title: "Fantini 31023065U WaterSense Showerhead (1.8 gpm) | GradeMark"
url: https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-fantini-31023065u/
description: "EPA WaterSense showerhead Fantini 31023065U: 1.8 gpm (28.0% under EPAct 1992), 4,964 gal/person/yr savings and 5 peers. Verified US agency benchmarks."
---

#  Fantini 31023065U WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Fantini (1 SKU)

Verified Specification Summary

Homeowners upgrading older 3.5 gpm plumbing to Fantini 31023065U (1.8 gpm, #9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads) cut 48.6% off legacy draw, conserving ~14,892 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for Fantini 31023065U WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

- **Certified Flow**: 1.8 gpm

- **vs. EPAct 1992**: -28.0% (2.5 gpm)

- **Annual Draw (1 Pers.)**: 5,256 gal/yr

- **Annual Saved vs. Legacy**: 4,964 gal/person

- **Brand EPA Count**: 23 showerheads

- **Series / Variants**: 31023065U (1)

WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

## What does Fantini 31023065U Benchmark & Water Budget show?

Laboratory testing places Fantini 31023065U at 1.8 gpm (balanced WaterSense flow tier), saving 28.0% vs. EPAct 1992 (2.5 gpm) while ranking #9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads (0.05 gpm higher-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.8 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Fantini holds 23 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~14,892 gallons/yr—roughly $119/yr in low-tariff towns ($8/1k gal), $164/yr at national averages ($11/1k gal), or $268/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 EBD511TO (1.8 gpm) and Better Homes & Gardens BH27097026121TC (1.8 gpm).

## How do federal gpm limits contrast with Fantini 31023065U tested flow?

Each bar isolates Fantini 31023065U (1.80 gpm) relative to the EPA cap, federal EPAct 1992 standard (2.5 gpm), and pre-1994 draw.

## How does wet-zone tile prep interact with Fantini 31023065U rough-ins?

Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What plumbing standards accompany Fantini 31023065U installation?

Verify Fantini 31023065U EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Registry Share** | Fantini (23 certified) | EPA WaterSense Partner |
| **Model Number / Series** | 31023065U | Certified Series (1 finish variants) |
| **Rated Consumption** | 1.8 gpm | Category median 1.75 gpm (n=18,544 rated) |
| **Shower / Faucet Pairing** | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |

## What household water budget fits Fantini 31023065U?

Annual consumption rows below translate Fantini 31023065U certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.

Computed annual water savings for Fantini 31023065U (1.8 gpm)

| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 5,256 gal | 2,044 gal | 4,964 gal (~$55) |
| 2 Occupants | 10,512 gal | 4,088 gal | 9,928 gal (~$109) |
| 3 Occupants | 15,768 gal | 6,132 gal | 14,892 gal (~$119–$268) |
| 4 Occupants | 21,024 gal | 8,176 gal | 19,856 gal (~$218) |

## Where can buyers find alternatives to Fantini 31023065U?

Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.

Peer showerhead models with matching or lower gpm ratings

| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| [**1858 EBD511TO**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-1858-ebd511to/) | 1.8 gpm (Same flow) | Embellish |
| [**Better Homes & Gardens BH27097026121TC**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-better-homes-gardens-bh27097026121tc/) | 1.8 gpm (Same flow) | WaterSense |
| [**DANCO 12158**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-danco-12158/) | 1.8 gpm (Same flow) | WaterSense |
| [**Design House 547430**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-design-house-547430/) | 1.8 gpm (Same flow) | Madison |
| [**For Living 063-6530-2**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-for-living-063-6530-2/) | 1.8 gpm (Same flow) | WaterSense |

## What annual bill drop does Fantini 31023065U achieve for your family?

Calculate annual gallons conserved and dollar savings for Fantini 31023065U using your exact occupant count and utility tariff without submitting personal info.

Household Occupants

Water + Sewer Rate ($ / 1k gal)

## Where should contractors skip Fantini 31023065U on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Fantini 31023065U carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Existing shower valve lacks ASSE 1016 pressure balancing

### Best-Fit Homeowner Profiles

- **Choose this if:** Meeting 2.5 gpm federal & stricter WaterSense caps
- **Works well for:** Targeting ~$164/yr utility savings (3-person home)

## Which code checks and cost facts matter for Fantini 31023065U?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Fantini 31023065U.

### Is Fantini 31023065U leaner than typical WaterSense showerhead models?

Compared with the 1.8 gpm WaterSense showerhead median, Fantini 31023065U's 1.8 gpm rating places it equal to category norms inside EPA conservation limits.

### What annual dollar savings can a 3-person home expect with Fantini 31023065U?

Upgrading a 4.0 gpm legacy fixture to Fantini 31023065U saves ~19,272 gallons yearly for three occupants, about $212/yr at $11 per 1,000 gallons combined water and sewer.

### What anti-scald valve standard pairs with Fantini 31023065U?

Pairing Fantini 31023065U (1.8 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

### How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.8 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

### Does installing Fantini 31023065U require a municipal plumbing permit?

Like-for-like swaps using Fantini 31023065U on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

### How many gallons per person does Fantini 31023065U save annually?

Each resident saves ~6,424 gallons yearly (55.0% drop) replacing a 4.0 gpm fixture with Fantini 31023065U (1.8 gpm), or 2,044 gal/yr versus 2.5 gpm EPAct baselines.

### Who should NOT install Fantini 31023065U without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.8 gpm showerhead.

### Can homeowners claim utility rebates when installing Fantini 31023065U?

Because Fantini 31023065U holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

## How can you cross-check Fantini 31023065U against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Fantini 31023065U.

- [Compare WaterSense 1.28 gpf vs 3.5 gpf toilets](https://siematic-charleston.com/compare/epa-watersense-128-gpf-vs-35-gpf-legacy-toilet/)
- [Browse all showerheads in registry](https://siematic-charleston.com/watersense-fixtures/showerheads/)
- [Browse 200 U.S. WaterSense utility rebates](https://siematic-charleston.com/rebates/)
- [Ferguson MNOHS770 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-ferguson-mnohs770/)
- [First wave FW310 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-first-wave-fw310/)
- [EZ-FLO 10573 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-ez-flo-10573/)

## Sources

1. [EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets)](https://lookforwatersense.epa.gov/products/) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
2. [EPA WaterSense Utility Rebate Finder API](https://www.epa.gov/watersense/rebate-finder) — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Check U.S. WaterSense Rebates

See all 51 states and 200 U.S. utility rebate programs.
[Open Rebate Directory](https://siematic-charleston.com/rebates/)