Skip to main content
Grant Estimator

FANTINI 1006WU WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · FANTINI (1 SKU)
Verified Specification Summary

Listed in EPA WaterSense files at 1.5 gpm, FANTINI 1006WU achieves #15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm and lowers household water use ~5,475 gal/yr (3 residents) against pre-1994 2.75 gpm fixtures. Compare EPA WaterSense certified flow metrics for FANTINI 1006WU WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.5 gpm
vs. EPAct 1992
-31.8% (2.2 gpm)
Annual Draw (1 Pers.)
2,190 gal/yr
Annual Saved vs. Legacy
1,825 gal/person
Brand EPA Count
78 faucets
Series / Variants
1006WU (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does FANTINI 1006WU Benchmark & Water Budget show?

Certified discharge for FANTINI 1006WU measures 1.5 gpm (aggressive sub-1.6 gpm conservation tier), standing #15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm (0.30 gpm higher-flow than the 1.20 gpm median) against the 2.2 gpm standard.

Pair this 1.5 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: FANTINI holds 78 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~5,475 gallons/yr—roughly $44/yr in low-tariff towns ($8/1k gal), $60/yr at national averages ($11/1k gal), or $99/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Fairfield (CA) list active rebates among 200 U.S. programs. Closest alternatives: AM Conservation Group, Inc. FA012CPB1WS (1.5 gpm) and Amazon 90457.05 (1.5 gpm).

Does FANTINI 1006WU beat the 1.2 gpm WaterSense faucet median?

Certified at 1.50 gpm, FANTINI 1006WU sits well under EPAct 1992 limits (2.2 gpm) across 22,471 EPA-registered faucets.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 1006WU: 1.50; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)1006WU: 1.501006WU1.50EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.5 gpm: 1.5 gpm (100th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.5 gpm: 1.5 gpm (P100)

Why check closet flange height and L/360 stiffness around FANTINI 1006WU?

Checking framing deflection (L/360) and finished tile-to-flange elevation before fixture mounting eliminates wobble and concealed floor leaks.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where does FANTINI 1006WU fit in EPA WaterSense files?

Review certified water flow, brand lineup breadth, and ASSE 1016 valve or IPC closet flange pairing guidelines for FANTINI 1006WU.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share FANTINI (78 certified) EPA WaterSense Partner
Model Number / Series 1006WU Certified Series (1 finish variants)
Rated Consumption 1.5 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Does FANTINI 1006WU lower water bills for larger households?

Review computed annual water totals for 1 to 4 residents comparing FANTINI 1006WU certified consumption with older pre-1994 residential plumbing hardware.

Computed annual water savings for FANTINI 1006WU (1.5 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,190 gal1,022 gal1,825 gal (~$20)
2 Occupants4,380 gal2,044 gal3,650 gal (~$40)
3 Occupants6,570 gal3,066 gal5,475 gal (~$44–$99)
4 Occupants8,760 gal4,088 gal7,300 gal (~$80)

How do similar WaterSense brands compare with FANTINI 1006WU?

Comparable certified models listed below share FANTINI 1006WU category standards while offering alternative brand warranties and rough-in configurations.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
AM Conservation Group, Inc. FA012CPB1WS 1.5 gpm (Same flow) WaterSense
Amazon 90457.05 1.5 gpm (Same flow) WaterSense
Aqueous™, Estora™ or Homewerks Worldwide 20-B41CY-Z 1.5 gpm (Same flow) WaterSense
Aqueous™, Estora™ or Homewerks Worldwide 30-B41WN-Z 1.5 gpm (Same flow) WaterSense
Brookfield 192-8268 1.5 gpm (Same flow) CMI 3252C Chrome Two Handle Deluxe...

How do local water rates change FANTINI 1006WU savings?

Use the local browser estimator below with your city water-sewer rate and household size to quantify FANTINI 1006WU yearly utility impact.

Does FANTINI 1006WU suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying FANTINI 1006WU for your remodel.

Limitations & Who Should Skip

  • Low static water supply pressure <30 PSI

Best-Fit Homeowner Profiles

  • Strong scenario: Claiming utility rebates across 200 U.S. WaterSense programs
  • Best application: Lowering household draw to 2,190 gal/person/yr

What should homeowners verify first about FANTINI 1006WU?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to FANTINI 1006WU.

What supply pressure checks protect FANTINI 1006WU spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.5 gpm trim.

Does FANTINI 1006WU qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes FANTINI 1006WU eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does FANTINI 1006WU rank against other certified faucets?

Rated at 1.5 gpm, FANTINI 1006WU measures slightly above the 1.2 gpm WaterSense faucet median across thousands of EPA-listed residential fixtures.

Does FANTINI 1006WU cut utility costs noticeably for a 3-person household?

Yes: cutting 21,900 gallons/yr relative to 4.0 gpm hardware translates to ~$241/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with FANTINI 1006WU?

Pairing FANTINI 1006WU (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing FANTINI 1006WU require a municipal plumbing permit?

Like-for-like swaps using FANTINI 1006WU on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What efficiency edge separates FANTINI 1006WU from legacy and EPAct models?

Certified at 1.5 gpm, FANTINI 1006WU achieves 31.8% savings against EPAct 1992 (2.2 gpm) and 62.5% savings against 4.0 gpm fixtures, 7,300 gallons per occupant yearly.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories