Skip to main content
Grant Estimator

in2aqua 1222 1 20 2 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Lana (4 SKUs)
Verified Specification Summary

The in2aqua 1222 1 20 2 is an EPA WaterSense faucet certified at 1.2 gpm, 45.5% below EPAct 1992 (2.2 gpm) and #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets. A 3-person household saves ~6,789 gallons/yr replacing a 2.75 gpm legacy fixture. Compare EPA WaterSense certified flow metrics for in2aqua 1222 1 20 2 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.2 gpm
vs. EPAct 1992
-45.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,752 gal/yr
Annual Saved vs. Legacy
2,263 gal/person
Brand EPA Count
60 faucets
Series / Variants
1222 1 20 2 (4)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does in2aqua 1222 1 20 2 Benchmark & Water Budget show?

Flow standing: in2aqua 1222 1 20 2 (Lana) operates at 1.2 gpm (aggressive sub-1.6 gpm conservation tier), #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets, cutting 45.5% off EPAct 1992 (2.2 gpm).

Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: in2aqua holds 60 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).

How does in2aqua 1222 1 20 2 compare to EPAct 1992 and legacy gpm rates?

Tested at 1.20 gpm, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (2.2 gpm) and pre-1994 legacy units (2.75 gpm).

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 1222 1 20 2: 1.20; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)1222 1 20 2: 1.201222 1 20 21.20EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.2 gpm: 1.2 gpm (67th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.2 gpm: 1.2 gpm (P67)

What floor flatness and flange clearances pair with in2aqua 1222 1 20 2?

Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which EPA WaterSense test specs apply to in2aqua 1222 1 20 2?

Certified EPA WaterSense records for in2aqua 1222 1 20 2 verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share in2aqua (60 certified) EPA WaterSense Partner
Model Number / Series 1222 1 20 2 Lana (4 finish variants)
Rated Consumption 1.2 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 4 finish and trim SKUs share the in2aqua 1222 1 20 2 WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 4 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into in2aqua 1222 1 20 2 (4 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
1222 1 20 21.2 gpmLana
1222 1 00 21.2 gpmLana
1299 1 20 21.2 gpmLana
1299 1 00 21.2 gpmLana

How much water and money can in2aqua 1222 1 20 2 save each year?

Household projections below calculate in2aqua 1222 1 20 2 annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.

Computed annual water savings for in2aqua 1222 1 20 2 (1.2 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,752 gal1,460 gal2,263 gal (~$25)
2 Occupants3,504 gal2,920 gal4,526 gal (~$50)
3 Occupants5,256 gal4,380 gal6,789 gal (~$54–$122)
4 Occupants7,008 gal5,840 gal9,052 gal (~$100)

Which EPA WaterSense fixtures match in2aqua 1222 1 20 2?

Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 LUM211-PU 1.2 gpm (Same flow) Lumoni
Aidier ID-B3594 1.2 gpm (Same flow) WaterSense
Axor 48170xx1 1.2 gpm (Same flow) Axoror One
B&K 221-015 1.2 gpm (Same flow) Lavatory Faucet
B&K 222-311H 1.2 gpm (Same flow) Lavatory Faucet

How much does in2aqua 1222 1 20 2 save at your local water rate?

Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.

Where should contractors skip in2aqua 1222 1 20 2 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for in2aqua 1222 1 20 2 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Low static water supply pressure <30 PSI

Best-Fit Homeowner Profiles

  • Choose this if: Claiming utility rebates across 200 U.S. WaterSense programs
  • Works well for: Lowering household draw to 1,752 gal/person/yr

What key rules and numbers govern in2aqua 1222 1 20 2?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting in2aqua 1222 1 20 2.

How many gallons per person does in2aqua 1222 1 20 2 save annually?

Each resident saves ~8,176 gallons yearly (70.0% drop) replacing a 4.0 gpm fixture with in2aqua 1222 1 20 2 (1.2 gpm), or 2,920 gal/yr versus 2.2 gpm EPAct baselines.

Who should NOT install in2aqua 1222 1 20 2 without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.2 gpm faucet.

Can homeowners claim utility rebates when installing in2aqua 1222 1 20 2?

Because in2aqua 1222 1 20 2 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is in2aqua 1222 1 20 2 leaner than typical WaterSense faucet models?

Compared with the 1.2 gpm WaterSense faucet median, in2aqua 1222 1 20 2's 1.2 gpm rating places it equal to category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with in2aqua 1222 1 20 2?

Upgrading a 4.0 gpm legacy fixture to in2aqua 1222 1 20 2 saves ~24,528 gallons yearly for three occupants, about $270/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with in2aqua 1222 1 20 2?

Pairing in2aqua 1222 1 20 2 (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing in2aqua 1222 1 20 2 require a municipal plumbing permit?

Like-for-like swaps using in2aqua 1222 1 20 2 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories