Skip to main content
Grant Estimator

CPSC Recall #05274: Robertshaw R110 Series Gas Control Valves

Recall Date: 2005-09-16 · Manufacturer: Robertshaw Controls Co., of Long Beach, Calif.
Verified Specification Summary

Federal safety filing #05274 (2005-09-16) alerts homeowners owning Robertshaw R110 Series Gas Control Valves, covering About 178,000, to an active defect: Screws on some water heater valves could break. If this happens, gas could leak from the valve, which poses a risk of gas explosion and fire. Next step: Consumers that believe they may have an affected water heater, please click on http://www.icca.invensys.com/robertshaw/recallarchive.htm. Have the model and serial numbers of your water heater ready. For further assistance, please contact Robertshaw. The model and serial numbers can be found on the manufacturer's label on the water heater. Robertshaw will arrange for a free repair or replacement, if necessary. If you smell gas near the appliance or in the building, immediately leave the area and call your gas company or a certified gas technician to investigate the cause.

Recall Number
05274
Recall Date
2005-09-16
Units Affected
About 178,000
Manufacturer
Robertshaw Controls Co., of Long Beach, Calif.
Bath Recall Corpus
63 active notices
Zero-step curbless shower equipped with fold-down teak bench and brushed steel grab bar
Grab bar, valve, and GFCI electrical compliance checkpoints under CPSC & NEC codes.

What does this benchmark analysis show?

Which wet-zone code clearances protect bathroom occupants from injury?

Inspectors check IPC 412.3 ASSE 1016 anti-scald pressure balancing, dedicated NEC 210.8 / 680.71 GFCI protection, and EPA 40 CFR 745 lead containment above 6 sq ft in pre-1978 housing.

Bathroom Wet-Zone Code Safety: ASSE 1016, NEC 210.8 GFCI and EPA RRP Diagram summarizing three bathroom remodeling compliance zones: IPC 412.3 / ASSE 1016 anti-scald valve, NEC 210.8 / 680.71 dedicated GFCI circuit with service access, and EPA 40 CFR 745 6 sq ft lead-safe trigger in pre-1978 homes. 1. IPC 412.3 / ASSE 1016 Anti-Scald Mixing Valve Balances pressure & temp 1070 limiter on tub fillers 2. NEC 210.8 / 680.71 GFCI Dedicated 15A/20A Circuit Class A ground-fault trip Accessible pump panel 3. EPA 40 CFR 745 > 6 sq ft Pre-1978 Lead-Safe RRP Plastic containment zone EPA-certified firm required
Key residential plumbing, electrical, and lead-containment code checkpoints during bathroom remodeling.

How do public records benchmark Recall #05274 (Robertshaw Controls Co., o)?

Each specification entry below traces Recall #05274 (Robertshaw Controls Co., o) directly to verifiable federal, state, or municipal records without promotional padding.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Official Title CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters CPSC SaferProducts.gov
Identified Hazard Screws on some water heater valves could break. If this happens, gas could leak from the valve, which poses a risk of gas explosion and fire. Reported injury/safety mechanism
Consumer Remedy Consumers that believe they may have an affected water heater, please click on http://www.icca.invensys.com/robertshaw/recallarchive.htm. Have the model and serial numbers of your water heater ready. For further assistance, please contact Robertshaw. The model and serial numbers can be found on the manufacturer's label on the water heater. Robertshaw will arrange for a free repair or replacement, if necessary. If you smell gas near the appliance or in the building, immediately leave the area and call your gas company or a certified gas technician to investigate the cause. Stop use if advised by CPSC
Summary Description The R110 Gas Control Valves being recalled are installed on natural and liquid propane (LP) gas water heaters. The recalled valves were manufactured between July 25, 2005 and August 14, 2005 with production date codes 5-31 through and including 5-33, although not all valves with these date codes are affected. The recalled valves were installed on the following water heater brands: American Proline, Bradford White, GE, GSW, Hotpoint, Jetglas, John Wood, Lochinvar, Premier Plus, Powerflex... https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-

How can homeowners benchmark Recall #05274 (Robertshaw Controls Co., o) totals?

Review the scenario calculations below comparing verified baseline figures for Recall #05274 (Robertshaw Controls Co., o) against standard U.S. residential remodeling and fixture ranges.

Homeowner & contractor verification checkpoints for Recall #05274
Verification StepRequired CheckCode / Safety Rule
1. Model & Date StampMatch Robertshaw R110 Series Gas Control V labelFiling #05274 (2005-09-16)
2. Immediate ActionIsolate unit & check hazard stateScrews on some water heater valves could break. If this ha
3. Manufacturer ClaimRequest free kit or refundConsumers that believe they may have an affected water hea
4. Bathroom Safety AuditCheck ADA 250-lb bar & GFCI rulesDOJ §609 / NEC 210.8

How do peer entries compare against Recall #05274 (Robertshaw Controls Co., o)?

Review adjacent entries listed below to benchmark how Recall #05274 (Robertshaw Controls Co., o) stacks up on direct cost, building code compliance, or technical capacity.

Comparable CPSC notices alongside Recall #05274
Product & Recall #DateHazard
#26026 — VST gas-fired tankless water heaters 2025-10-16 The exhaust duct can crack, allowing gases to escape inside...
#25305 — BASDEHEN Kitchen Faucets, model number... 2025-05-29 The recalled faucets were tested and found to contain lead...
#25306 — KICIMPRO Kitchen Faucets, model number... 2025-05-29 The recalled faucets were tested and found to contain lead...
#25307 — VFAUOSIT Kitchen Faucets, model number 06BNV 2025-05-29 The recalled faucets were tested and found to contain lead...

How do federal and code standards apply to Recall #05274 (Robertshaw Controls Co., o)?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Recall #05274 (Robertshaw Controls Co., o).

What safety precaution applies immediately to CPSC Recall #05274: Robertshaw R110 Series Gas owners?

Because CPSC Recall #05274: Robertshaw R110 Series Gas presents a reported risk (fall or detachment hazard), U.S. CPSC Notice #05274 advises halting active use until Certified Brand completes the approved fix (contact manufacturer for replacement parts or refund).

How do buyers verify current Certified Brand remedy progress on #05274?

Look up U.S. CPSC SaferProducts Notice #05274 (2005-09-16) covering CPSC Recall #05274: Robertshaw R110 Series Gas to inspect direct Certified Brand phone portals, mail-in repair kits, and remedy verification status.

Can contractors resell CPSC Recall #05274: Robertshaw R110 Series Gas subject to Notice #05274?

No. Under federal Consumer Product Safety Act rules governing Recall #05274, selling, transferring, or installing recalled Certified Brand CPSC Recall #05274: Robertshaw R110 Series Gas hardware carrying hazard (fall or detachment hazard) is prohibited.

What mounting rule governs replacing recalled CPSC Recall #05274: Robertshaw R110 Series Gas bath support items?

When replacing recalled bath support hardware similar to CPSC Recall #05274: Robertshaw R110 Series Gas (Notice #05274), anchor brackets into solid 2x8 framing rated for 250 lbs under voluntary 2010 ADA 609.8 and local IRC standards.

Does swapping recalled Certified Brand equipment trigger a permit or EPA RRP?

Removing and replacing defective CPSC Recall #05274: Robertshaw R110 Series Gas under CPSC Recall #05274 rarely triggers permits unless cutting over 6 sq ft of painted pre-1978 wall (EPA 40 CFR 745) or rewiring GFCI lines.

Where can owners file incident reports on CPSC Recall #05274: Robertshaw R110 Series Gas after 2005-09-16?

Submit new malfunction or injury details involving Certified Brand CPSC Recall #05274: Robertshaw R110 Series Gas directly through CPSC SaferProducts.gov referencing Notice #05274 so federal safety investigators log field follow-up incidents.

Do owners need an original receipt for CPSC Recall #05274 (Certified Brand)?

Under CPSC Notice #05274 (2005-09-16), Certified Brand provides the official remedy (contact manufacturer for replacement parts or refund) for CPSC Recall #05274: Robertshaw R110 Series Gas based on model numbers and date stamps rather than store receipts.

Which products fall outside CPSC Notice #05274 for CPSC Recall #05274: Robertshaw R110 Series Gas?

Check your CPSC Recall #05274: Robertshaw R110 Series Gas model plate against Recall #05274: units outside the stated Certified Brand production window are not included in this action.

Sources

  1. CPSC SaferProducts.gov Product Recall REST Web Services — U.S. Consumer Product Safety Commission, 2026 Live API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories