Skip to main content
Grant Estimator

FORTIS 92211LC_XX WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · FORTIS (1 SKU)
Verified Specification Summary

Operating at 1.2 gpm, the FORTIS 92211LC_XX faucet beats 1992 EPAct rules (2.2 gpm) by 45.5% (#1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets), saving a 3-resident home ~6,789 gallons annually compared to 2.75 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for FORTIS 92211LC_XX WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.2 gpm
vs. EPAct 1992
-45.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,752 gal/yr
Annual Saved vs. Legacy
2,263 gal/person
Brand EPA Count
11 faucets
Series / Variants
92211LC_XX (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does FORTIS 92211LC_XX Benchmark & Water Budget show?

WaterSense benchmark: FORTIS series 92211LC_XX verifies 1.2 gpm delivery, scoring 45.5% leaner than EPAct 1992 (2.2 gpm) at #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets.

Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: FORTIS holds 11 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).

How much leaner is FORTIS 92211LC_XX than pre-1994 2.75 gpm plumbing?

Flow distribution bars contrast FORTIS 92211LC_XX (1.20 gpm) directly with the 1.2 gpm WaterSense median and 2.75 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 92211LC_XX: 1.20; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)92211LC_XX: 1.2092211LC_XX1.20EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.2 gpm: 1.2 gpm (67th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.2 gpm: 1.2 gpm (P67)

Which framing and flange tolerances matter before installing FORTIS 92211LC_XX?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does FORTIS 92211LC_XX compare to WaterSense category caps?

Each specification row below documents FORTIS 92211LC_XX tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share FORTIS (11 certified) EPA WaterSense Partner
Model Number / Series 92211LC_XX Certified Series (1 finish variants)
Rated Consumption 1.2 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How many gallons per year does FORTIS 92211LC_XX cut?

Calculated annual water budgets below quantify FORTIS 92211LC_XX savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for FORTIS 92211LC_XX (1.2 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,752 gal1,460 gal2,263 gal (~$25)
2 Occupants3,504 gal2,920 gal4,526 gal (~$50)
3 Occupants5,256 gal4,380 gal6,789 gal (~$54–$122)
4 Occupants7,008 gal5,840 gal9,052 gal (~$100)

Which competing models share FORTIS 92211LC_XX flow tier?

Review five peer WaterSense units matching FORTIS 92211LC_XX conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 LUM211-PU 1.2 gpm (Same flow) Lumoni
Aidier ID-B3594 1.2 gpm (Same flow) WaterSense
Axor 48170xx1 1.2 gpm (Same flow) Axoror One
B&K 221-015 1.2 gpm (Same flow) Lavatory Faucet
B&K 222-311H 1.2 gpm (Same flow) Lavatory Faucet

Can you estimate FORTIS 92211LC_XX payback in your home?

Test how many gallons and dollars FORTIS 92211LC_XX saves each year by entering your household residents and local water-sewer rate below.

When does FORTIS 92211LC_XX fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering FORTIS 92211LC_XX.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Recommended when: Upgrading 2.75 gpm fixtures for 56.4% water reduction
  • Target scenario: Matching FORTIS SKU 92211LC_XX certification on rebate forms

How do federal and code standards apply to FORTIS 92211LC_XX?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for FORTIS 92211LC_XX.

How do 133 WaterSense rebate programs treat FORTIS 92211LC_XX?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like FORTIS 92211LC_XX, itemized purchase invoices, and residential installation addresses.

How does FORTIS 92211LC_XX perform relative to the EPA WaterSense category median?

Among certified WaterSense faucets, the national median stands at 1.2 gpm. At 1.2 gpm, FORTIS 92211LC_XX sits equal to the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to FORTIS 92211LC_XX?

At $11 per 1,000 gallons, a 3-person household conserving 24,528 gallons/yr with FORTIS 92211LC_XX trims roughly $270 annually off water and sewer utility bills.

What anti-scald valve standard pairs with FORTIS 92211LC_XX?

Pairing FORTIS 92211LC_XX (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing FORTIS 92211LC_XX require a municipal plumbing permit?

Like-for-like swaps using FORTIS 92211LC_XX on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What annual gallon reduction does FORTIS 92211LC_XX achieve over older plumbing?

Testing at 1.2 gpm, FORTIS 92211LC_XX uses 70.0% less water than 4.0 gpm pre-1994 models (45.5% below 2.2 gpm EPAct), conserving 8,176 gallons per resident each year.

When can FORTIS 92211LC_XX (1.2 gpm) underperform in an older bathroom?

Skip FORTIS 92211LC_XX without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories