Skip to main content
Grant Estimator

Amazon Basics B089R8S365 Exhaust Fan Specifications

ENERGY STAR PD #4518687 · Bathroom/Utility Room · Qualified 2025-12-19
Verified Specification Summary

In EPA dataset 8dv7-nngq, Amazon Basics B089R8S365 tests at 110 CFM free discharge (94.3 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 4.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 94 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Amazon Basics B089R8S365 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 94.3 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
4.4 CFM/W (#679/1,145)
Static Retention
85.7% @ 0.25"
Motor Draw
25.0 W (9.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Amazon Basics B089R8S365 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 94.3 CFM out of 110 CFM (85.7% retention, 2.0 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places B089R8S365 (series: BPT18) (PD #4518687) among 1 Amazon Basics entries qualified through 2025-12-19. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include Broan AE110 (110.0 CFM) and Broan AE110 = A000HFKT with AE110F1 (110.0 CFM).

Does Amazon Basics B089R8S365 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Amazon Basics B089R8S365 at 1.0 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Why avoid unvented attic termination with Amazon Basics B089R8S365?

Under ASHRAE 62.2 best practice, Amazon Basics B089R8S365 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Amazon Basics B089R8S365?

Before cutting ceiling drywall or sizing attic transitions for Amazon Basics B089R8S365, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Amazon Basics (1 model) ENERGY STAR Certified Partner
Model Number & Series B089R8S365 / BPT18 PD ID 4518687 (Qualified 2025-12-19)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (94.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Amazon Basics B089R8S365?

Bathroom ventilation sizing below maps Amazon Basics B089R8S365 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Amazon Basics B089R8S365
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 94 sq ft1 CFM/sq ft @ 94.3 CFM
Tall Bath (9-ft Ceiling)Up to 83 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 44 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.1 kWh/yr (~$1.46/yr)25.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2219.0 kWh/yr (~$35.04/yr)25.0 W x 8,760 hrs / 1,000

What peer models sit nearest Amazon Basics B089R8S365 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Amazon Basics B089R8S365.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan AE110 110 / 95.5 CFM 1.0 sones (Same) 4.3 CFM/W 4 in. diameter
Broan AE110 = A000HFKT with AE110F1 110 / 95.5 CFM 1.0 sones (Same) 4.3 CFM/W 4 in. diameter
Broan AE110 = A000HFNF with AE110F1 110 / 95.5 CFM 1.0 sones (Same) 4.3 CFM/W 4 in. diameter
Broan AE110K 110 / 95.5 CFM 1.0 sones (Same) 4.3 CFM/W 4 in. diameter
Broan AE110K = A000HFKT with AE110KF 110 / 95.5 CFM 1.0 sones (Same) 4.3 CFM/W 4 in. diameter

What percentage of room demand does Amazon Basics B089R8S365 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Amazon Basics B089R8S365 tested delivery.

Who should not install Amazon Basics B089R8S365 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Amazon Basics B089R8S365 for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 94.3 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 1.0 sones up to 94 sq ft
  • Primary match: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Amazon Basics B089R8S365?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Amazon Basics B089R8S365.

Why check Amazon Basics B089R8S365 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Amazon Basics B089R8S365 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does Amazon Basics B089R8S365 sound output compare to noisy contractor-grade fans?

Rated at 1.0 sones, Amazon Basics B089R8S365 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Amazon Basics B089R8S365?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Amazon Basics B089R8S365 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Amazon Basics B089R8S365's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Amazon Basics B089R8S365?

Amazon Basics B089R8S365 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Amazon Basics B089R8S365's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Amazon Basics B089R8S365's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Amazon Basics B089R8S365 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Amazon Basics B089R8S365 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Amazon Basics B089R8S365 undersized or poorly matched for a bath renovation?

Skip Amazon Basics B089R8S365 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories