Skip to main content
Grant Estimator

Crosswater Ltd US-WF131WNX WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Crosswater Ltd (1 SKU)
Verified Specification Summary

The Crosswater Ltd US-WF131WNX is an EPA WaterSense faucet certified at 1.2 gpm, 45.5% below EPAct 1992 (2.2 gpm) and #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets. A 3-person household saves ~6,789 gallons/yr replacing a 2.75 gpm legacy fixture. Compare EPA WaterSense certified flow metrics for Crosswater Ltd US-WF131WNX WaterSense Faucet, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.2 gpm
vs. EPAct 1992
-45.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,752 gal/yr
Annual Saved vs. Legacy
2,263 gal/person
Brand EPA Count
15 faucets
Series / Variants
US-WF131WNX (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Crosswater Ltd US-WF131WNX Benchmark & Water Budget show?

Flow standing: Crosswater Ltd US-WF131WNX operates at 1.2 gpm (aggressive sub-1.6 gpm conservation tier), #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets, cutting 45.5% off EPAct 1992 (2.2 gpm).

Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Crosswater Ltd holds 15 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).

How does Crosswater Ltd US-WF131WNX compare to EPAct 1992 and legacy gpm rates?

Tested at 1.20 gpm, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (2.2 gpm) and pre-1994 legacy units (2.75 gpm).

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): US-WF131WNX: 1.20; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)US-WF131WNX: 1.20US-WF131WNX1.20EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.2 gpm: 1.2 gpm (67th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.2 gpm: 1.2 gpm (P67)

What floor flatness and flange clearances pair with Crosswater Ltd US-WF131WNX?

Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which EPA WaterSense test specs apply to Crosswater Ltd US-WF131WNX?

Certified EPA WaterSense records for Crosswater Ltd US-WF131WNX verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Crosswater Ltd (15 certified) EPA WaterSense Partner
Model Number / Series US-WF131WNX Certified Series (1 finish variants)
Rated Consumption 1.2 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How much water and money can Crosswater Ltd US-WF131WNX save each year?

Household projections below calculate Crosswater Ltd US-WF131WNX annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.

Computed annual water savings for Crosswater Ltd US-WF131WNX (1.2 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,752 gal1,460 gal2,263 gal (~$25)
2 Occupants3,504 gal2,920 gal4,526 gal (~$50)
3 Occupants5,256 gal4,380 gal6,789 gal (~$54–$122)
4 Occupants7,008 gal5,840 gal9,052 gal (~$100)

Which EPA WaterSense fixtures match Crosswater Ltd US-WF131WNX?

Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 LUM211-PU 1.2 gpm (Same flow) Lumoni
Aidier ID-B3594 1.2 gpm (Same flow) WaterSense
Axor 48170xx1 1.2 gpm (Same flow) Axoror One
B&K 221-015 1.2 gpm (Same flow) Lavatory Faucet
B&K 222-311H 1.2 gpm (Same flow) Lavatory Faucet

How much does Crosswater Ltd US-WF131WNX save at your local water rate?

Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.

Does Crosswater Ltd US-WF131WNX suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Crosswater Ltd US-WF131WNX for your remodel.

Limitations & Who Should Skip

  • Low static water supply pressure <30 PSI

Best-Fit Homeowner Profiles

  • Strong scenario: Claiming utility rebates across 200 U.S. WaterSense programs
  • Best application: Lowering household draw to 1,752 gal/person/yr

What key rules and numbers govern Crosswater Ltd US-WF131WNX?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Crosswater Ltd US-WF131WNX.

Where does Crosswater Ltd US-WF131WNX rank against other certified faucets?

Rated at 1.2 gpm, Crosswater Ltd US-WF131WNX measures equal to the 1.2 gpm WaterSense faucet median across thousands of EPA-listed residential fixtures.

Does Crosswater Ltd US-WF131WNX cut utility costs noticeably for a 3-person household?

Yes: cutting 24,528 gallons/yr relative to 4.0 gpm hardware translates to ~$270/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with Crosswater Ltd US-WF131WNX?

Pairing Crosswater Ltd US-WF131WNX (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Crosswater Ltd US-WF131WNX require a municipal plumbing permit?

Like-for-like swaps using Crosswater Ltd US-WF131WNX on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What efficiency edge separates Crosswater Ltd US-WF131WNX from legacy and EPAct models?

Certified at 1.2 gpm, Crosswater Ltd US-WF131WNX achieves 45.5% savings against EPAct 1992 (2.2 gpm) and 70.0% savings against 4.0 gpm fixtures, 8,176 gallons per occupant yearly.

What supply pressure checks protect Crosswater Ltd US-WF131WNX spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.2 gpm trim.

Does Crosswater Ltd US-WF131WNX qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes Crosswater Ltd US-WF131WNX eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories