#  INAVAMZ 72011C WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Shower head (1 SKU)

Verified Specification Summary

Verified by EPA WaterSense at 1.75 gpm, INAVAMZ 72011C sits 30.0% under federal 2.5 gpm ceilings (#3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads) and saves ~15,330 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for INAVAMZ 72011C WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

- **Certified Flow**: 1.75 gpm

- **vs. EPAct 1992**: -30.0% (2.5 gpm)

- **Annual Draw (1 Pers.)**: 5,110 gal/yr

- **Annual Saved vs. Legacy**: 5,110 gal/person

- **Brand EPA Count**: 63 showerheads

- **Series / Variants**: 72011C (1)

WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

## What does INAVAMZ 72011C Benchmark & Water Budget show?

Under EPA WaterSense protocols, INAVAMZ 72011C (Shower head) delivers 1.75 gpm (#3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads), beating the 2.5 gpm federal ceiling by 30.0%.

Verify >=30 PSI static water pressure and pair this 1.75 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: INAVAMZ holds 63 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~15,330 gallons/yr—roughly $123/yr in low-tariff towns ($8/1k gal), $169/yr at national averages ($11/1k gal), or $276/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: allen+roth 5283486 (1.75 gpm) and Axor 38442xx1 (1.75 gpm).

## Where does INAVAMZ 72011C rank among 18,544 certified showerheads?

Review how INAVAMZ 72011C (1.75 gpm) places inside EPA WaterSense's 18,544-SKU showerhead registry alongside historical 3.5 gpm units.

## What plumbing rough-in clearances prevent leaks around INAVAMZ 72011C?

Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.

Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

## Which certified attributes define INAVAMZ 72011C performance?

Official U.S. EPA WaterSense registry entries below confirm INAVAMZ 72011C rated flow rate, model series status, and household code fit.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Registry Share** | INAVAMZ (63 certified) | EPA WaterSense Partner |
| **Model Number / Series** | 72011C | Shower head (1 finish variants) |
| **Rated Consumption** | 1.75 gpm | Category median 1.75 gpm (n=18,544 rated) |
| **Shower / Faucet Pairing** | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |

## How do INAVAMZ 72011C savings scale from 1 to 4 occupants?

Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to INAVAMZ 72011C across different household sizes.

Computed annual water savings for INAVAMZ 72011C (1.75 gpm)

| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 5,110 gal | 2,190 gal | 5,110 gal (~$56) |
| 2 Occupants | 10,220 gal | 4,380 gal | 10,220 gal (~$112) |
| 3 Occupants | 15,330 gal | 6,570 gal | 15,330 gal (~$123–$276) |
| 4 Occupants | 20,440 gal | 8,760 gal | 20,440 gal (~$225) |

## Which peer fixtures deliver flow close to INAVAMZ 72011C?

Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.

Peer showerhead models with matching or lower gpm ratings

| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| [**allen+roth 5283486**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-allen-roth-5283486/) | 1.75 gpm (Same flow) | WaterSense |
| [**Axor 38442xx1**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-axor-38442xx1/) | 1.75 gpm (Same flow) | Uno |
| [**COBBE KFSCA12102**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-cobbe-kfsca12102/) | 1.75 gpm (Same flow) | KFSCA12102 |
| [**Current 01932-T**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-current-01932-t/) | 1.75 gpm (Same flow) | WaterSense |
| [**DORNBRACHT 28.647.970-xx0010**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-dornbracht-28-647-970-xx0010/) | 1.75 gpm (Same flow) | WaterSense |

## Does INAVAMZ 72011C pay off faster in high-rate cities?

Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark INAVAMZ 72011C annual savings immediately.

Household Occupants

Water + Sewer Rate ($ / 1k gal)

## Where should contractors skip INAVAMZ 72011C on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for INAVAMZ 72011C carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Multi-outlet body spray manifold exceeding single-head flow

### Best-Fit Homeowner Profiles

- **Choose this if:** Upgrading 3.5 gpm fixtures for 50.0% water reduction
- **Works well for:** Matching INAVAMZ SKU 72011C certification on rebate forms

## Where do official rules set limits for INAVAMZ 72011C?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing INAVAMZ 72011C.

### How many gallons per person does INAVAMZ 72011C save annually?

Each resident saves ~6,570 gallons yearly (56.2% drop) replacing a 4.0 gpm fixture with INAVAMZ 72011C (1.75 gpm), or 2,190 gal/yr versus 2.5 gpm EPAct baselines.

### Who should NOT install INAVAMZ 72011C without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.75 gpm showerhead.

### Can homeowners claim utility rebates when installing INAVAMZ 72011C?

Because INAVAMZ 72011C holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

### Is INAVAMZ 72011C leaner than typical WaterSense showerhead models?

Compared with the 1.8 gpm WaterSense showerhead median, INAVAMZ 72011C's 1.75 gpm rating places it below category norms inside EPA conservation limits.

### What annual dollar savings can a 3-person home expect with INAVAMZ 72011C?

Upgrading a 4.0 gpm legacy fixture to INAVAMZ 72011C saves ~19,710 gallons yearly for three occupants, about $217/yr at $11 per 1,000 gallons combined water and sewer.

### What anti-scald valve standard pairs with INAVAMZ 72011C?

Pairing INAVAMZ 72011C (1.75 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

### How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.75 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

### Does installing INAVAMZ 72011C require a municipal plumbing permit?

Like-for-like swaps using INAVAMZ 72011C on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

## What related resources expand on INAVAMZ 72011C?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Compare WaterSense 1.28 gpf vs 3.5 gpf toilets](https://siematic-charleston.com/compare/epa-watersense-128-gpf-vs-35-gpf-legacy-toilet/)
- [Browse all showerheads in registry](https://siematic-charleston.com/watersense-fixtures/showerheads/)
- [Browse 200 U.S. WaterSense utility rebates](https://siematic-charleston.com/rebates/)
- [Innova PF6054-SS WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-innova-pf6054-ss/)
- [Jacuzzi NW50826 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-jacuzzi-nw50826/)
- [Huntington Brass P64313 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-huntington-brass-p64313/)

## Sources

1. [EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets)](https://lookforwatersense.epa.gov/products/) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
2. [EPA WaterSense Utility Rebate Finder API](https://www.epa.gov/watersense/rebate-finder) — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Check U.S. WaterSense Rebates
