Skip to main content
Grant Estimator

PHOENIX PF232301 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · PHOENIX (1 SKU)
Verified Specification Summary

Operating at 1.2 gpm, the PHOENIX PF232301 faucet beats 1992 EPAct rules (2.2 gpm) by 45.5% (#1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets), saving a 3-resident home ~6,789 gallons annually compared to 2.75 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for PHOENIX PF232301 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.2 gpm
vs. EPAct 1992
-45.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,752 gal/yr
Annual Saved vs. Legacy
2,263 gal/person
Brand EPA Count
14 faucets
Series / Variants
PF232301 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does PHOENIX PF232301 Benchmark & Water Budget show?

WaterSense benchmark: PHOENIX series PF232301 verifies 1.2 gpm delivery, scoring 45.5% leaner than EPAct 1992 (2.2 gpm) at #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets.

Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: PHOENIX holds 14 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).

How much leaner is PHOENIX PF232301 than pre-1994 2.75 gpm plumbing?

Flow distribution bars contrast PHOENIX PF232301 (1.20 gpm) directly with the 1.2 gpm WaterSense median and 2.75 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): PF232301: 1.20; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)PF232301: 1.20PF2323011.20EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.2 gpm: 1.2 gpm (67th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.2 gpm: 1.2 gpm (P67)

Which framing and flange tolerances matter before installing PHOENIX PF232301?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does PHOENIX PF232301 compare to WaterSense category caps?

Each specification row below documents PHOENIX PF232301 tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share PHOENIX (14 certified) EPA WaterSense Partner
Model Number / Series PF232301 Certified Series (1 finish variants)
Rated Consumption 1.2 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How many gallons per year does PHOENIX PF232301 cut?

Calculated annual water budgets below quantify PHOENIX PF232301 savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for PHOENIX PF232301 (1.2 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,752 gal1,460 gal2,263 gal (~$25)
2 Occupants3,504 gal2,920 gal4,526 gal (~$50)
3 Occupants5,256 gal4,380 gal6,789 gal (~$54–$122)
4 Occupants7,008 gal5,840 gal9,052 gal (~$100)

Which competing models share PHOENIX PF232301 flow tier?

Review five peer WaterSense units matching PHOENIX PF232301 conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
1858 LUM211-PU 1.2 gpm (Same flow) Lumoni
Aidier ID-B3594 1.2 gpm (Same flow) WaterSense
Axor 48170xx1 1.2 gpm (Same flow) Axoror One
B&K 221-015 1.2 gpm (Same flow) Lavatory Faucet
B&K 222-311H 1.2 gpm (Same flow) Lavatory Faucet

Can you estimate PHOENIX PF232301 payback in your home?

Test how many gallons and dollars PHOENIX PF232301 saves each year by entering your household residents and local water-sewer rate below.

What plumbing or duct constraints rule out PHOENIX PF232301?

Compare where PHOENIX PF232301 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Homeowner profile: Upgrading 2.75 gpm fixtures for 56.4% water reduction
  • Suited to: Matching PHOENIX SKU PF232301 certification on rebate forms

How do federal and code standards apply to PHOENIX PF232301?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for PHOENIX PF232301.

When can PHOENIX PF232301 (1.2 gpm) underperform in an older bathroom?

Skip PHOENIX PF232301 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

How do 133 WaterSense rebate programs treat PHOENIX PF232301?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like PHOENIX PF232301, itemized purchase invoices, and residential installation addresses.

How does PHOENIX PF232301 perform relative to the EPA WaterSense category median?

Among certified WaterSense faucets, the national median stands at 1.2 gpm. At 1.2 gpm, PHOENIX PF232301 sits equal to the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to PHOENIX PF232301?

At $11 per 1,000 gallons, a 3-person household conserving 24,528 gallons/yr with PHOENIX PF232301 trims roughly $270 annually off water and sewer utility bills.

What anti-scald valve standard pairs with PHOENIX PF232301?

Pairing PHOENIX PF232301 (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing PHOENIX PF232301 require a municipal plumbing permit?

Like-for-like swaps using PHOENIX PF232301 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 4.0 gpm fixture to PHOENIX PF232301 at 1.2 gpm?

Swapping a 4.0 gpm unit for PHOENIX PF232301 slashes water draw 70.0% (8,176 gal/person/yr), beating 2.2 gpm federal EPAct standards by 45.5%.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories