title: "New Resources Group ES-240-1.75 WaterSense Showerhead (1.75 gpm)"
url: https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-new-resources-group-es-240-1-75/
description: "EPA WaterSense showerhead New Resources Group ES-240-1.75: 1.75 gpm (30.0% under EPAct 1992), 5,110 gal/person/yr savings and 5 peers."
---

#  New Resources Group ES-240-1.75 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · New Resources Group (1 SKU)

Verified Specification Summary

The New Resources Group ES-240-1.75 is an EPA WaterSense showerhead certified at 1.75 gpm, 30.0% below EPAct 1992 (2.5 gpm) and #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads. A 3-person household saves ~15,330 gallons/yr replacing a 3.5 gpm legacy fixture. Compare EPA WaterSense certified flow metrics for New Resources Group ES-240-1.75 WaterSense Showerhead, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

- **Certified Flow**: 1.75 gpm

- **vs. EPAct 1992**: -30.0% (2.5 gpm)

- **Annual Draw (1 Pers.)**: 5,110 gal/yr

- **Annual Saved vs. Legacy**: 5,110 gal/person

- **Brand EPA Count**: 12 showerheads

- **Series / Variants**: ES-240-1.75 (1)

WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

## What does New Resources Group ES-240-1.75 Benchmark & Water Budget show?

Flow standing: New Resources Group ES-240-1.75 operates at 1.75 gpm (balanced WaterSense flow tier), #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads, cutting 30.0% off EPAct 1992 (2.5 gpm).

Verify >=30 PSI static water pressure and pair this 1.75 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: New Resources Group holds 12 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~15,330 gallons/yr—roughly $123/yr in low-tariff towns ($8/1k gal), $169/yr at national averages ($11/1k gal), or $276/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: allen+roth 5283486 (1.75 gpm) and Axor 38442xx1 (1.75 gpm).

## How does New Resources Group ES-240-1.75 compare to EPAct 1992 and legacy gpm rates?

Tested at 1.75 gpm, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (2.5 gpm) and pre-1994 legacy units (3.5 gpm).

## What floor flatness and flange clearances pair with New Resources Group ES-240-1.75?

Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.

Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

## Which EPA WaterSense test specs apply to New Resources Group ES-240-1.75?

Certified EPA WaterSense records for New Resources Group ES-240-1.75 verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Registry Share** | New Resources Group (12 certified) | EPA WaterSense Partner |
| **Model Number / Series** | ES-240-1.75 | Certified Series (1 finish variants) |
| **Rated Consumption** | 1.75 gpm | Category median 1.75 gpm (n=18,544 rated) |
| **Shower / Faucet Pairing** | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |

## How much water and money can New Resources Group ES-240-1.75 save each year?

Household projections below calculate New Resources Group ES-240-1.75 annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.

Computed annual water savings for New Resources Group ES-240-1.75 (1.75 gpm)

| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 5,110 gal | 2,190 gal | 5,110 gal (~$56) |
| 2 Occupants | 10,220 gal | 4,380 gal | 10,220 gal (~$112) |
| 3 Occupants | 15,330 gal | 6,570 gal | 15,330 gal (~$123–$276) |
| 4 Occupants | 20,440 gal | 8,760 gal | 20,440 gal (~$225) |

## Which EPA WaterSense fixtures match New Resources Group ES-240-1.75?

Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.

Peer showerhead models with matching or lower gpm ratings

| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| [**allen+roth 5283486**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-allen-roth-5283486/) | 1.75 gpm (Same flow) | WaterSense |
| [**Axor 38442xx1**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-axor-38442xx1/) | 1.75 gpm (Same flow) | Uno |
| [**COBBE KFSCA12102**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-cobbe-kfsca12102/) | 1.75 gpm (Same flow) | KFSCA12102 |
| [**Current 01932-T**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-current-01932-t/) | 1.75 gpm (Same flow) | WaterSense |
| [**DORNBRACHT 28.647.970-xx0010**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-dornbracht-28-647-970-xx0010/) | 1.75 gpm (Same flow) | WaterSense |

## How much does New Resources Group ES-240-1.75 save at your local water rate?

Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.

Household Occupants

Water + Sewer Rate ($ / 1k gal)

## Where should contractors skip New Resources Group ES-240-1.75 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for New Resources Group ES-240-1.75 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Low static water supply pressure <30 PSI

### Best-Fit Homeowner Profiles

- **Choose this if:** Claiming utility rebates across 200 U.S. WaterSense programs
- **Works well for:** Lowering household draw to 5,110 gal/person/yr

## What key rules and numbers govern New Resources Group ES-240-1.75?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting New Resources Group ES-240-1.75.

### Can homeowners claim utility rebates when installing New Resources Group ES-240-1.75?

Because New Resources Group ES-240-1.75 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

### Is New Resources Group ES-240-1.75 leaner than typical WaterSense showerhead models?

Compared with the 1.8 gpm WaterSense showerhead median, New Resources Group ES-240-1.75's 1.75 gpm rating places it below category norms inside EPA conservation limits.

### What annual dollar savings can a 3-person home expect with New Resources Group ES-240-1.75?

Upgrading a 4.0 gpm legacy fixture to New Resources Group ES-240-1.75 saves ~19,710 gallons yearly for three occupants, about $217/yr at $11 per 1,000 gallons combined water and sewer.

### What anti-scald valve standard pairs with New Resources Group ES-240-1.75?

Pairing New Resources Group ES-240-1.75 (1.75 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

### How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.75 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

### Does installing New Resources Group ES-240-1.75 require a municipal plumbing permit?

Like-for-like swaps using New Resources Group ES-240-1.75 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

### How many gallons per person does New Resources Group ES-240-1.75 save annually?

Each resident saves ~6,570 gallons yearly (56.2% drop) replacing a 4.0 gpm fixture with New Resources Group ES-240-1.75 (1.75 gpm), or 2,190 gal/yr versus 2.5 gpm EPAct baselines.

### Who should NOT install New Resources Group ES-240-1.75 without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.75 gpm showerhead.

## Which guides and calculators connect next to New Resources Group ES-240-1.75?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for New Resources Group ES-240-1.75.

- [Compare WaterSense 1.28 gpf vs 3.5 gpf toilets](https://siematic-charleston.com/compare/epa-watersense-128-gpf-vs-35-gpf-legacy-toilet/)
- [Browse all showerheads in registry](https://siematic-charleston.com/watersense-fixtures/showerheads/)
- [Browse 200 U.S. WaterSense utility rebates](https://siematic-charleston.com/rebates/)
- [Niagara N2915 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-niagara-n2915/)
- [Niagara Conservation N4910 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-niagara-conservation-n4910/)
- [New Resouces ES-606C-1.5 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-new-resouces-es-606c-1-5/)

## Sources

1. [EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets)](https://lookforwatersense.epa.gov/products/) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
2. [EPA WaterSense Utility Rebate Finder API](https://www.epa.gov/watersense/rebate-finder) — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Check U.S. WaterSense Rebates

See all 51 states and 200 U.S. utility rebate programs.
[Open Rebate Directory](https://siematic-charleston.com/rebates/)