Skip to main content
Grant Estimator

Jaclo 6870-T689-1.2 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Astor w/ ball handle (2 SKUs)
Verified Specification Summary

Certified under EPA WaterSense, Jaclo 6870-T689-1.2 tests at 1.2 gpm (#1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets), trimming 45.5% off the 2.2 gpm federal cap while cutting 3-person household draw by ~6,789 gal/yr versus 2.75 gpm fixtures. Compare EPA WaterSense certified flow metrics for Jaclo 6870-T689-1.2 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.2 gpm
vs. EPAct 1992
-45.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,752 gal/yr
Annual Saved vs. Legacy
2,263 gal/person
Brand EPA Count
251 faucets
Series / Variants
6870-T689-1.2 (2)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Jaclo 6870-T689-1.2 Benchmark & Water Budget show?

Efficiency check: certified at 1.2 gpm, Jaclo 6870-T689-1.2 (Astor w/ ball handle) trims 45.5% under federal 2.2 gpm caps; #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets.

Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Jaclo holds 251 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as California Water Service Company (CA) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).

Where does Jaclo 6870-T689-1.2 sit on the EPA WaterSense faucet flow curve?

Comparing Jaclo 6870-T689-1.2 (1.20 gpm) against federal EPAct (2.2 gpm) and legacy (2.75 gpm) baselines shows immediate per-use conservation.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 6870-T689-1.2: 1.20; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)6870-T689-1.2: 1.206870-T689-1.21.20EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.2 gpm: 1.2 gpm (67th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.2 gpm: 1.2 gpm (P67)

How do subfloor levelness and rough-in height protect Jaclo 6870-T689-1.2?

Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What official WaterSense figures verify Jaclo 6870-T689-1.2?

Examine Jaclo 6870-T689-1.2 certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Jaclo (251 certified) EPA WaterSense Partner
Model Number / Series 6870-T689-1.2 Astor w/ ball handle (2 finish variants)
Rated Consumption 1.2 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 2 finish and trim SKUs share the Jaclo 6870-T689-1.2 WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 2 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Jaclo 6870-T689-1.2 (2 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
6870-T689-1.2-***1.2 gpmAstor w/ ball handle
6870-T687-1.2-***1.2 gpmAstor w/ ball handle

What annual utility savings does Jaclo 6870-T689-1.2 deliver?

Compare 1-to-4-person household water use with Jaclo 6870-T689-1.2 against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.

Computed annual water savings for Jaclo 6870-T689-1.2 (1.2 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,752 gal1,460 gal2,263 gal (~$25)
2 Occupants3,504 gal2,920 gal4,526 gal (~$50)
3 Occupants5,256 gal4,380 gal6,789 gal (~$54–$122)
4 Occupants7,008 gal5,840 gal9,052 gal (~$100)

What alternative WaterSense models compare to Jaclo 6870-T689-1.2?

Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 LUM211-PU 1.2 gpm (Same flow) Lumoni
Aidier ID-B3594 1.2 gpm (Same flow) WaterSense
Axor 48170xx1 1.2 gpm (Same flow) Axoror One
B&K 221-015 1.2 gpm (Same flow) Lavatory Faucet
B&K 222-311H 1.2 gpm (Same flow) Lavatory Faucet

What will Jaclo 6870-T689-1.2 save on your annual water bill?

Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.

What plumbing or duct constraints rule out Jaclo 6870-T689-1.2?

Compare where Jaclo 6870-T689-1.2 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Homeowner profile: Meeting 2.2 gpm federal & stricter WaterSense caps
  • Suited to: Targeting ~$75/yr utility savings (3-person home)

Which homeowner questions come up most for Jaclo 6870-T689-1.2?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Jaclo 6870-T689-1.2.

How does Jaclo 6870-T689-1.2 perform relative to the EPA WaterSense category median?

Among certified WaterSense faucets, the national median stands at 1.2 gpm. At 1.2 gpm, Jaclo 6870-T689-1.2 sits equal to the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Jaclo 6870-T689-1.2?

At $11 per 1,000 gallons, a 3-person household conserving 24,528 gallons/yr with Jaclo 6870-T689-1.2 trims roughly $270 annually off water and sewer utility bills.

What anti-scald valve standard pairs with Jaclo 6870-T689-1.2?

Pairing Jaclo 6870-T689-1.2 (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Jaclo 6870-T689-1.2 require a municipal plumbing permit?

Like-for-like swaps using Jaclo 6870-T689-1.2 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 4.0 gpm fixture to Jaclo 6870-T689-1.2 at 1.2 gpm?

Swapping a 4.0 gpm unit for Jaclo 6870-T689-1.2 slashes water draw 70.0% (8,176 gal/person/yr), beating 2.2 gpm federal EPAct standards by 45.5%.

When can Jaclo 6870-T689-1.2 (1.2 gpm) underperform in an older bathroom?

Skip Jaclo 6870-T689-1.2 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat Jaclo 6870-T689-1.2?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Jaclo 6870-T689-1.2, itemized purchase invoices, and residential installation addresses.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories