Skip to main content
Grant Estimator

Jandon 3223C WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Jandon (1 SKU)
Verified Specification Summary

Listed in EPA WaterSense files at 1.5 gpm, Jandon 3223C achieves #15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm and lowers household water use ~5,475 gal/yr (3 residents) against pre-1994 2.75 gpm fixtures. Compare EPA WaterSense certified flow metrics for Jandon 3223C WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.5 gpm
vs. EPAct 1992
-31.8% (2.2 gpm)
Annual Draw (1 Pers.)
2,190 gal/yr
Annual Saved vs. Legacy
1,825 gal/person
Brand EPA Count
27 faucets
Series / Variants
3223C (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Jandon 3223C Benchmark & Water Budget show?

Certified discharge for Jandon 3223C measures 1.5 gpm (aggressive sub-1.6 gpm conservation tier), standing #15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm (0.30 gpm higher-flow than the 1.20 gpm median) against the 2.2 gpm standard.

Pair this 1.5 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Jandon holds 27 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~5,475 gallons/yr—roughly $44/yr in low-tariff towns ($8/1k gal), $60/yr at national averages ($11/1k gal), or $99/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: AM Conservation Group, Inc. FA012CPB1WS (1.5 gpm) and Amazon 90457.05 (1.5 gpm).

Does Jandon 3223C beat the 1.2 gpm WaterSense faucet median?

Certified at 1.50 gpm, Jandon 3223C sits well under EPAct 1992 limits (2.2 gpm) across 22,471 EPA-registered faucets.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 3223C: 1.50; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)3223C: 1.503223C1.50EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.5 gpm: 1.5 gpm (100th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.5 gpm: 1.5 gpm (P100)

Why check closet flange height and L/360 stiffness around Jandon 3223C?

Checking framing deflection (L/360) and finished tile-to-flange elevation before fixture mounting eliminates wobble and concealed floor leaks.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Where does Jandon 3223C fit in EPA WaterSense files?

Review certified water flow, brand lineup breadth, and ASSE 1016 valve or IPC closet flange pairing guidelines for Jandon 3223C.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Jandon (27 certified) EPA WaterSense Partner
Model Number / Series 3223C Certified Series (1 finish variants)
Rated Consumption 1.5 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Does Jandon 3223C lower water bills for larger households?

Review computed annual water totals for 1 to 4 residents comparing Jandon 3223C certified consumption with older pre-1994 residential plumbing hardware.

Computed annual water savings for Jandon 3223C (1.5 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,190 gal1,022 gal1,825 gal (~$20)
2 Occupants4,380 gal2,044 gal3,650 gal (~$40)
3 Occupants6,570 gal3,066 gal5,475 gal (~$44–$99)
4 Occupants8,760 gal4,088 gal7,300 gal (~$80)

How do similar WaterSense brands compare with Jandon 3223C?

Comparable certified models listed below share Jandon 3223C category standards while offering alternative brand warranties and rough-in configurations.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
AM Conservation Group, Inc. FA012CPB1WS 1.5 gpm (Same flow) WaterSense
Amazon 90457.05 1.5 gpm (Same flow) WaterSense
Aqueous™, Estora™ or Homewerks Worldwide 20-B41CY-Z 1.5 gpm (Same flow) WaterSense
Aqueous™, Estora™ or Homewerks Worldwide 30-B41WN-Z 1.5 gpm (Same flow) WaterSense
Brookfield 192-8268 1.5 gpm (Same flow) CMI 3252C Chrome Two Handle Deluxe...

How do local water rates change Jandon 3223C savings?

Use the local browser estimator below with your city water-sewer rate and household size to quantify Jandon 3223C yearly utility impact.

When does Jandon 3223C fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Jandon 3223C.

Limitations & Who Should Skip

  • Low static water supply pressure <30 PSI

Best-Fit Homeowner Profiles

  • Recommended when: Claiming utility rebates across 200 U.S. WaterSense programs
  • Target scenario: Lowering household draw to 2,190 gal/person/yr

What should homeowners verify first about Jandon 3223C?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Jandon 3223C.

How does Jandon 3223C perform relative to the EPA WaterSense category median?

Among certified WaterSense faucets, the national median stands at 1.2 gpm. At 1.5 gpm, Jandon 3223C sits slightly above the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Jandon 3223C?

At $11 per 1,000 gallons, a 3-person household conserving 21,900 gallons/yr with Jandon 3223C trims roughly $241 annually off water and sewer utility bills.

What anti-scald valve standard pairs with Jandon 3223C?

Pairing Jandon 3223C (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Jandon 3223C require a municipal plumbing permit?

Like-for-like swaps using Jandon 3223C on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What annual gallon reduction does Jandon 3223C achieve over older plumbing?

Testing at 1.5 gpm, Jandon 3223C uses 62.5% less water than 4.0 gpm pre-1994 models (31.8% below 2.2 gpm EPAct), conserving 7,300 gallons per resident each year.

When can Jandon 3223C (1.5 gpm) underperform in an older bathroom?

Skip Jandon 3223C without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat Jandon 3223C?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Jandon 3223C, itemized purchase invoices, and residential installation addresses.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories