Skip to main content
Grant Estimator

Noken 100283554-N197503813 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · LIGNAGE (10 SKUs)
Verified Specification Summary

Homeowners upgrading older 2.75 gpm plumbing to Noken 100283554-N197503813 (1.2 gpm, #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets) cut 56.4% off legacy draw, conserving ~6,789 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for Noken 100283554-N197503813 WaterSense Faucet, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.2 gpm
vs. EPAct 1992
-45.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,752 gal/yr
Annual Saved vs. Legacy
2,263 gal/person
Brand EPA Count
29 faucets
Series / Variants
100283554-N197503813 (10)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Noken 100283554-N197503813 Benchmark & Water Budget show?

Laboratory testing places Noken 100283554-N197503813 (LIGNAGE) at 1.2 gpm (aggressive sub-1.6 gpm conservation tier), saving 45.5% vs. EPAct 1992 (2.2 gpm) while ranking #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets.

Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Noken holds 29 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as Big Bear Lake Department of Water and Power (CA) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).

How do federal gpm limits contrast with Noken 100283554-N197503813 tested flow?

Each bar isolates Noken 100283554-N197503813 (1.20 gpm) relative to the EPA cap, federal EPAct 1992 standard (2.2 gpm), and pre-1994 draw.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 100283554-N197503813: 1.20; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)100283554-N197503813: 1.20100283554-N1975038131.20EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.2 gpm: 1.2 gpm (67th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.2 gpm: 1.2 gpm (P67)

How does wet-zone tile prep interact with Noken 100283554-N197503813 rough-ins?

Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What plumbing standards accompany Noken 100283554-N197503813 installation?

Verify Noken 100283554-N197503813 EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Noken (29 certified) EPA WaterSense Partner
Model Number / Series 100283554-N197503813 LIGNAGE (10 finish variants)
Rated Consumption 1.2 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 10 finish and trim SKUs share the Noken 100283554-N197503813 WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 8 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Noken 100283554-N197503813 (10 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
100283554-N1975038131.2 gpmLIGNAGE
100283561-N1975038101.2 gpmLIGNAGE
100283546-N1975038141.2 gpmLIGNAGE
100283570-N1975038151.2 gpmLIGNAGE
100283551-N1975038071.2 gpmLIGNAGE
100283560-N1975038081.2 gpmLIGNAGE
100283553-N1975038051.2 gpmLIGNAGE
100283505-N1975038111.2 gpmLIGNAGE

What household water budget fits Noken 100283554-N197503813?

Annual consumption rows below translate Noken 100283554-N197503813 certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.

Computed annual water savings for Noken 100283554-N197503813 (1.2 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,752 gal1,460 gal2,263 gal (~$25)
2 Occupants3,504 gal2,920 gal4,526 gal (~$50)
3 Occupants5,256 gal4,380 gal6,789 gal (~$54–$122)
4 Occupants7,008 gal5,840 gal9,052 gal (~$100)

Where can buyers find alternatives to Noken 100283554-N197503813?

Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 LUM211-PU 1.2 gpm (Same flow) Lumoni
Aidier ID-B3594 1.2 gpm (Same flow) WaterSense
Axor 48170xx1 1.2 gpm (Same flow) Axoror One
B&K 221-015 1.2 gpm (Same flow) Lavatory Faucet
B&K 222-311H 1.2 gpm (Same flow) Lavatory Faucet

What annual bill drop does Noken 100283554-N197503813 achieve for your family?

Calculate annual gallons conserved and dollar savings for Noken 100283554-N197503813 using your exact occupant count and utility tariff without submitting personal info.

When does Noken 100283554-N197503813 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Noken 100283554-N197503813.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Recommended when: Meeting 2.2 gpm federal & stricter WaterSense caps
  • Target scenario: Targeting ~$75/yr utility savings (3-person home)

Which code checks and cost facts matter for Noken 100283554-N197503813?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Noken 100283554-N197503813.

What annual gallon reduction does Noken 100283554-N197503813 achieve over older plumbing?

Testing at 1.2 gpm, Noken 100283554-N197503813 uses 70.0% less water than 4.0 gpm pre-1994 models (45.5% below 2.2 gpm EPAct), conserving 8,176 gallons per resident each year.

When can Noken 100283554-N197503813 (1.2 gpm) underperform in an older bathroom?

Skip Noken 100283554-N197503813 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat Noken 100283554-N197503813?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Noken 100283554-N197503813, itemized purchase invoices, and residential installation addresses.

How does Noken 100283554-N197503813 perform relative to the EPA WaterSense category median?

Among certified WaterSense faucets, the national median stands at 1.2 gpm. At 1.2 gpm, Noken 100283554-N197503813 sits equal to the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Noken 100283554-N197503813?

At $11 per 1,000 gallons, a 3-person household conserving 24,528 gallons/yr with Noken 100283554-N197503813 trims roughly $270 annually off water and sewer utility bills.

What anti-scald valve standard pairs with Noken 100283554-N197503813?

Pairing Noken 100283554-N197503813 (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Noken 100283554-N197503813 require a municipal plumbing permit?

Like-for-like swaps using Noken 100283554-N197503813 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories