Skip to main content
Grant Estimator

Oxygenics 3809989 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · ALLEN + ROTH (3 SKUs)
Verified Specification Summary

Homeowners upgrading older 2.75 gpm plumbing to Oxygenics 3809989 (1.2 gpm, #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets) cut 56.4% off legacy draw, conserving ~6,789 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for Oxygenics 3809989 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.2 gpm
vs. EPAct 1992
-45.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,752 gal/yr
Annual Saved vs. Legacy
2,263 gal/person
Brand EPA Count
10 faucets
Series / Variants
3809989 (3)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Oxygenics 3809989 Benchmark & Water Budget show?

Laboratory testing places Oxygenics 3809989 (ALLEN + ROTH) at 1.2 gpm (aggressive sub-1.6 gpm conservation tier), saving 45.5% vs. EPAct 1992 (2.2 gpm) while ranking #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets.

Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Oxygenics holds 10 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as California Water Service Company (CA) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).

How do federal gpm limits contrast with Oxygenics 3809989 tested flow?

Each bar isolates Oxygenics 3809989 (1.20 gpm) relative to the EPA cap, federal EPAct 1992 standard (2.2 gpm), and pre-1994 draw.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 3809989: 1.20; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)3809989: 1.2038099891.20EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.2 gpm: 1.2 gpm (67th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.2 gpm: 1.2 gpm (P67)

How does wet-zone tile prep interact with Oxygenics 3809989 rough-ins?

Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What plumbing standards accompany Oxygenics 3809989 installation?

Verify Oxygenics 3809989 EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Oxygenics (10 certified) EPA WaterSense Partner
Model Number / Series 3809989 ALLEN + ROTH (3 finish variants)
Rated Consumption 1.2 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

Which 3 finish and trim SKUs share the Oxygenics 3809989 WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 3 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Oxygenics 3809989 (3 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
38099891.2 gpmALLEN + ROTH
38099911.2 gpmALLEN + ROTH
38099901.2 gpmALLEN + ROTH

What household water budget fits Oxygenics 3809989?

Annual consumption rows below translate Oxygenics 3809989 certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.

Computed annual water savings for Oxygenics 3809989 (1.2 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,752 gal1,460 gal2,263 gal (~$25)
2 Occupants3,504 gal2,920 gal4,526 gal (~$50)
3 Occupants5,256 gal4,380 gal6,789 gal (~$54–$122)
4 Occupants7,008 gal5,840 gal9,052 gal (~$100)

Where can buyers find alternatives to Oxygenics 3809989?

Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 LUM211-PU 1.2 gpm (Same flow) Lumoni
Aidier ID-B3594 1.2 gpm (Same flow) WaterSense
Axor 48170xx1 1.2 gpm (Same flow) Axoror One
B&K 221-015 1.2 gpm (Same flow) Lavatory Faucet
B&K 222-311H 1.2 gpm (Same flow) Lavatory Faucet

What annual bill drop does Oxygenics 3809989 achieve for your family?

Calculate annual gallons conserved and dollar savings for Oxygenics 3809989 using your exact occupant count and utility tariff without submitting personal info.

What plumbing or duct constraints rule out Oxygenics 3809989?

Compare where Oxygenics 3809989 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Homeowner profile: Meeting 2.2 gpm federal & stricter WaterSense caps
  • Suited to: Targeting ~$75/yr utility savings (3-person home)

Which code checks and cost facts matter for Oxygenics 3809989?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Oxygenics 3809989.

How does Oxygenics 3809989 perform relative to the EPA WaterSense category median?

Among certified WaterSense faucets, the national median stands at 1.2 gpm. At 1.2 gpm, Oxygenics 3809989 sits equal to the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Oxygenics 3809989?

At $11 per 1,000 gallons, a 3-person household conserving 24,528 gallons/yr with Oxygenics 3809989 trims roughly $270 annually off water and sewer utility bills.

What anti-scald valve standard pairs with Oxygenics 3809989?

Pairing Oxygenics 3809989 (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Oxygenics 3809989 require a municipal plumbing permit?

Like-for-like swaps using Oxygenics 3809989 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 4.0 gpm fixture to Oxygenics 3809989 at 1.2 gpm?

Swapping a 4.0 gpm unit for Oxygenics 3809989 slashes water draw 70.0% (8,176 gal/person/yr), beating 2.2 gpm federal EPAct standards by 45.5%.

When can Oxygenics 3809989 (1.2 gpm) underperform in an older bathroom?

Skip Oxygenics 3809989 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat Oxygenics 3809989?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Oxygenics 3809989, itemized purchase invoices, and residential installation addresses.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories