Skip to main content
Grant Estimator

CMI® 192-8224 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Single Handle Lavatory Faucet (9 SKUs)
Verified Specification Summary

Listed in EPA WaterSense files at 1.2 gpm, CMI® 192-8224 achieves #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets and lowers household water use ~6,789 gal/yr (3 residents) against pre-1994 2.75 gpm fixtures. Compare EPA WaterSense certified flow metrics for CMI® 192-8224 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.2 gpm
vs. EPAct 1992
-45.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,752 gal/yr
Annual Saved vs. Legacy
2,263 gal/person
Brand EPA Count
61 faucets
Series / Variants
192-8224 (9)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does CMI® 192-8224 Benchmark & Water Budget show?

Certified discharge for CMI® 192-8224 (Single Handle Lavatory Faucet) measures 1.2 gpm (aggressive sub-1.6 gpm conservation tier), standing #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets against the 2.2 gpm standard.

Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: CMI® holds 61 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).

Does CMI® 192-8224 beat the 1.2 gpm WaterSense faucet median?

Certified at 1.20 gpm, CMI® 192-8224 sits well under EPAct 1992 limits (2.2 gpm) across 22,471 EPA-registered faucets.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 192-8224: 1.20; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)192-8224: 1.20192-82241.20EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.2 gpm: 1.2 gpm (67th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.2 gpm: 1.2 gpm (P67)

Why check closet flange height and L/360 stiffness around CMI® 192-8224?

Checking framing deflection (L/360) and finished tile-to-flange elevation before fixture mounting eliminates wobble and concealed floor leaks.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Where does CMI® 192-8224 fit in EPA WaterSense files?

Review certified water flow, brand lineup breadth, and ASSE 1016 valve or IPC closet flange pairing guidelines for CMI® 192-8224.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share CMI® (61 certified) EPA WaterSense Partner
Model Number / Series 192-8224 Single Handle Lavatory Faucet (9 finish variants)
Rated Consumption 1.2 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 9 finish and trim SKUs share the CMI® 192-8224 WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 8 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into CMI® 192-8224 (9 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
192-82241.2 gpmSingle Handle Lavatory Faucet
192-82251.2 gpmSingle Handle Lavatory Faucet
192-82201.2 gpmSingle Handle Lavatory Faucet
192-82221.2 gpmSingle Handle Lavatory Faucet
192-83211.2 gpmSingle Handle Lavatory Faucet
192-82211.2 gpmSingle Handle Lavatory Faucet
192-82261.2 gpmSingle Handle Lavatory Faucet
192-83201.2 gpmSingle Handle Lavatory Faucet

Does CMI® 192-8224 lower water bills for larger households?

Review computed annual water totals for 1 to 4 residents comparing CMI® 192-8224 certified consumption with older pre-1994 residential plumbing hardware.

Computed annual water savings for CMI® 192-8224 (1.2 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,752 gal1,460 gal2,263 gal (~$25)
2 Occupants3,504 gal2,920 gal4,526 gal (~$50)
3 Occupants5,256 gal4,380 gal6,789 gal (~$54–$122)
4 Occupants7,008 gal5,840 gal9,052 gal (~$100)

How do similar WaterSense brands compare with CMI® 192-8224?

Comparable certified models listed below share CMI® 192-8224 category standards while offering alternative brand warranties and rough-in configurations.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 LUM211-PU 1.2 gpm (Same flow) Lumoni
Aidier ID-B3594 1.2 gpm (Same flow) WaterSense
Axor 48170xx1 1.2 gpm (Same flow) Axoror One
B&K 221-015 1.2 gpm (Same flow) Lavatory Faucet
B&K 222-311H 1.2 gpm (Same flow) Lavatory Faucet

How do local water rates change CMI® 192-8224 savings?

Use the local browser estimator below with your city water-sewer rate and household size to quantify CMI® 192-8224 yearly utility impact.

Which bath layouts should avoid specifying CMI® 192-8224?

Match CMI® 192-8224 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Low static water supply pressure <30 PSI

Best-Fit Homeowner Profiles

  • Best for: Claiming utility rebates across 200 U.S. WaterSense programs
  • Optimal use: Lowering household draw to 1,752 gal/person/yr

What should homeowners verify first about CMI® 192-8224?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to CMI® 192-8224.

Does CMI® 192-8224 cut utility costs noticeably for a 3-person household?

Yes: cutting 24,528 gallons/yr relative to 4.0 gpm hardware translates to ~$270/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with CMI® 192-8224?

Pairing CMI® 192-8224 (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing CMI® 192-8224 require a municipal plumbing permit?

Like-for-like swaps using CMI® 192-8224 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How does CMI® 192-8224 cut household water draw versus 1992 federal rules?

Delivering 1.2 gpm, CMI® 192-8224 trims 2,920 gal/person/yr below 2.2 gpm EPAct caps (45.5% reduction) and 8,176 gal/person/yr under 4.0 gpm legacy fixtures.

What supply pressure checks protect CMI® 192-8224 spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.2 gpm trim.

Does CMI® 192-8224 qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes CMI® 192-8224 eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does CMI® 192-8224 rank against other certified faucets?

Rated at 1.2 gpm, CMI® 192-8224 measures equal to the 1.2 gpm WaterSense faucet median across thousands of EPA-listed residential fixtures.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories