---
title: "Perrin and Rowe 5387 WaterSense Showerhead (1.75 gpm)"
url: https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-perrin-rowe-5387/
description: "EPA WaterSense showerhead Perrin and Rowe 5387: 1.75 gpm (30.0% under EPAct 1992), 5,110 gal/person/yr savings and 5 peers. Verified US agency."
---

#  Perrin & Rowe 5387 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Handshower (1 SKU)

Verified Specification Summary

Homeowners upgrading older 3.5 gpm plumbing to Perrin & Rowe 5387 (1.75 gpm, #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads) cut 50.0% off legacy draw, conserving ~15,330 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for Perrin & Rowe 5387 WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

- **Certified Flow**: 1.75 gpm

- **vs. EPAct 1992**: -30.0% (2.5 gpm)

- **Annual Draw (1 Pers.)**: 5,110 gal/yr

- **Annual Saved vs. Legacy**: 5,110 gal/person

- **Brand EPA Count**: 21 showerheads

- **Series / Variants**: 5387 (1)

WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

## What does Perrin & Rowe 5387 Benchmark & Water Budget show?

Laboratory testing places Perrin & Rowe 5387 (Handshower) at 1.75 gpm (balanced WaterSense flow tier), saving 30.0% vs. EPAct 1992 (2.5 gpm) while ranking #3,423 of 18,544 certified showerheads; at the median tier among 18,544 certified showerheads; lower-flow than 46.9% of certified showerheads.

Verify >=30 PSI static water pressure and pair this 1.75 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Perrin & Rowe holds 21 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~15,330 gallons/yr—roughly $123/yr in low-tariff towns ($8/1k gal), $169/yr at national averages ($11/1k gal), or $276/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: allen+roth 5283486 (1.75 gpm) and Axor 38442xx1 (1.75 gpm).

## How do federal gpm limits contrast with Perrin & Rowe 5387 tested flow?

Each bar isolates Perrin & Rowe 5387 (1.75 gpm) relative to the EPA cap, federal EPAct 1992 standard (2.5 gpm), and pre-1994 draw.

## How does wet-zone tile prep interact with Perrin & Rowe 5387 rough-ins?

Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.

Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

## What plumbing standards accompany Perrin & Rowe 5387 installation?

Verify Perrin & Rowe 5387 EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Registry Share** | Perrin & Rowe (21 certified) | EPA WaterSense Partner |
| **Model Number / Series** | 5387 | Handshower (1 finish variants) |
| **Rated Consumption** | 1.75 gpm | Category median 1.75 gpm (n=18,544 rated) |
| **Shower / Faucet Pairing** | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |

## What household water budget fits Perrin & Rowe 5387?

Annual consumption rows below translate Perrin & Rowe 5387 certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.

Computed annual water savings for Perrin & Rowe 5387 (1.75 gpm)

| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 5,110 gal | 2,190 gal | 5,110 gal (~$56) |
| 2 Occupants | 10,220 gal | 4,380 gal | 10,220 gal (~$112) |
| 3 Occupants | 15,330 gal | 6,570 gal | 15,330 gal (~$123–$276) |
| 4 Occupants | 20,440 gal | 8,760 gal | 20,440 gal (~$225) |

## Where can buyers find alternatives to Perrin & Rowe 5387?

Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.

Peer showerhead models with matching or lower gpm ratings

| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| [**allen+roth 5283486**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-allen-roth-5283486/) | 1.75 gpm (Same flow) | WaterSense |
| [**Axor 38442xx1**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-axor-38442xx1/) | 1.75 gpm (Same flow) | Uno |
| [**COBBE KFSCA12102**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-cobbe-kfsca12102/) | 1.75 gpm (Same flow) | KFSCA12102 |
| [**Current 01932-T**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-current-01932-t/) | 1.75 gpm (Same flow) | WaterSense |
| [**DORNBRACHT 28.647.970-xx0010**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-dornbracht-28-647-970-xx0010/) | 1.75 gpm (Same flow) | WaterSense |

## What annual bill drop does Perrin & Rowe 5387 achieve for your family?

Calculate annual gallons conserved and dollar savings for Perrin & Rowe 5387 using your exact occupant count and utility tariff without submitting personal info.

Household Occupants

Water + Sewer Rate ($ / 1k gal)

## When does Perrin & Rowe 5387 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Perrin & Rowe 5387.

### Limitations & Who Should Skip

- Existing shower valve lacks ASSE 1016 pressure balancing

### Best-Fit Homeowner Profiles

- **Recommended when:** Meeting 2.5 gpm federal & stricter WaterSense caps
- **Target scenario:** Targeting ~$169/yr utility savings (3-person home)

## Which code checks and cost facts matter for Perrin & Rowe 5387?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Perrin & Rowe 5387.

### How much does a 3-resident family save yearly switching to Perrin & Rowe 5387?

At $11 per 1,000 gallons, a 3-person household conserving 19,710 gallons/yr with Perrin & Rowe 5387 trims roughly $217 annually off water and sewer utility bills.

### What anti-scald valve standard pairs with Perrin & Rowe 5387?

Pairing Perrin & Rowe 5387 (1.75 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

### How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.75 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

### Does installing Perrin & Rowe 5387 require a municipal plumbing permit?

Like-for-like swaps using Perrin & Rowe 5387 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

### What annual gallon reduction does Perrin & Rowe 5387 achieve over older plumbing?

Testing at 1.75 gpm, Perrin & Rowe 5387 uses 56.2% less water than 4.0 gpm pre-1994 models (30.0% below 2.5 gpm EPAct), conserving 6,570 gallons per resident each year.

### When can Perrin & Rowe 5387 (1.75 gpm) underperform in an older bathroom?

Skip Perrin & Rowe 5387 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

### How do 133 WaterSense rebate programs treat Perrin & Rowe 5387?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Perrin & Rowe 5387, itemized purchase invoices, and residential installation addresses.

### How does Perrin & Rowe 5387 perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.75 gpm, Perrin & Rowe 5387 sits below the category median while clearing federal WaterSense caps.

## How can you cross-check Perrin & Rowe 5387 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Perrin & Rowe 5387.

- [Compare WaterSense 1.28 gpf vs 3.5 gpf toilets](https://siematic-charleston.com/compare/epa-watersense-128-gpf-vs-35-gpf-legacy-toilet/)
- [Browse all showerheads in registry](https://siematic-charleston.com/watersense-fixtures/showerheads/)
- [Browse 200 U.S. WaterSense utility rebates](https://siematic-charleston.com/rebates/)
- [Pfister 015-HV1 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-pfister-015-hv1/)
- [Pioneer Industries SH-402 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-pioneer-industries-sh-402/)
- [Pegasus 577-568 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-pegasus-577-568/)

## Sources

1. [EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets)](https://lookforwatersense.epa.gov/products/) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
2. [EPA WaterSense Utility Rebate Finder API](https://www.epa.gov/watersense/rebate-finder) — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Check U.S. WaterSense Rebates

See all 51 states and 200 U.S. utility rebate programs.
[Open Rebate Directory](https://siematic-charleston.com/rebates/)
