Skip to main content
Grant Estimator

LULANI BA-460-04xx WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · LULANI (3 SKUs)
Verified Specification Summary

Homeowners upgrading older 2.75 gpm plumbing to LULANI BA-460-04xx (1.2 gpm, #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets) cut 56.4% off legacy draw, conserving ~6,789 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for LULANI BA-460-04xx WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.2 gpm
vs. EPAct 1992
-45.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,752 gal/yr
Annual Saved vs. Legacy
2,263 gal/person
Brand EPA Count
20 faucets
Series / Variants
BA-460-04xx (3)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does LULANI BA-460-04xx Benchmark & Water Budget show?

Laboratory testing places LULANI BA-460-04xx at 1.2 gpm (aggressive sub-1.6 gpm conservation tier), saving 45.5% vs. EPAct 1992 (2.2 gpm) while ranking #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets.

Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: LULANI holds 20 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).

How do federal gpm limits contrast with LULANI BA-460-04xx tested flow?

Each bar isolates LULANI BA-460-04xx (1.20 gpm) relative to the EPA cap, federal EPAct 1992 standard (2.2 gpm), and pre-1994 draw.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): BA-460-04xx: 1.20; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)BA-460-04xx: 1.20BA-460-04xx1.20EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.2 gpm: 1.2 gpm (67th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.2 gpm: 1.2 gpm (P67)

How does wet-zone tile prep interact with LULANI BA-460-04xx rough-ins?

Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What plumbing standards accompany LULANI BA-460-04xx installation?

Verify LULANI BA-460-04xx EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share LULANI (20 certified) EPA WaterSense Partner
Model Number / Series BA-460-04xx Certified Series (3 finish variants)
Rated Consumption 1.2 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 3 finish and trim SKUs share the LULANI BA-460-04xx WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 3 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into LULANI BA-460-04xx (3 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
BA-460-04xx1.2 gpmShared Series Spec
BA-460-03xx1.2 gpmShared Series Spec
BA-460-05xx1.2 gpmShared Series Spec

What household water budget fits LULANI BA-460-04xx?

Annual consumption rows below translate LULANI BA-460-04xx certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.

Computed annual water savings for LULANI BA-460-04xx (1.2 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,752 gal1,460 gal2,263 gal (~$25)
2 Occupants3,504 gal2,920 gal4,526 gal (~$50)
3 Occupants5,256 gal4,380 gal6,789 gal (~$54–$122)
4 Occupants7,008 gal5,840 gal9,052 gal (~$100)

Where can buyers find alternatives to LULANI BA-460-04xx?

Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 LUM211-PU 1.2 gpm (Same flow) Lumoni
Aidier ID-B3594 1.2 gpm (Same flow) WaterSense
Axor 48170xx1 1.2 gpm (Same flow) Axoror One
B&K 221-015 1.2 gpm (Same flow) Lavatory Faucet
B&K 222-311H 1.2 gpm (Same flow) Lavatory Faucet

What annual bill drop does LULANI BA-460-04xx achieve for your family?

Calculate annual gallons conserved and dollar savings for LULANI BA-460-04xx using your exact occupant count and utility tariff without submitting personal info.

Who should not install LULANI BA-460-04xx in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting LULANI BA-460-04xx for residential use.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Ideal fit: Meeting 2.2 gpm federal & stricter WaterSense caps
  • Primary match: Targeting ~$75/yr utility savings (3-person home)

Which code checks and cost facts matter for LULANI BA-460-04xx?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to LULANI BA-460-04xx.

What annual dollar savings can a 3-person home expect with LULANI BA-460-04xx?

Upgrading a 4.0 gpm legacy fixture to LULANI BA-460-04xx saves ~24,528 gallons yearly for three occupants, about $270/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with LULANI BA-460-04xx?

Pairing LULANI BA-460-04xx (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing LULANI BA-460-04xx require a municipal plumbing permit?

Like-for-like swaps using LULANI BA-460-04xx on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How much water does LULANI BA-460-04xx save compared with EPAct 1992 and pre-1994 fixtures?

Rated at 1.2 gpm, LULANI BA-460-04xx cuts 45.5% below the 2.2 gpm EPAct 1992 ceiling and 70.0% under 4.0 gpm legacy units, saving 8,176 gal/person/yr (2,920 vs EPAct).

Who should NOT install LULANI BA-460-04xx without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.2 gpm faucet.

Can homeowners claim utility rebates when installing LULANI BA-460-04xx?

Because LULANI BA-460-04xx holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is LULANI BA-460-04xx leaner than typical WaterSense faucet models?

Compared with the 1.2 gpm WaterSense faucet median, LULANI BA-460-04xx's 1.2 gpm rating places it equal to category norms inside EPA conservation limits.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories