Best HBN536912SS Exhaust Fan Specifications

ENERGY STAR PD #3998913 · Range Hood · Qualified 2025-02-21
Verified Specification Summary

In EPA dataset 8dv7-nngq, Best HBN536912SS tests at 200 CFM free discharge (unpublished 0.25 in. w.g. output) and registers #1 of 607 in quietness (0.0 sones) and delivers 16.6 CFM/W efficacy, meeting residential IRC M1505 sizing up to 200 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Best HBN536912SS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
200 / N/A CFM
Noise @ 0.1"
0.0 sones (#1/607)
Efficacy Rank
16.6 CFM/W (#4/1,145)
Static Retention
0.1" test only
Motor Draw
12.0 W (4.4 kWh/yr)
Duct & Tier
10 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Best HBN536912SS vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.0 sones (#1 of 607 rated models, quietest 1.5% of 607 rated models, quieter than 98.5% of rated models, 1.00 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Free-discharge delivery reaches 200 CFM (#45 of 1,145 certified models) via a 10 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 10 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Best's 17-unit lineup, HBN536912SS (series: RANGE HOOD) carries PD #3998913 dating to 2025-02-21. Lighting kit: Yes. At 16.6 CFM/W (#4 of 1,145, top 1.0% of 1,145 rated models, more efficient than 99.0% of rated models, 11.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.0 watts, about 4.4 kWh/yr (~$0.70/yr at $0.16/kWh) for 1 hr/day shower timers or 105.1 kWh/yr (~$16.82/yr) continuously. Closest competing matches include Best HBN536212SS (200.0 CFM) and Best HBN542912SS (200.0 CFM).

Does Best HBN536912SS fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Best HBN536912SS at 0.0 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.0 sone: 0 sones (1st percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.0 sone: 0 sones (P1)

Why avoid unvented attic termination with Best HBN536912SS?

Under ASHRAE 62.2 best practice, Best HBN536912SS needs insulated 10 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Best HBN536912SS?

Before cutting ceiling drywall or sizing attic transitions for Best HBN536912SS, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Best (17 models) ENERGY STAR Certified Partner
Model Number & Series HBN536912SS / RANGE HOOD PD ID 3998913 (Qualified 2025-02-21)
Duct Connection 10 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (200 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.0 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Best HBN536912SS?

Bathroom ventilation sizing below maps Best HBN536912SS motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Best HBN536912SS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 200 sq ft1 CFM/sq ft @ 200 CFM
Tall Bath (9-ft Ceiling)Up to 177 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 150 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.4 kWh/yr (~$0.70/yr)12.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2105.1 kWh/yr (~$16.82/yr)12.0 W x 8,760 hrs / 1,000

What peer models sit nearest Best HBN536912SS in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Best HBN536912SS.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Best HBN536212SS 200 / N/A CFM 0.0 sones (Same) 16.6 CFM/W 10 in. diameter
Best HBN542912SS 200 / N/A CFM 0.0 sones (Same) 16.6 CFM/W 10 in. diameter
Best HBN548212SS 200 / N/A CFM 0.0 sones (Same) 16.6 CFM/W 10 in. diameter
Best HBN548912SS 200 / N/A CFM 0.0 sones (Same) 16.6 CFM/W 10 in. diameter
Best HBN554212SS 200 / N/A CFM 0.0 sones (Same) 16.6 CFM/W 10 in. diameter

What percentage of room demand does Best HBN536912SS cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Best HBN536912SS tested delivery.

What plumbing or duct constraints rule out Best HBN536912SS?

Compare where Best HBN536912SS excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 200 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around 0.0 sones up to 200 sq ft
  • Suited to: Paired with rigid galvanized 10 in. diameter transition

Where do official rules set limits for Best HBN536912SS?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Best HBN536912SS.

Is Best HBN536912SS quiet enough for a primary bedroom bathroom?

At 0.0 sones, Best HBN536912SS operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Best HBN536912SS energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Best HBN536912SS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Best HBN536912SS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Best HBN536912SS?

Best HBN536912SS features a 10 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Best HBN536912SS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Best HBN536912SS's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Best HBN536912SS serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Best HBN536912SS supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Best HBN536912SS for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Best HBN536912SS lacks adequate reserve.

How does Best HBN536912SS handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Best HBN536912SS yields unlisted 0.25 in. w.g. backpressure figures, so smooth 10 in. diameter rigid metal ducting protects real exhaust.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories