Certified under EPA WaterSense, Kangkang 10010-91 tests at 1.5 gpm (#15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm), trimming 31.8% off the 2.2 gpm federal cap while cutting 3-person household draw by ~5,475 gal/yr versus 2.75 gpm fixtures. Compare EPA WaterSense certified flow metrics for Kangkang 10010-91 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.5 gpm
- vs. EPAct 1992
- -31.8% (2.2 gpm)
- Annual Draw (1 Pers.)
- 2,190 gal/yr
- Annual Saved vs. Legacy
- 1,825 gal/person
- Brand EPA Count
- 16 faucets
- Series / Variants
- 10010-91 (1)

What does Kangkang 10010-91 Benchmark & Water Budget show?
Efficiency check: certified at 1.5 gpm, Kangkang 10010-91 trims 31.8% under federal 2.2 gpm caps; #15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm (0.30 gpm higher-flow than the 1.20 gpm median).
Pair this 1.5 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.
Brand breadth: Kangkang holds 16 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~5,475 gallons/yr—roughly $44/yr in low-tariff towns ($8/1k gal), $60/yr at national averages ($11/1k gal), or $99/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Tucson - Tucson Water (AZ) list active rebates among 200 U.S. programs. Closest alternatives: AM Conservation Group, Inc. FA012CPB1WS (1.5 gpm) and Amazon 90457.05 (1.5 gpm).
Where does Kangkang 10010-91 sit on the EPA WaterSense faucet flow curve?
Comparing Kangkang 10010-91 (1.50 gpm) against federal EPAct (2.2 gpm) and legacy (2.75 gpm) baselines shows immediate per-use conservation.
How do subfloor levelness and rough-in height protect Kangkang 10010-91?
Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.
What official WaterSense figures verify Kangkang 10010-91?
Examine Kangkang 10010-91 certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | Kangkang (16 certified) | EPA WaterSense Partner |
| Model Number / Series | 10010-91 | Certified Series (1 finish variants) |
| Rated Consumption | 1.5 gpm | Category median 1.2 gpm (n=22,471 rated) |
| Shower / Faucet Pairing | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |
What annual utility savings does Kangkang 10010-91 deliver?
Compare 1-to-4-person household water use with Kangkang 10010-91 against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 2,190 gal | 1,022 gal | 1,825 gal (~$20) |
| 2 Occupants | 4,380 gal | 2,044 gal | 3,650 gal (~$40) |
| 3 Occupants | 6,570 gal | 3,066 gal | 5,475 gal (~$44–$99) |
| 4 Occupants | 8,760 gal | 4,088 gal | 7,300 gal (~$80) |
What alternative WaterSense models compare to Kangkang 10010-91?
Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.
| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| AM Conservation Group, Inc. FA012CPB1WS | 1.5 gpm (Same flow) | WaterSense |
| Amazon 90457.05 | 1.5 gpm (Same flow) | WaterSense |
| Aqueous™, Estora™ or Homewerks Worldwide 20-B41CY-Z | 1.5 gpm (Same flow) | WaterSense |
| Aqueous™, Estora™ or Homewerks Worldwide 30-B41WN-Z | 1.5 gpm (Same flow) | WaterSense |
| Brookfield 192-8268 | 1.5 gpm (Same flow) | CMI 3252C Chrome Two Handle Deluxe... |
What will Kangkang 10010-91 save on your annual water bill?
Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.
Who should not install Kangkang 10010-91 in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Kangkang 10010-91 for residential use.
Limitations & Who Should Skip
- Existing shower valve lacks ASSE 1016 pressure balancing
Best-Fit Homeowner Profiles
- Ideal fit: Meeting 2.2 gpm federal & stricter WaterSense caps
- Primary match: Targeting ~$60/yr utility savings (3-person home)
Which homeowner questions come up most for Kangkang 10010-91?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Kangkang 10010-91.
Is Kangkang 10010-91 leaner than typical WaterSense faucet models?
Compared with the 1.2 gpm WaterSense faucet median, Kangkang 10010-91's 1.5 gpm rating places it slightly above category norms inside EPA conservation limits.
What annual dollar savings can a 3-person home expect with Kangkang 10010-91?
Upgrading a 4.0 gpm legacy fixture to Kangkang 10010-91 saves ~21,900 gallons yearly for three occupants, about $241/yr at $11 per 1,000 gallons combined water and sewer.
What anti-scald valve standard pairs with Kangkang 10010-91?
Pairing Kangkang 10010-91 (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.
How is EPA WaterSense performance tested beyond raw gpm flow caps?
EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.
Does installing Kangkang 10010-91 require a municipal plumbing permit?
Like-for-like swaps using Kangkang 10010-91 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
How much water does Kangkang 10010-91 save compared with EPAct 1992 and pre-1994 fixtures?
Rated at 1.5 gpm, Kangkang 10010-91 cuts 31.8% below the 2.2 gpm EPAct 1992 ceiling and 62.5% under 4.0 gpm legacy units, saving 7,300 gal/person/yr (2,044 vs EPAct).
Who should NOT install Kangkang 10010-91 without checking house plumbing first?
Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.5 gpm faucet.
Can homeowners claim utility rebates when installing Kangkang 10010-91?
Because Kangkang 10010-91 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)