Skip to main content
Grant Estimator

CHESTON 110315-P-D WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · CHESTON (1 SKU)
Verified Specification Summary

Verified by EPA WaterSense at 1.2 gpm, CHESTON 110315-P-D sits 45.5% under federal 2.2 gpm ceilings (#1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets) and saves ~6,789 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for CHESTON 110315-P-D WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.2 gpm
vs. EPAct 1992
-45.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,752 gal/yr
Annual Saved vs. Legacy
2,263 gal/person
Brand EPA Count
20 faucets
Series / Variants
110315-P-D (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does CHESTON 110315-P-D Benchmark & Water Budget show?

Under EPA WaterSense protocols, CHESTON 110315-P-D delivers 1.2 gpm (#1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets), beating the 2.2 gpm federal ceiling by 45.5%.

Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: CHESTON holds 20 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).

Where does CHESTON 110315-P-D rank among 22,471 certified faucets?

Review how CHESTON 110315-P-D (1.20 gpm) places inside EPA WaterSense's 22,471-SKU faucet registry alongside historical 2.75 gpm units.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 110315-P-D: 1.20; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)110315-P-D: 1.20110315-P-D1.20EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.2 gpm: 1.2 gpm (67th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.2 gpm: 1.2 gpm (P67)

What plumbing rough-in clearances prevent leaks around CHESTON 110315-P-D?

Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which certified attributes define CHESTON 110315-P-D performance?

Official U.S. EPA WaterSense registry entries below confirm CHESTON 110315-P-D rated flow rate, model series status, and household code fit.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share CHESTON (20 certified) EPA WaterSense Partner
Model Number / Series 110315-P-D Certified Series (1 finish variants)
Rated Consumption 1.2 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How do CHESTON 110315-P-D savings scale from 1 to 4 occupants?

Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to CHESTON 110315-P-D across different household sizes.

Computed annual water savings for CHESTON 110315-P-D (1.2 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,752 gal1,460 gal2,263 gal (~$25)
2 Occupants3,504 gal2,920 gal4,526 gal (~$50)
3 Occupants5,256 gal4,380 gal6,789 gal (~$54–$122)
4 Occupants7,008 gal5,840 gal9,052 gal (~$100)

Which peer fixtures deliver flow close to CHESTON 110315-P-D?

Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 LUM211-PU 1.2 gpm (Same flow) Lumoni
Aidier ID-B3594 1.2 gpm (Same flow) WaterSense
Axor 48170xx1 1.2 gpm (Same flow) Axoror One
B&K 221-015 1.2 gpm (Same flow) Lavatory Faucet
B&K 222-311H 1.2 gpm (Same flow) Lavatory Faucet

Does CHESTON 110315-P-D pay off faster in high-rate cities?

Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark CHESTON 110315-P-D annual savings immediately.

Where should contractors skip CHESTON 110315-P-D on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for CHESTON 110315-P-D carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Choose this if: Upgrading 2.75 gpm fixtures for 56.4% water reduction
  • Works well for: Matching CHESTON SKU 110315-P-D certification on rebate forms

Where do official rules set limits for CHESTON 110315-P-D?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing CHESTON 110315-P-D.

How many gallons per person does CHESTON 110315-P-D save annually?

Each resident saves ~8,176 gallons yearly (70.0% drop) replacing a 4.0 gpm fixture with CHESTON 110315-P-D (1.2 gpm), or 2,920 gal/yr versus 2.2 gpm EPAct baselines.

Who should NOT install CHESTON 110315-P-D without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.2 gpm faucet.

Can homeowners claim utility rebates when installing CHESTON 110315-P-D?

Because CHESTON 110315-P-D holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is CHESTON 110315-P-D leaner than typical WaterSense faucet models?

Compared with the 1.2 gpm WaterSense faucet median, CHESTON 110315-P-D's 1.2 gpm rating places it equal to category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with CHESTON 110315-P-D?

Upgrading a 4.0 gpm legacy fixture to CHESTON 110315-P-D saves ~24,528 gallons yearly for three occupants, about $270/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with CHESTON 110315-P-D?

Pairing CHESTON 110315-P-D (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing CHESTON 110315-P-D require a municipal plumbing permit?

Like-for-like swaps using CHESTON 110315-P-D on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories