title: "LDR 013 8500 WaterSense Showerhead (1.8 gpm) | GradeMark"
url: https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-ldr-013-8500/
description: "EPA WaterSense showerhead LDR 013 8500: 1.8 gpm (28.0% under EPAct 1992), 4,964 gal/person/yr savings and 5 peers. Verified US agency benchmarks."
---

#  LDR 013 8500 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · LDR (1 SKU)

Verified Specification Summary

Certified under EPA WaterSense, LDR 013 8500 tests at 1.8 gpm (#9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads), trimming 28.0% off the 2.5 gpm federal cap while cutting 3-person household draw by ~14,892 gal/yr versus 3.5 gpm fixtures. Compare EPA WaterSense certified flow metrics for LDR 013 8500 WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

- **Certified Flow**: 1.8 gpm

- **vs. EPAct 1992**: -28.0% (2.5 gpm)

- **Annual Draw (1 Pers.)**: 5,256 gal/yr

- **Annual Saved vs. Legacy**: 4,964 gal/person

- **Brand EPA Count**: 4 showerheads

- **Series / Variants**: 013 8500 (1)

WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

## What does LDR 013 8500 Benchmark & Water Budget show?

Efficiency check: certified at 1.8 gpm, LDR 013 8500 trims 28.0% under federal 2.5 gpm caps; #9,841 of 18,544 certified showerheads; below median tier among 18,544 certified showerheads; lower-flow than 19.3% of certified showerheads (0.05 gpm higher-flow than the 1.75 gpm median).

Verify >=30 PSI static water pressure and pair this 1.8 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: LDR holds 4 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~14,892 gallons/yr—roughly $119/yr in low-tariff towns ($8/1k gal), $164/yr at national averages ($11/1k gal), or $268/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 EBD511TO (1.8 gpm) and Better Homes & Gardens BH27097026121TC (1.8 gpm).

## Where does LDR 013 8500 sit on the EPA WaterSense showerhead flow curve?

Comparing LDR 013 8500 (1.80 gpm) against federal EPAct (2.5 gpm) and legacy (3.5 gpm) baselines shows immediate per-use conservation.

## How do subfloor levelness and rough-in height protect LDR 013 8500?

Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.

Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

## What official WaterSense figures verify LDR 013 8500?

Examine LDR 013 8500 certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Registry Share** | LDR (4 certified) | EPA WaterSense Partner |
| **Model Number / Series** | 013 8500 | Certified Series (1 finish variants) |
| **Rated Consumption** | 1.8 gpm | Category median 1.75 gpm (n=18,544 rated) |
| **Shower / Faucet Pairing** | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |

## What annual utility savings does LDR 013 8500 deliver?

Compare 1-to-4-person household water use with LDR 013 8500 against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.

Computed annual water savings for LDR 013 8500 (1.8 gpm)

| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 5,256 gal | 2,044 gal | 4,964 gal (~$55) |
| 2 Occupants | 10,512 gal | 4,088 gal | 9,928 gal (~$109) |
| 3 Occupants | 15,768 gal | 6,132 gal | 14,892 gal (~$119–$268) |
| 4 Occupants | 21,024 gal | 8,176 gal | 19,856 gal (~$218) |

## What alternative WaterSense models compare to LDR 013 8500?

Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.

Peer showerhead models with matching or lower gpm ratings

| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| [**1858 EBD511TO**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-1858-ebd511to/) | 1.8 gpm (Same flow) | Embellish |
| [**Better Homes & Gardens BH27097026121TC**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-better-homes-gardens-bh27097026121tc/) | 1.8 gpm (Same flow) | WaterSense |
| [**DANCO 12158**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-danco-12158/) | 1.8 gpm (Same flow) | WaterSense |
| [**Design House 547430**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-design-house-547430/) | 1.8 gpm (Same flow) | Madison |
| [**For Living 063-6530-2**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-for-living-063-6530-2/) | 1.8 gpm (Same flow) | WaterSense |

## What will LDR 013 8500 save on your annual water bill?

Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.

Household Occupants

Water + Sewer Rate ($ / 1k gal)

## What plumbing or duct constraints rule out LDR 013 8500?

Compare where LDR 013 8500 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Existing shower valve lacks ASSE 1016 pressure balancing

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Meeting 2.5 gpm federal & stricter WaterSense caps
- **Suited to:** Targeting ~$164/yr utility savings (3-person home)

## Which homeowner questions come up most for LDR 013 8500?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around LDR 013 8500.

### Why upgrade a 4.0 gpm fixture to LDR 013 8500 at 1.8 gpm?

Swapping a 4.0 gpm unit for LDR 013 8500 slashes water draw 55.0% (6,424 gal/person/yr), beating 2.5 gpm federal EPAct standards by 28.0%.

### When can LDR 013 8500 (1.8 gpm) underperform in an older bathroom?

Skip LDR 013 8500 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

### How do 133 WaterSense rebate programs treat LDR 013 8500?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like LDR 013 8500, itemized purchase invoices, and residential installation addresses.

### How does LDR 013 8500 perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.8 gpm, LDR 013 8500 sits equal to the category median while clearing federal WaterSense caps.

### How much does a 3-resident family save yearly switching to LDR 013 8500?

At $11 per 1,000 gallons, a 3-person household conserving 19,272 gallons/yr with LDR 013 8500 trims roughly $212 annually off water and sewer utility bills.

### What anti-scald valve standard pairs with LDR 013 8500?

Pairing LDR 013 8500 (1.8 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

### How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.8 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

### Does installing LDR 013 8500 require a municipal plumbing permit?

Like-for-like swaps using LDR 013 8500 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

## Where can you explore more benchmarks around LDR 013 8500?

Use the related reference pages and estimators below to cross-check LDR 013 8500 against state labor wages, WaterSense rebates, and federal grant rules.

- [Compare WaterSense 1.28 gpf vs 3.5 gpf toilets](https://siematic-charleston.com/compare/epa-watersense-128-gpf-vs-35-gpf-legacy-toilet/)
- [Browse all showerheads in registry](https://siematic-charleston.com/watersense-fixtures/showerheads/)
- [Browse 200 U.S. WaterSense utility rebates](https://siematic-charleston.com/rebates/)
- [LEAD ALL A12149 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-lead-all-a12149/)
- [Lixil water Technologies 7417502 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-lixil-water-technologies-7417502/)
- [Landon & Co. F121E412 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-landon-co-f121e412/)

## Sources

1. [EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets)](https://lookforwatersense.epa.gov/products/) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
2. [EPA WaterSense Utility Rebate Finder API](https://www.epa.gov/watersense/rebate-finder) — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Check U.S. WaterSense Rebates

See all 51 states and 200 U.S. utility rebate programs.
[Open Rebate Directory](https://siematic-charleston.com/rebates/)