The Air King FR80H (Air King) moves 80 CFM at 0.1 in. w.g. (71.4 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones), and delivers 3.8 CFM/W efficacy, sizing bathrooms up to 71 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King FR80H Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 71.4 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
3.8 CFM/W (#951/1,145)
Static Retention
89.2% @ 0.25"
Motor Draw
21.1 W (7.7 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King FR80H vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 71.4 CFM out of 80 CFM (89.2% retention, 1.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Air King's 62-unit lineup, FR80H (series: Air King) carries PD #4480285 dating to 2025-07-25. Lighting kit: No. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.1 watts, about 7.7 kWh/yr (~$1.23/yr at $0.16/kWh) for 1 hr/day shower timers or 184.8 kWh/yr (~$29.57/yr) continuously. Closest competing matches include HomeWerks Worldwide 7141-80-CTA (80.0 CFM) and HomeWerks Worldwide 7141-80-HW (80.0 CFM).

Where does Air King FR80H sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.0 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

How does duct geometry alter Air King FR80H static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Air King FR80H?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Air King FR80H alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series FR80H / Air King PD ID 4480285 (Qualified 2025-07-25)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (71.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Air King FR80H ventilate safely?

Sizing outputs below convert Air King FR80H tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Air King FR80H
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 71 sq ft1 CFM/sq ft @ 71.4 CFM
Tall Bath (9-ft Ceiling)Up to 63 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 21 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.7 kWh/yr (~$1.23/yr)21.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2184.8 kWh/yr (~$29.57/yr)21.1 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Air King FR80H closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
HomeWerks Worldwide 7141-80-CTA 80 / 59 CFM 1.0 sones (Same) 3.8 CFM/W 4 in. diameter
HomeWerks Worldwide 7141-80-HW 80 / 59 CFM 1.0 sones (Same) 3.8 CFM/W 4 in. diameter
HomeWerks Worldwide 7141-80-RGB 80 / 59 CFM 1.0 sones (Same) 3.8 CFM/W 4 in. diameter
Utilitech 7141-80-L 80 / 59 CFM 1.0 sones (Same) 3.8 CFM/W 4 in. diameter
Broan EZ80 80 / 65.6 CFM 1.0 sones (Same) 3.7 CFM/W 4 in. diameter

Will Air King FR80H clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Air King FR80H satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Which bath layouts should avoid specifying Air King FR80H?

Match Air King FR80H directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 21 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Best for: Bathroom floor <= 71 sq ft with 8-ft ceilings (63 sq ft at 9-ft height)
  • Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Air King FR80H?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Air King FR80H.

What happens to Air King FR80H CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Air King FR80H moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Air King FR80H sit on acoustic comfort for senior homeowners?

Measuring 1.0 sones, Air King FR80H operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Air King FR80H cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Air King FR80H 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Air King FR80H pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King FR80H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King FR80H?

Air King FR80H features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King FR80H's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King FR80H's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Air King FR80H ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Air King FR80H covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Air King FR80H run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Air King FR80H.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories