title: "Pfister 973-325 WaterSense Showerhead (1.25 gpm) | GradeMark"
url: https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-pfister-973-325/
description: "EPA WaterSense showerhead Pfister 973-325: 1.25 gpm (50.0% under EPAct 1992), 6,570 gal/person/yr savings and 5 peers. Verified US agency benchmarks."
---

#  Pfister 973-325 WaterSense Showerhead Specifications

EPA WaterSense Certified Showerhead · Showerhead (1 SKU)

Verified Specification Summary

The Pfister 973-325 is an EPA WaterSense showerhead certified at 1.25 gpm, 50.0% below EPAct 1992 (2.5 gpm) and #56 of 18,544 certified showerheads; most water-efficient 3.0% of 18,544 certified showerheads, lower-flow than 97.0% of certified showerheads. A 3-person household saves ~19,710 gallons/yr replacing a 3.5 gpm legacy fixture. Compare EPA WaterSense certified flow metrics for Pfister 973-325 WaterSense Showerhead Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

- **Certified Flow**: 1.25 gpm

- **vs. EPAct 1992**: -50.0% (2.5 gpm)

- **Annual Draw (1 Pers.)**: 3,650 gal/yr

- **Annual Saved vs. Legacy**: 6,570 gal/person

- **Brand EPA Count**: 285 showerheads

- **Series / Variants**: 973-325 (1)

WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

## What does Pfister 973-325 Benchmark & Water Budget show?

Flow standing: Pfister 973-325 (Showerhead) operates at 1.25 gpm (aggressive sub-1.6 gpm conservation tier), #56 of 18,544 certified showerheads; most water-efficient 3.0% of 18,544 certified showerheads, lower-flow than 97.0% of certified showerheads (0.50 gpm lower-flow than the 1.75 gpm median), cutting 50.0% off EPAct 1992 (2.5 gpm).

Verify >=30 PSI static water pressure and pair this 1.25 gpm showerhead with an IPC 412.3 / ASSE 1016 anti-scald pressure-balancing valve; seniors remodeling wet zones often combine low-flow showerheads with 60-inch hand hoses and 250-lb grab bars.

Brand breadth: Pfister holds 285 certified showerheads in EPA files (median 1.75 gpm, range 1.0-2.0). For 3 residents, replacing a 3.5 gpm legacy unit saves ~19,710 gallons/yr—roughly $158/yr in low-tariff towns ($8/1k gal), $217/yr at national averages ($11/1k gal), or $355/yr in high-rate cities ($18/1k gal). Regional utilities such as California Water Service Company (CA) list active rebates among 200 U.S. programs. Closest alternatives: ECO-LOGICAL B125-CH (1.25 gpm) and ECO-LOGICAL B125-W (1.25 gpm).

## How does Pfister 973-325 compare to EPAct 1992 and legacy gpm rates?

Tested at 1.25 gpm, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (2.5 gpm) and pre-1994 legacy units (3.5 gpm).

## What floor flatness and flange clearances pair with Pfister 973-325?

Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.

Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

## Which EPA WaterSense test specs apply to Pfister 973-325?

Certified EPA WaterSense records for Pfister 973-325 verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Registry Share** | Pfister (285 certified) | EPA WaterSense Partner |
| **Model Number / Series** | 973-325 | Showerhead (1 finish variants) |
| **Rated Consumption** | 1.25 gpm | Category median 1.75 gpm (n=18,544 rated) |
| **Shower / Faucet Pairing** | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |

## How much water and money can Pfister 973-325 save each year?

Household projections below calculate Pfister 973-325 annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.

Computed annual water savings for Pfister 973-325 (1.25 gpm)

| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 3,650 gal | 3,650 gal | 6,570 gal (~$72) |
| 2 Occupants | 7,300 gal | 7,300 gal | 13,140 gal (~$145) |
| 3 Occupants | 10,950 gal | 10,950 gal | 19,710 gal (~$158–$355) |
| 4 Occupants | 14,600 gal | 14,600 gal | 26,280 gal (~$289) |

## Which EPA WaterSense fixtures match Pfister 973-325?

Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.

Peer showerhead models with matching or lower gpm ratings

| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| [**ECO-LOGICAL B125-CH**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-eco-logical-b125-ch/) | 1.25 gpm (Same flow) | Showerhead |
| [**ECO-LOGICAL B125-W**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-eco-logical-b125-w/) | 1.25 gpm (Same flow) | Showerhead |
| [**EVOLVE/AM EV3019-BN125-FB**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-evolve-am-ev3019-bn125-fb/) | 1.25 gpm (Same flow) | Showerhead |
| [**EVOLVE/AM EV3019-CP125-FB**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-evolve-am-ev3019-cp125-fb/) | 1.25 gpm (Same flow) | Showerhead |
| [**EVOLVE/AM EV3019-MB125-FB**](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-evolve-am-ev3019-mb125-fb/) | 1.25 gpm (Same flow) | Showerhead |

## How much does Pfister 973-325 save at your local water rate?

Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.

Household Occupants

Water + Sewer Rate ($ / 1k gal)

## When does Pfister 973-325 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Pfister 973-325.

### Limitations & Who Should Skip

- Low static water supply pressure <30 PSI

### Best-Fit Homeowner Profiles

- **Recommended when:** Claiming utility rebates across 200 U.S. WaterSense programs
- **Target scenario:** Lowering household draw to 3,650 gal/person/yr

## What key rules and numbers govern Pfister 973-325?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Pfister 973-325.

### How much does a 3-resident family save yearly switching to Pfister 973-325?

At $11 per 1,000 gallons, a 3-person household conserving 24,090 gallons/yr with Pfister 973-325 trims roughly $265 annually off water and sewer utility bills.

### What anti-scald valve standard pairs with Pfister 973-325?

Pairing Pfister 973-325 (1.25 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

### How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.25 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

### Does installing Pfister 973-325 require a municipal plumbing permit?

Like-for-like swaps using Pfister 973-325 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

### What annual gallon reduction does Pfister 973-325 achieve over older plumbing?

Testing at 1.25 gpm, Pfister 973-325 uses 68.8% less water than 4.0 gpm pre-1994 models (50.0% below 2.5 gpm EPAct), conserving 8,030 gallons per resident each year.

### When can Pfister 973-325 (1.25 gpm) underperform in an older bathroom?

Skip Pfister 973-325 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

### How do 133 WaterSense rebate programs treat Pfister 973-325?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Pfister 973-325, itemized purchase invoices, and residential installation addresses.

### How does Pfister 973-325 perform relative to the EPA WaterSense category median?

Among certified WaterSense showerheads, the national median stands at 1.8 gpm. At 1.25 gpm, Pfister 973-325 sits below the category median while clearing federal WaterSense caps.

## Which guides and calculators connect next to Pfister 973-325?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Pfister 973-325.

- [Compare WaterSense 1.28 gpf vs 3.5 gpf toilets](https://siematic-charleston.com/compare/epa-watersense-128-gpf-vs-35-gpf-legacy-toilet/)
- [Browse all showerheads in registry](https://siematic-charleston.com/watersense-fixtures/showerheads/)
- [Browse 200 U.S. WaterSense utility rebates](https://siematic-charleston.com/rebates/)
- [PF Waterworks PF-0555-C WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-pf-waterworks-pf-0555-c/)
- [Pioneer Industries X-6400078 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-pioneer-industries-x-6400078/)
- [Perrin & Rowe 0226BS1 WaterSense Showerhead Specifications](https://siematic-charleston.com/watersense-fixtures/showerhead/showerhead-perrin-rowe-0226bs1/)

## Sources

1. [EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets)](https://lookforwatersense.epa.gov/products/) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
2. [EPA WaterSense Utility Rebate Finder API](https://www.epa.gov/watersense/rebate-finder) — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Check U.S. WaterSense Rebates

See all 51 states and 200 U.S. utility rebate programs.
[Open Rebate Directory](https://siematic-charleston.com/rebates/)