Verified by EPA WaterSense at 1.2 gpm, Aqua Vista H08L-412-AV sits 45.5% under federal 2.2 gpm ceilings (#1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets) and saves ~6,789 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for Aqua Vista H08L-412-AV WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.2 gpm
- vs. EPAct 1992
- -45.5% (2.2 gpm)
- Annual Draw (1 Pers.)
- 1,752 gal/yr
- Annual Saved vs. Legacy
- 2,263 gal/person
- Brand EPA Count
- 8 faucets
- Series / Variants
- H08L-412-AV (1)

What does Aqua Vista H08L-412-AV Benchmark & Water Budget show?
Under EPA WaterSense protocols, Aqua Vista H08L-412-AV delivers 1.2 gpm (#1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets), beating the 2.2 gpm federal ceiling by 45.5%.
Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.
Brand breadth: Aqua Vista holds 8 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Tucson - Tucson Water (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).
Where does Aqua Vista H08L-412-AV rank among 22,471 certified faucets?
Review how Aqua Vista H08L-412-AV (1.20 gpm) places inside EPA WaterSense's 22,471-SKU faucet registry alongside historical 2.75 gpm units.
What plumbing rough-in clearances prevent leaks around Aqua Vista H08L-412-AV?
Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.
Which certified attributes define Aqua Vista H08L-412-AV performance?
Official U.S. EPA WaterSense registry entries below confirm Aqua Vista H08L-412-AV rated flow rate, model series status, and household code fit.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | Aqua Vista (8 certified) | EPA WaterSense Partner |
| Model Number / Series | H08L-412-AV | Certified Series (1 finish variants) |
| Rated Consumption | 1.2 gpm | Category median 1.2 gpm (n=22,471 rated) |
| Shower / Faucet Pairing | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |
How do Aqua Vista H08L-412-AV savings scale from 1 to 4 occupants?
Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to Aqua Vista H08L-412-AV across different household sizes.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 1,752 gal | 1,460 gal | 2,263 gal (~$25) |
| 2 Occupants | 3,504 gal | 2,920 gal | 4,526 gal (~$50) |
| 3 Occupants | 5,256 gal | 4,380 gal | 6,789 gal (~$54–$122) |
| 4 Occupants | 7,008 gal | 5,840 gal | 9,052 gal (~$100) |
Which peer fixtures deliver flow close to Aqua Vista H08L-412-AV?
Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.
| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| 1858 LUM211-PU | 1.2 gpm (Same flow) | Lumoni |
| Aidier ID-B3594 | 1.2 gpm (Same flow) | WaterSense |
| Axor 48170xx1 | 1.2 gpm (Same flow) | Axoror One |
| B&K 221-015 | 1.2 gpm (Same flow) | Lavatory Faucet |
| B&K 222-311H | 1.2 gpm (Same flow) | Lavatory Faucet |
Does Aqua Vista H08L-412-AV pay off faster in high-rate cities?
Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark Aqua Vista H08L-412-AV annual savings immediately.
Does Aqua Vista H08L-412-AV suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Aqua Vista H08L-412-AV for your remodel.
Limitations & Who Should Skip
- Multi-outlet body spray manifold exceeding single-head flow
Best-Fit Homeowner Profiles
- Strong scenario: Upgrading 2.75 gpm fixtures for 56.4% water reduction
- Best application: Matching Aqua Vista SKU H08L-412-AV certification on rebate forms
Where do official rules set limits for Aqua Vista H08L-412-AV?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Aqua Vista H08L-412-AV.
Does Aqua Vista H08L-412-AV cut utility costs noticeably for a 3-person household?
Yes: cutting 24,528 gallons/yr relative to 4.0 gpm hardware translates to ~$270/yr in combined water/sewer savings at $11/1k gal.
What anti-scald valve standard pairs with Aqua Vista H08L-412-AV?
Pairing Aqua Vista H08L-412-AV (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.
How is EPA WaterSense performance tested beyond raw gpm flow caps?
EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.
Does installing Aqua Vista H08L-412-AV require a municipal plumbing permit?
Like-for-like swaps using Aqua Vista H08L-412-AV on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
What efficiency edge separates Aqua Vista H08L-412-AV from legacy and EPAct models?
Certified at 1.2 gpm, Aqua Vista H08L-412-AV achieves 45.5% savings against EPAct 1992 (2.2 gpm) and 70.0% savings against 4.0 gpm fixtures, 8,176 gallons per occupant yearly.
What supply pressure checks protect Aqua Vista H08L-412-AV spray performance?
Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.2 gpm trim.
Does Aqua Vista H08L-412-AV qualify for municipal utility water rebates in 2026?
Yes, EPA WaterSense certification makes Aqua Vista H08L-412-AV eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.
Where does Aqua Vista H08L-412-AV rank against other certified faucets?
Rated at 1.2 gpm, Aqua Vista H08L-412-AV measures equal to the 1.2 gpm WaterSense faucet median across thousands of EPA-listed residential fixtures.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)