Skip to main content
Grant Estimator

Broan XB50L1 Exhaust Fan Specifications

ENERGY STAR PD #2394316 · Bathroom/Utility Room · Qualified 2022-04-01
Verified Specification Summary

Certified by EPA ENERGY STAR, Broan XB50L1 delivers 50 CFM free-air (50.5 CFM at 0.25 in. w.g.) and registers #24 of 607 in quietness (0.3 sones) and delivers 9.4 CFM/W efficacy, clearing residential IRC M1505 sizing up to 50 sq ft (8-ft height) or 44 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan XB50L1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 50.5 CFM
Noise @ 0.1"
0.3 sones (#24/607)
Efficacy Rank
9.4 CFM/W (#254/1,145)
Static Retention
101.0% @ 0.25"
Motor Draw
5.3 W (1.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan XB50L1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 50.5 CFM out of 50 CFM (101.0% retention, 13.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places XB50L1 (series: ULTRA GREEN) (PD #2394316) among 207 Broan entries qualified through 2022-04-01. Lighting kit: Yes. At 9.4 CFM/W (#254 of 1,145, top 22.4% of 1,145 rated models, more efficient than 77.6% of rated models, 4.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 5.3 watts, about 1.9 kWh/yr (~$0.30/yr at $0.16/kWh) for 1 hr/day shower timers or 46.4 kWh/yr (~$7.42/yr) continuously. Closest competing matches include Broan XB50 (50.0 CFM) and Broan XB50=XB00HwithXB50F (50.0 CFM).

How noisy is Broan XB50L1 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Broan XB50L1 measures 0.3 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.3 sone: 0.3 sones (8th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.3 sone: 0.3 sones (P8)

Why does rigid 4 in. diameter ducting protect Broan XB50L1 airflow?

Connecting Broan XB50L1 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Broan XB50L1 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan XB50L1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series XB50L1 / ULTRA GREEN PD ID 2394316 (Qualified 2022-04-01)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (50.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.3 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit Broan XB50L1?

Calculated coverage metrics translate Broan XB50L1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Broan XB50L1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 50 sq ft1 CFM/sq ft @ 50.5 CFM
Tall Bath (9-ft Ceiling)Up to 44 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)1.9 kWh/yr (~$0.30/yr)5.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.246.4 kWh/yr (~$7.42/yr)5.3 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Broan XB50L1?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan XB50 50 / 50.1 CFM 0.3 sones (Same) 9.8 CFM/W 4 in. diameter
Broan XB50=XB00HwithXB50F 50 / 50.1 CFM 0.3 sones (Same) 9.8 CFM/W 4 in. diameter
Broan XB50 50 / 57.8 CFM 0.3 sones (Same) 11.8 CFM/W 6 in. diameter
Broan XB50=XB00HwithXB50F 50 / 57.8 CFM 0.2 sones (-0.10) 11.8 CFM/W 6 in. diameter
Broan XB50L1 50 / 55.6 CFM 0.2 sones (-0.10) 11.8 CFM/W 6 in. diameter

Does Broan XB50L1 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan XB50L1 percentage capacity without sending data.

Does Broan XB50L1 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan XB50L1 for your remodel.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Moisture load fits 50.5 CFM net static output
  • Best application: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Broan XB50L1?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan XB50L1.

What acoustic sone tier does Broan XB50L1 occupy in EPA filings?

With 0.3 sones at 0.1 in. w.g., Broan XB50L1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

How many kWh per year does Broan XB50L1 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan XB50L1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Broan XB50L1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan XB50L1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan XB50L1?

Broan XB50L1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan XB50L1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan XB50L1's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan XB50L1 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan XB50L1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Broan XB50L1 in a bathroom remodel?

Avoid specifying Broan XB50L1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Broan XB50L1 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan XB50L1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories