Skip to main content
Grant Estimator

Conservation Management Systems 50664xx WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Conservation Management Systems (1 SKU)
Verified Specification Summary

Listed in EPA WaterSense files at 1.0 gpm, Conservation Management Systems 50664xx achieves #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets and lowers household water use ~7,665 gal/yr (3 residents) against pre-1994 2.75 gpm fixtures. Compare EPA WaterSense certified flow metrics for Conservation Management Systems 50664xx WaterSense, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.0 gpm
vs. EPAct 1992
-54.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
2,555 gal/person
Brand EPA Count
1 faucet
Series / Variants
50664xx (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Conservation Management Systems 50664xx Benchmark & Water Budget show?

Certified discharge for Conservation Management Systems 50664xx measures 1.0 gpm (aggressive sub-1.6 gpm conservation tier), standing #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets (0.20 gpm lower-flow than the 1.20 gpm median) against the 2.2 gpm standard.

Pair this 1.0 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Conservation Management Systems holds 1 certified faucet in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~7,665 gallons/yr—roughly $61/yr in low-tariff towns ($8/1k gal), $84/yr at national averages ($11/1k gal), or $138/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: allen + roth QFS6A0229 (1.0 gpm) and Belanger IND79C (1.0 gpm).

Does Conservation Management Systems 50664xx beat the 1.2 gpm WaterSense faucet median?

Certified at 1.00 gpm, Conservation Management Systems 50664xx sits well under EPAct 1992 limits (2.2 gpm) across 22,471 EPA-registered faucets.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 50664xx: 1.00; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)50664xx: 1.0050664xx1.00EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.0 gpm: 1 gpm (8th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.0 gpm: 1 gpm (P8)

Why check closet flange height and L/360 stiffness around Conservation Management Systems 50664xx?

Checking framing deflection (L/360) and finished tile-to-flange elevation before fixture mounting eliminates wobble and concealed floor leaks.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Where does Conservation Management Systems 50664xx fit in EPA WaterSense files?

Review certified water flow, brand lineup breadth, and ASSE 1016 valve or IPC closet flange pairing guidelines for Conservation Management Systems 50664xx.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Conservation Management Systems (1 certified) EPA WaterSense Partner
Model Number / Series 50664xx Certified Series (1 finish variants)
Rated Consumption 1.0 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Does Conservation Management Systems 50664xx lower water bills for larger households?

Review computed annual water totals for 1 to 4 residents comparing Conservation Management Systems 50664xx certified consumption with older pre-1994 residential plumbing hardware.

Computed annual water savings for Conservation Management Systems 50664xx (1.0 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,752 gal2,555 gal (~$28)
2 Occupants2,920 gal3,504 gal5,110 gal (~$56)
3 Occupants4,380 gal5,256 gal7,665 gal (~$61–$138)
4 Occupants5,840 gal7,008 gal10,220 gal (~$112)

How do similar WaterSense brands compare with Conservation Management Systems 50664xx?

Comparable certified models listed below share Conservation Management Systems 50664xx category standards while offering alternative brand warranties and rough-in configurations.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen + roth QFS6A0229 1.0 gpm (Same flow) VEDA
Belanger IND79C 1.0 gpm (Same flow) WaterSense
Chicago Faucet E80-A11E-16ABCP 1.0 gpm (Same flow) WaterSense
Delta 24T2a7b 1.0 gpm (Same flow) WaterSense
Delta 27T5a7b 1.0 gpm (Same flow) WaterSense

How do local water rates change Conservation Management Systems 50664xx savings?

Use the local browser estimator below with your city water-sewer rate and household size to quantify Conservation Management Systems 50664xx yearly utility impact.

When does Conservation Management Systems 50664xx fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Conservation Management Systems 50664xx.

Limitations & Who Should Skip

  • Low static water supply pressure <30 PSI

Best-Fit Homeowner Profiles

  • Recommended when: Claiming utility rebates across 200 U.S. WaterSense programs
  • Target scenario: Lowering household draw to 1,460 gal/person/yr

What should homeowners verify first about Conservation Management Systems 50664xx?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Conservation Management Systems 50664xx.

When can Conservation Management Systems 50664xx (1.0 gpm) underperform in an older bathroom?

Skip Conservation Management Systems 50664xx without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat Conservation Management Systems 50664xx?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Conservation Management Systems 50664xx, itemized purchase invoices, and residential installation addresses.

How does Conservation Management Systems 50664xx perform relative to the EPA WaterSense category median?

Among certified WaterSense faucets, the national median stands at 1.2 gpm. At 1.0 gpm, Conservation Management Systems 50664xx sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Conservation Management Systems 50664xx?

At $11 per 1,000 gallons, a 3-person household conserving 26,280 gallons/yr with Conservation Management Systems 50664xx trims roughly $289 annually off water and sewer utility bills.

What anti-scald valve standard pairs with Conservation Management Systems 50664xx?

Pairing Conservation Management Systems 50664xx (1.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Conservation Management Systems 50664xx require a municipal plumbing permit?

Like-for-like swaps using Conservation Management Systems 50664xx on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What annual gallon reduction does Conservation Management Systems 50664xx achieve over older plumbing?

Testing at 1.0 gpm, Conservation Management Systems 50664xx uses 75.0% less water than 4.0 gpm pre-1994 models (54.5% below 2.2 gpm EPAct), conserving 8,760 gallons per resident each year.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories