The Luxart™ A271-PU is an EPA WaterSense faucet certified at 1.5 gpm, 31.8% below EPAct 1992 (2.2 gpm) and #15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm. A 3-person household saves ~5,475 gallons/yr replacing a 2.75 gpm legacy fixture. Compare EPA WaterSense certified flow metrics for Luxart™ A271-PU WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.5 gpm
- vs. EPAct 1992
- -31.8% (2.2 gpm)
- Annual Draw (1 Pers.)
- 2,190 gal/yr
- Annual Saved vs. Legacy
- 1,825 gal/person
- Brand EPA Count
- 28 faucets
- Series / Variants
- A271-PU (1)

What does Luxart™ A271-PU Benchmark & Water Budget show?
Flow standing: Luxart™ A271-PU operates at 1.5 gpm (aggressive sub-1.6 gpm conservation tier), #15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm (0.30 gpm higher-flow than the 1.20 gpm median), cutting 31.8% off EPAct 1992 (2.2 gpm).
Pair this 1.5 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.
Brand breadth: Luxart™ holds 28 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~5,475 gallons/yr—roughly $44/yr in low-tariff towns ($8/1k gal), $60/yr at national averages ($11/1k gal), or $99/yr in high-rate cities ($18/1k gal). Regional utilities such as California Water Service Company (CA) list active rebates among 200 U.S. programs. Closest alternatives: AM Conservation Group, Inc. FA012CPB1WS (1.5 gpm) and Amazon 90457.05 (1.5 gpm).
How does Luxart™ A271-PU compare to EPAct 1992 and legacy gpm rates?
Tested at 1.50 gpm, this fixture uses substantially less water per cycle than 1992 EPAct ceilings (2.2 gpm) and pre-1994 legacy units (2.75 gpm).
What floor flatness and flange clearances pair with Luxart™ A271-PU?
Self-leveling concrete requires acrylic primer over stiffened L/360 framing, and closet flanges must bolt flush atop finished tile to keep wax or waxless seals watertight.
Which EPA WaterSense test specs apply to Luxart™ A271-PU?
Certified EPA WaterSense records for Luxart™ A271-PU verify maximum flow performance, model-series identifiers, and residential plumbing code pairing rules below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | Luxart™ (28 certified) | EPA WaterSense Partner |
| Model Number / Series | A271-PU | Certified Series (1 finish variants) |
| Rated Consumption | 1.5 gpm | Category median 1.2 gpm (n=22,471 rated) |
| Shower / Faucet Pairing | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |
How much water and money can Luxart™ A271-PU save each year?
Household projections below calculate Luxart™ A271-PU annual gallon draw and estimated utility savings across 1 to 4 occupants versus legacy and EPAct fixtures.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 2,190 gal | 1,022 gal | 1,825 gal (~$20) |
| 2 Occupants | 4,380 gal | 2,044 gal | 3,650 gal (~$40) |
| 3 Occupants | 6,570 gal | 3,066 gal | 5,475 gal (~$44–$99) |
| 4 Occupants | 8,760 gal | 4,088 gal | 7,300 gal (~$80) |
Which EPA WaterSense fixtures match Luxart™ A271-PU?
Five comparable EPA WaterSense certified models across competing manufacturers appear below with exact flow rate differences for bid substitution checks.
| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| AM Conservation Group, Inc. FA012CPB1WS | 1.5 gpm (Same flow) | WaterSense |
| Amazon 90457.05 | 1.5 gpm (Same flow) | WaterSense |
| Aqueous™, Estora™ or Homewerks Worldwide 20-B41CY-Z | 1.5 gpm (Same flow) | WaterSense |
| Aqueous™, Estora™ or Homewerks Worldwide 30-B41WN-Z | 1.5 gpm (Same flow) | WaterSense |
| Brookfield 192-8268 | 1.5 gpm (Same flow) | CMI 3252C Chrome Two Handle Deluxe... |
How much does Luxart™ A271-PU save at your local water rate?
Enter your household occupant count and combined water-sewer tariff per 1,000 gallons below to estimate annual savings privately in browser.
Where should contractors skip Luxart™ A271-PU on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Luxart™ A271-PU carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Low static water supply pressure <30 PSI
Best-Fit Homeowner Profiles
- Choose this if: Claiming utility rebates across 200 U.S. WaterSense programs
- Works well for: Lowering household draw to 2,190 gal/person/yr
What key rules and numbers govern Luxart™ A271-PU?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Luxart™ A271-PU.
Can homeowners claim utility rebates when installing Luxart™ A271-PU?
Because Luxart™ A271-PU holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.
Is Luxart™ A271-PU leaner than typical WaterSense faucet models?
Compared with the 1.2 gpm WaterSense faucet median, Luxart™ A271-PU's 1.5 gpm rating places it slightly above category norms inside EPA conservation limits.
What annual dollar savings can a 3-person home expect with Luxart™ A271-PU?
Upgrading a 4.0 gpm legacy fixture to Luxart™ A271-PU saves ~21,900 gallons yearly for three occupants, about $241/yr at $11 per 1,000 gallons combined water and sewer.
What anti-scald valve standard pairs with Luxart™ A271-PU?
Pairing Luxart™ A271-PU (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.
How is EPA WaterSense performance tested beyond raw gpm flow caps?
EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.
Does installing Luxart™ A271-PU require a municipal plumbing permit?
Like-for-like swaps using Luxart™ A271-PU on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
How many gallons per person does Luxart™ A271-PU save annually?
Each resident saves ~7,300 gallons yearly (62.5% drop) replacing a 4.0 gpm fixture with Luxart™ A271-PU (1.5 gpm), or 2,044 gal/yr versus 2.2 gpm EPAct baselines.
Who should NOT install Luxart™ A271-PU without checking house plumbing first?
Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.5 gpm faucet.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)