#  Delta Commercial T13H333 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Delta Commercial (2 SKUs)

Verified Specification Summary

Operating at 1.5 gpm, the Delta Commercial T13H333 showerhead beats 1992 EPAct rules (2.5 gpm) by 40.0% (#559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads), saving a 3-resident home ~17,520 gallons annually compared to 3.5 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for Delta Commercial T13H333 WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

- **Certified Flow**: 1.5 gpm

- **vs. EPAct 1992**: -40.0% (2.5 gpm)

- **Annual Draw (1 Pers.)**: 4,380 gal/yr

- **Annual Saved vs. Legacy**: 5,840 gal/person

- **Brand EPA Count**: 98 showerheads

- **Series / Variants**: T13H333 (2)

WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

## What does Delta Commercial T13H333 Benchmark & Water Budget show?

WaterSense benchmark: Delta Commercial series T13H333 verifies 1.5 gpm delivery, scoring 40.0% leaner than EPAct 1992 (2.5 gpm) at #559 of 18,544 certified showerheads; most water-efficient 18.0% of 18,544 certified showerheads, lower-flow than 82.0% of certified showerheads (0.25 gpm lower-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.5 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Delta Commercial holds 98 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~17,520 gallons/yr—roughly $140/yr in low-tariff towns ($8/1k gal), $193/yr at national averages ($11/1k gal), or $315/yr in high-rate cities ($18/1k gal). Regional utilities such as Liberty Utilities - Arizona (AZ) list active rebates among 200 U.S. programs. Closest alternatives: Acorn Controls CSH-WSC (1.5 gpm) and ACORN CSH-WSA (1.5 gpm).

## How much leaner is Delta Commercial T13H333 than pre-1994 3.5 gpm plumbing?

Flow distribution bars contrast Delta Commercial T13H333 (1.50 gpm) directly with the 1.75 gpm WaterSense median and 3.5 gpm older fixtures.

## Which framing and flange tolerances matter before installing Delta Commercial T13H333?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

## How does Delta Commercial T13H333 compare to WaterSense category caps?

Each specification row below documents Delta Commercial T13H333 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Registry Share** | Delta Commercial (98 certified) | EPA WaterSense Partner |
| **Model Number / Series** | T13H333 | Certified Series (2 finish variants) |
| **Rated Consumption** | 1.5 gpm | Category median 1.75 gpm (n=18,544 rated) |
| **Shower / Faucet Pairing** | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |

## Which 2 finish and trim SKUs share the Delta Commercial T13H333 WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 1 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Delta Commercial T13H333 (2 total certified variants)

| Certified Finish SKU | Verified Flow | Series Designation |
|---|---|---|
| T13H333-* | 1.5 gpm | Shared Series Spec |

## How many gallons per year does Delta Commercial T13H333 cut?

Calculated annual water budgets below quantify Delta Commercial T13H333 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for Delta Commercial T13H333 (1.5 gpm)

| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 4,380 gal | 2,920 gal | 5,840 gal (~$64) |
| 2 Occupants | 8,760 gal | 5,840 gal | 11,680 gal (~$128) |
| 3 Occupants | 13,140 gal | 8,760 gal | 17,520 gal (~$140–$315) |
| 4 Occupants | 17,520 gal | 11,680 gal | 23,360 gal (~$257) |

## Which competing models share Delta Commercial T13H333 flow tier?

Review five peer WaterSense units matching Delta Commercial T13H333 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer showerhead models with matching or lower gpm ratings

| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| [**Acorn Controls CSH-WSC**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-acorn-controls-csh-wsc/) | 1.5 gpm (Same flow) | WaterSense |
| [**ACORN CSH-WSA**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-acorn-csh-wsa/) | 1.5 gpm (Same flow) | WaterSense |
| [**Aquacubic ASH8469**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-aquacubic-ash8469/) | 1.5 gpm (Same flow) | WaterSense |
| [**California Faucet SH-04T.15**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-california-faucet-sh-04t-15-zz/) | 1.5 gpm (Same flow) | WaterSense |
| [**Chi Liu CL-01627-2**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-chi-liu-cl-01627-2/) | 1.5 gpm (Same flow) | WaterSense |

## Can you estimate Delta Commercial T13H333 payback in your home?

Test how many gallons and dollars Delta Commercial T13H333 saves each year by entering your household residents and local water-sewer rate below.

Household Occupants

Water + Sewer Rate ($ / 1k gal)

## Where should contractors skip Delta Commercial T13H333 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta Commercial T13H333 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Multi-outlet body spray manifold exceeding single-head flow

### Best-Fit Homeowner Profiles

- **Choose this if:** Upgrading 3.5 gpm fixtures for 57.1% water reduction
- **Works well for:** Matching Delta Commercial SKU T13H333 certification on rebate forms

## How do federal and code standards apply to Delta Commercial T13H333?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta Commercial T13H333.

### How many gallons per person does Delta Commercial T13H333 save annually?

Each resident saves ~7,300 gallons yearly (62.5% drop) replacing a 4.0 gpm fixture with Delta Commercial T13H333 (1.5 gpm), or 2,920 gal/yr versus 2.5 gpm EPAct baselines.

### Who should NOT install Delta Commercial T13H333 without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.5 gpm showerhead.

### Can homeowners claim utility rebates when installing Delta Commercial T13H333?

Because Delta Commercial T13H333 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

### Is Delta Commercial T13H333 leaner than typical WaterSense showerhead models?

Compared with the 1.8 gpm WaterSense showerhead median, Delta Commercial T13H333's 1.5 gpm rating places it below category norms inside EPA conservation limits.

### What annual dollar savings can a 3-person home expect with Delta Commercial T13H333?

Upgrading a 4.0 gpm legacy fixture to Delta Commercial T13H333 saves ~21,900 gallons yearly for three occupants, about $241/yr at $11 per 1,000 gallons combined water and sewer.

### What anti-scald valve standard pairs with Delta Commercial T13H333?

Pairing Delta Commercial T13H333 (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

### How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

### Does installing Delta Commercial T13H333 require a municipal plumbing permit?

Like-for-like swaps using Delta Commercial T13H333 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

## What neighboring pages and tools support Delta Commercial T13H333?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Delta Commercial T13H333.

- [Compare WaterSense 1.28 gpf vs 3.5 gpf toilets](https://siematic-charleston.com/compare/epa-watersense-128-gpf-vs-35-gpf-legacy-toilet/)
- [Browse all showerheads in registry](https://siematic-charleston.com/watersense-fixtures/showerheads/)
- [Browse 200 U.S. WaterSense utility rebates](https://siematic-charleston.com/rebates/)
- [Design House 594101 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-design-house-594101/)
- [DORNBRACHT 28.679.670-xx0010 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-dornbracht-28-679-670-xx0010/)
- [Delta 52658 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-delta-52658/)

## Sources

1. [EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets)](https://lookforwatersense.epa.gov/products/) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
2. [EPA WaterSense Utility Rebate Finder API](https://www.epa.gov/watersense/rebate-finder) — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Check U.S. WaterSense Rebates

See all 51 states and 200 U.S. utility rebate programs.
[Open Rebate Directory](https://siematic-charleston.com/rebates/)