---
title: "Franz Viegener FV126.07/87 WaterSense Showerhead (1.6 gpm)"
url: https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-franz-viegener-fv126-07-87/
description: "EPA WaterSense showerhead Franz Viegener FV126.07/87: 1.6 gpm (36.0% under EPAct 1992), 5,548 gal/person/yr savings and 5 peers."
---

#  Franz Viegener FV126.07/87 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Temple Plus showerhead (1 SKU)

Verified Specification Summary

Operating at 1.6 gpm, the Franz Viegener FV126.07/87 showerhead beats 1992 EPAct rules (2.5 gpm) by 36.0% (#3,348 of 18,544 certified showerheads; most water-efficient 18.3% of 18,544 certified showerheads, lower-flow than 81.7% of certified showerheads), saving a 3-resident home ~16,644 gallons annually compared to 3.5 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for Franz Viegener FV126.07/87 WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

- **Certified Flow**: 1.6 gpm

- **vs. EPAct 1992**: -36.0% (2.5 gpm)

- **Annual Draw (1 Pers.)**: 4,672 gal/yr

- **Annual Saved vs. Legacy**: 5,548 gal/person

- **Brand EPA Count**: 65 showerheads

- **Series / Variants**: FV126.07/87 (1)

WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

## What does Franz Viegener FV126.07/87 Benchmark & Water Budget show?

WaterSense benchmark: Franz Viegener series FV126.07/87 (Temple Plus showerhead) verifies 1.6 gpm delivery, scoring 36.0% leaner than EPAct 1992 (2.5 gpm) at #3,348 of 18,544 certified showerheads; most water-efficient 18.3% of 18,544 certified showerheads, lower-flow than 81.7% of certified showerheads (0.15 gpm lower-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.6 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Franz Viegener holds 65 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~16,644 gallons/yr—roughly $133/yr in low-tariff towns ($8/1k gal), $183/yr at national averages ($11/1k gal), or $300/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: Alsons 655 (1.6 gpm) and Aquacubic ASH7328 (1.6 gpm).

## How much leaner is Franz Viegener FV126.07/87 than pre-1994 3.5 gpm plumbing?

Flow distribution bars contrast Franz Viegener FV126.07/87 (1.60 gpm) directly with the 1.75 gpm WaterSense median and 3.5 gpm older fixtures.

## Which framing and flange tolerances matter before installing Franz Viegener FV126.07/87?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

## How does Franz Viegener FV126.07/87 compare to WaterSense category caps?

Each specification row below documents Franz Viegener FV126.07/87 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Registry Share** | Franz Viegener (65 certified) | EPA WaterSense Partner |
| **Model Number / Series** | FV126.07/87 | Temple Plus showerhead (1 finish variants) |
| **Rated Consumption** | 1.6 gpm | Category median 1.75 gpm (n=18,544 rated) |
| **Shower / Faucet Pairing** | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |

## How many gallons per year does Franz Viegener FV126.07/87 cut?

Calculated annual water budgets below quantify Franz Viegener FV126.07/87 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for Franz Viegener FV126.07/87 (1.6 gpm)

| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 4,672 gal | 2,628 gal | 5,548 gal (~$61) |
| 2 Occupants | 9,344 gal | 5,256 gal | 11,096 gal (~$122) |
| 3 Occupants | 14,016 gal | 7,884 gal | 16,644 gal (~$133–$300) |
| 4 Occupants | 18,688 gal | 10,512 gal | 22,192 gal (~$244) |

## Which competing models share Franz Viegener FV126.07/87 flow tier?

Review five peer WaterSense units matching Franz Viegener FV126.07/87 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer showerhead models with matching or lower gpm ratings

| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| [**Alsons 655**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-alsons-655/) | 1.6 gpm (Same flow) | WaterSense |
| [**Aquacubic ASH7328**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-aquacubic-ash7328/) | 1.6 gpm (Same flow) | WaterSense |
| [**Bricor B110 CH-HH**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-bricor-b110-ch-hh/) | 1.6 gpm (Same flow) | Handheld B110 |
| [**Cantrio 701.703**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-cantrio-701-703/) | 1.6 gpm (Same flow) | 8" Rain Showerhead with arm |
| [**Cantrio 815.551**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-cantrio-815-551/) | 1.6 gpm (Same flow) | Personal Hand Shower with Holder and... |

## Can you estimate Franz Viegener FV126.07/87 payback in your home?

Test how many gallons and dollars Franz Viegener FV126.07/87 saves each year by entering your household residents and local water-sewer rate below.

Household Occupants

Water + Sewer Rate ($ / 1k gal)

## Which bath layouts should avoid specifying Franz Viegener FV126.07/87?

Match Franz Viegener FV126.07/87 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Multi-outlet body spray manifold exceeding single-head flow

### Best-Fit Homeowner Profiles

- **Best for:** Upgrading 3.5 gpm fixtures for 54.3% water reduction
- **Optimal use:** Matching Franz Viegener SKU FV126.07/87 certification on rebate forms

## How do federal and code standards apply to Franz Viegener FV126.07/87?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Franz Viegener FV126.07/87.

### What supply pressure checks protect Franz Viegener FV126.07/87 spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.6 gpm trim.

### Does Franz Viegener FV126.07/87 qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes Franz Viegener FV126.07/87 eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

### Where does Franz Viegener FV126.07/87 rank against other certified showerheads?

Rated at 1.6 gpm, Franz Viegener FV126.07/87 measures below the 1.8 gpm WaterSense showerhead median across thousands of EPA-listed residential fixtures.

### Does Franz Viegener FV126.07/87 cut utility costs noticeably for a 3-person household?

Yes: cutting 21,024 gallons/yr relative to 4.0 gpm hardware translates to ~$231/yr in combined water/sewer savings at $11/1k gal.

### What anti-scald valve standard pairs with Franz Viegener FV126.07/87?

Pairing Franz Viegener FV126.07/87 (1.6 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

### How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.6 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

### Does installing Franz Viegener FV126.07/87 require a municipal plumbing permit?

Like-for-like swaps using Franz Viegener FV126.07/87 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

### How does Franz Viegener FV126.07/87 cut household water draw versus 1992 federal rules?

Delivering 1.6 gpm, Franz Viegener FV126.07/87 trims 2,628 gal/person/yr below 2.5 gpm EPAct caps (36.0% reduction) and 7,008 gal/person/yr under 4.0 gpm legacy fixtures.

## What neighboring pages and tools support Franz Viegener FV126.07/87?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Franz Viegener FV126.07/87.

- [Compare WaterSense 1.28 gpf vs 3.5 gpf toilets](https://siematic-charleston.com/compare/epa-watersense-128-gpf-vs-35-gpf-legacy-toilet/)
- [Browse all showerheads in registry](https://siematic-charleston.com/watersense-fixtures/showerheads/)
- [Browse 200 U.S. WaterSense utility rebates](https://siematic-charleston.com/rebates/)
- [FREENDO 192-6180 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-freendo-192-6180-17551/)
- [Galenpoo 1539X WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-galenpoo-1539x/)
- [For Living 063-1850 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-for-living-063-1850/)

## Sources

1. [EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets)](https://lookforwatersense.epa.gov/products/) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
2. [EPA WaterSense Utility Rebate Finder API](https://www.epa.gov/watersense/rebate-finder) — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Check U.S. WaterSense Rebates

See all 51 states and 200 U.S. utility rebate programs.
[Open Rebate Directory](https://siematic-charleston.com/rebates/)
