Skip to main content
Grant Estimator

Conservation Management Solutions 50477XX WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Conservation Management Solutions (1 SKU)
Verified Specification Summary

Listed in EPA WaterSense files at 1.5 gpm, Conservation Management Solutions 50477XX achieves #15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm and lowers household water use ~5,475 gal/yr (3 residents) against pre-1994 2.75 gpm fixtures. Compare EPA WaterSense certified flow metrics for Conservation Management Solutions 50477XX WaterSense, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.5 gpm
vs. EPAct 1992
-31.8% (2.2 gpm)
Annual Draw (1 Pers.)
2,190 gal/yr
Annual Saved vs. Legacy
1,825 gal/person
Brand EPA Count
17 faucets
Series / Variants
50477XX (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Conservation Management Solutions 50477XX Benchmark & Water Budget show?

Certified discharge for Conservation Management Solutions 50477XX measures 1.5 gpm (aggressive sub-1.6 gpm conservation tier), standing #15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm (0.30 gpm higher-flow than the 1.20 gpm median) against the 2.2 gpm standard.

Pair this 1.5 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Conservation Management Solutions holds 17 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~5,475 gallons/yr—roughly $44/yr in low-tariff towns ($8/1k gal), $60/yr at national averages ($11/1k gal), or $99/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: AM Conservation Group, Inc. FA012CPB1WS (1.5 gpm) and Amazon 90457.05 (1.5 gpm).

Does Conservation Management Solutions 50477XX beat the 1.2 gpm WaterSense faucet median?

Certified at 1.50 gpm, Conservation Management Solutions 50477XX sits well under EPAct 1992 limits (2.2 gpm) across 22,471 EPA-registered faucets.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 50477XX: 1.50; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)50477XX: 1.5050477XX1.50EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.5 gpm: 1.5 gpm (100th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.5 gpm: 1.5 gpm (P100)

Why check closet flange height and L/360 stiffness around Conservation Management Solutions 50477XX?

Checking framing deflection (L/360) and finished tile-to-flange elevation before fixture mounting eliminates wobble and concealed floor leaks.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Where does Conservation Management Solutions 50477XX fit in EPA WaterSense files?

Review certified water flow, brand lineup breadth, and ASSE 1016 valve or IPC closet flange pairing guidelines for Conservation Management Solutions 50477XX.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Conservation Management Solutions (17 certified) EPA WaterSense Partner
Model Number / Series 50477XX Certified Series (1 finish variants)
Rated Consumption 1.5 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Does Conservation Management Solutions 50477XX lower water bills for larger households?

Review computed annual water totals for 1 to 4 residents comparing Conservation Management Solutions 50477XX certified consumption with older pre-1994 residential plumbing hardware.

Computed annual water savings for Conservation Management Solutions 50477XX (1.5 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,190 gal1,022 gal1,825 gal (~$20)
2 Occupants4,380 gal2,044 gal3,650 gal (~$40)
3 Occupants6,570 gal3,066 gal5,475 gal (~$44–$99)
4 Occupants8,760 gal4,088 gal7,300 gal (~$80)

How do similar WaterSense brands compare with Conservation Management Solutions 50477XX?

Comparable certified models listed below share Conservation Management Solutions 50477XX category standards while offering alternative brand warranties and rough-in configurations.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
AM Conservation Group, Inc. FA012CPB1WS 1.5 gpm (Same flow) WaterSense
Amazon 90457.05 1.5 gpm (Same flow) WaterSense
Aqueous™, Estora™ or Homewerks Worldwide 20-B41CY-Z 1.5 gpm (Same flow) WaterSense
Aqueous™, Estora™ or Homewerks Worldwide 30-B41WN-Z 1.5 gpm (Same flow) WaterSense
Brookfield 192-8268 1.5 gpm (Same flow) CMI 3252C Chrome Two Handle Deluxe...

How do local water rates change Conservation Management Solutions 50477XX savings?

Use the local browser estimator below with your city water-sewer rate and household size to quantify Conservation Management Solutions 50477XX yearly utility impact.

What plumbing or duct constraints rule out Conservation Management Solutions 50477XX?

Compare where Conservation Management Solutions 50477XX excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Low static water supply pressure <30 PSI

Best-Fit Homeowner Profiles

  • Homeowner profile: Claiming utility rebates across 200 U.S. WaterSense programs
  • Suited to: Lowering household draw to 2,190 gal/person/yr

What should homeowners verify first about Conservation Management Solutions 50477XX?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Conservation Management Solutions 50477XX.

How does Conservation Management Solutions 50477XX perform relative to the EPA WaterSense category median?

Among certified WaterSense faucets, the national median stands at 1.2 gpm. At 1.5 gpm, Conservation Management Solutions 50477XX sits slightly above the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Conservation Management Solutions 50477XX?

At $11 per 1,000 gallons, a 3-person household conserving 21,900 gallons/yr with Conservation Management Solutions 50477XX trims roughly $241 annually off water and sewer utility bills.

What anti-scald valve standard pairs with Conservation Management Solutions 50477XX?

Pairing Conservation Management Solutions 50477XX (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Conservation Management Solutions 50477XX require a municipal plumbing permit?

Like-for-like swaps using Conservation Management Solutions 50477XX on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 4.0 gpm fixture to Conservation Management Solutions 50477XX at 1.5 gpm?

Swapping a 4.0 gpm unit for Conservation Management Solutions 50477XX slashes water draw 62.5% (7,300 gal/person/yr), beating 2.2 gpm federal EPAct standards by 31.8%.

When can Conservation Management Solutions 50477XX (1.5 gpm) underperform in an older bathroom?

Skip Conservation Management Solutions 50477XX without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat Conservation Management Solutions 50477XX?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Conservation Management Solutions 50477XX, itemized purchase invoices, and residential installation addresses.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories