Verified by EPA WaterSense at 1.2 gpm, Aidier ID-W3359 sits 45.5% under federal 2.2 gpm ceilings (#1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets) and saves ~6,789 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for Aidier ID-W3359 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.2 gpm
- vs. EPAct 1992
- -45.5% (2.2 gpm)
- Annual Draw (1 Pers.)
- 1,752 gal/yr
- Annual Saved vs. Legacy
- 2,263 gal/person
- Brand EPA Count
- 7 faucets
- Series / Variants
- ID-W3359 (1)

What does Aidier ID-W3359 Benchmark & Water Budget show?
Under EPA WaterSense protocols, Aidier ID-W3359 delivers 1.2 gpm (#1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets), beating the 2.2 gpm federal ceiling by 45.5%.
Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.
Brand breadth: Aidier holds 7 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as California Water Service Company (CA) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Axor 48170xx1 (1.2 gpm).
Where does Aidier ID-W3359 rank among 22,471 certified faucets?
Review how Aidier ID-W3359 (1.20 gpm) places inside EPA WaterSense's 22,471-SKU faucet registry alongside historical 2.75 gpm units.
What plumbing rough-in clearances prevent leaks around Aidier ID-W3359?
Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.
Which certified attributes define Aidier ID-W3359 performance?
Official U.S. EPA WaterSense registry entries below confirm Aidier ID-W3359 rated flow rate, model series status, and household code fit.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | Aidier (7 certified) | EPA WaterSense Partner |
| Model Number / Series | ID-W3359 | Certified Series (1 finish variants) |
| Rated Consumption | 1.2 gpm | Category median 1.2 gpm (n=22,471 rated) |
| Shower / Faucet Pairing | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |
How do Aidier ID-W3359 savings scale from 1 to 4 occupants?
Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to Aidier ID-W3359 across different household sizes.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 1,752 gal | 1,460 gal | 2,263 gal (~$25) |
| 2 Occupants | 3,504 gal | 2,920 gal | 4,526 gal (~$50) |
| 3 Occupants | 5,256 gal | 4,380 gal | 6,789 gal (~$54–$122) |
| 4 Occupants | 7,008 gal | 5,840 gal | 9,052 gal (~$100) |
Which peer fixtures deliver flow close to Aidier ID-W3359?
Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.
| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| 1858 LUM211-PU | 1.2 gpm (Same flow) | Lumoni |
| Axor 48170xx1 | 1.2 gpm (Same flow) | Axoror One |
| B&K 221-015 | 1.2 gpm (Same flow) | Lavatory Faucet |
| B&K 222-311H | 1.2 gpm (Same flow) | Lavatory Faucet |
| BALDOR BAC-V11MG | 1.2 gpm (Same flow) | WaterSense |
Does Aidier ID-W3359 pay off faster in high-rate cities?
Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark Aidier ID-W3359 annual savings immediately.
What plumbing or duct constraints rule out Aidier ID-W3359?
Compare where Aidier ID-W3359 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Multi-outlet body spray manifold exceeding single-head flow
Best-Fit Homeowner Profiles
- Homeowner profile: Upgrading 2.75 gpm fixtures for 56.4% water reduction
- Suited to: Matching Aidier SKU ID-W3359 certification on rebate forms
Where do official rules set limits for Aidier ID-W3359?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Aidier ID-W3359.
How much does a 3-resident family save yearly switching to Aidier ID-W3359?
At $11 per 1,000 gallons, a 3-person household conserving 24,528 gallons/yr with Aidier ID-W3359 trims roughly $270 annually off water and sewer utility bills.
What anti-scald valve standard pairs with Aidier ID-W3359?
Pairing Aidier ID-W3359 (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.
How is EPA WaterSense performance tested beyond raw gpm flow caps?
EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.
Does installing Aidier ID-W3359 require a municipal plumbing permit?
Like-for-like swaps using Aidier ID-W3359 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
Why upgrade a 4.0 gpm fixture to Aidier ID-W3359 at 1.2 gpm?
Swapping a 4.0 gpm unit for Aidier ID-W3359 slashes water draw 70.0% (8,176 gal/person/yr), beating 2.2 gpm federal EPAct standards by 45.5%.
When can Aidier ID-W3359 (1.2 gpm) underperform in an older bathroom?
Skip Aidier ID-W3359 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.
How do 133 WaterSense rebate programs treat Aidier ID-W3359?
Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Aidier ID-W3359, itemized purchase invoices, and residential installation addresses.
How does Aidier ID-W3359 perform relative to the EPA WaterSense category median?
Among certified WaterSense faucets, the national median stands at 1.2 gpm. At 1.2 gpm, Aidier ID-W3359 sits equal to the category median while clearing federal WaterSense caps.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)