeowner Profiles

- **Ideal fit:** Claiming utility rebates across 200 U.S. WaterSense programs
- **Primary match:** Lowering household draw to 1,752 gal/person/yr

## What key rules and numbers govern Water Nymph A0505(1)-(2)45(4)(5)(6)?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Water Nymph A0505(1)-(2)45(4)(5)(6).

### What annual dollar savings can a 3-person home expect with Water Nymph A0505(1)-(2)45(4)(5)(6)?

Upgrading a 4.0 gpm legacy fixture to Water Nymph A0505(1)-(2)45(4)(5)(6) saves ~24,528 gallons yearly for three occupants, about $270/yr at $11 per 1,000 gallons combined water and sewer.

### What anti-scald valve standard pairs with Water Nymph A0505(1)-(2)45(4)(5)(6)?

Pairing Water Nymph A0505(1)-(2)45(4)(5)(6) (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

### How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

### Does installing Water Nymph A0505(1)-(2)45(4)(5)(6) require a municipal plumbing permit?

Like-for-like swaps using Water Nymph A0505(1)-(2)45(4)(5)(6) on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

### How much water does Water Nymph A0505(1)-(2)45(4)(5)(6) save compared with EPAct 1992 and pre-1994 fixtures?

Rated at 1.2 gpm, Water Nymph A0505(1)-(2)45(4)(5)(6) cuts 45.5% below the 2.2 gpm EPAct 1992 ceiling and 70.0% under 4.0 gpm legacy units, saving 8,176 gal/person/yr (2,920 vs EPAct).

### Who should NOT install Water Nymph A0505(1)-(2)45(4)(5)(6) without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.2 gpm faucet.

### Can homeowners claim utility rebates when installing Water Nymph A0505(1)-(2)45(4)(5)(6)?

Because Water Nymph A0505(1)-(2)45(4)(5)(6) holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

### Is Water Nymph A0505(1)-(2)45(4)(5)(6) leaner than typical WaterSense faucet models?

Compared with the 1.2 gpm WaterSense faucet median, Water Nymph A0505(1)-(2)45(4)(5)(6)'s 1.2 gpm rating places it equal to category norms inside EPA conservation limits.

## Which guides and calculators connect next to Water Nymph A0505(1)-(2)45(4)(5)(6)?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Water Nymph A0505(1)-(2)45(4)(5)(6).

- [Compare WaterSense 1.28 gpf vs 3.5 gpf toilets](https://siematic-charleston.com/compare/epa-watersense-128-gpf-vs-35-gpf-legacy-toilet/)
- [Browse all faucets in registry](https://siematic-charleston.com/watersense-fixtures/faucets/)
- [Browse 200 U.S. WaterSense utility rebates](https://siematic-charleston.com/rebates/)
- [Waterworks FLLS30X WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-waterworks-flls30x/)
- [Whitefalls 201096N WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-whitefalls-201096n/)
- [Waltec 82234 WaterSense Faucet Specifications](https://siematic-charleston.com/watersense-fixtures/faucet/faucet-waltec-82234/)

## Sources

1. [EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets)](https://lookforwatersense.epa.gov/products/) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
2. [EPA WaterSense Utility Rebate Finder API](https://www.epa.gov/watersense/rebate-finder) — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Check U.S. WaterSense Rebates
