Verified by EPA WaterSense at 1.2 gpm, Premier™ 120332LF sits 45.5% under federal 2.2 gpm ceilings (#1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets) and saves ~6,789 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for Premier™ 120332LF WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.2 gpm
- vs. EPAct 1992
- -45.5% (2.2 gpm)
- Annual Draw (1 Pers.)
- 1,752 gal/yr
- Annual Saved vs. Legacy
- 2,263 gal/person
- Brand EPA Count
- 87 faucets
- Series / Variants
- 120332LF (10)

What does Premier™ 120332LF Benchmark & Water Budget show?
Under EPA WaterSense protocols, Premier™ 120332LF (Essen) delivers 1.2 gpm (#1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets), beating the 2.2 gpm federal ceiling by 45.5%.
Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.
Brand breadth: Premier™ holds 87 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Prescott (AZ) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).
Where does Premier™ 120332LF rank among 22,471 certified faucets?
Review how Premier™ 120332LF (1.20 gpm) places inside EPA WaterSense's 22,471-SKU faucet registry alongside historical 2.75 gpm units.
What plumbing rough-in clearances prevent leaks around Premier™ 120332LF?
Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.
Which certified attributes define Premier™ 120332LF performance?
Official U.S. EPA WaterSense registry entries below confirm Premier™ 120332LF rated flow rate, model series status, and household code fit.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | Premier™ (87 certified) | EPA WaterSense Partner |
| Model Number / Series | 120332LF | Essen (10 finish variants) |
| Rated Consumption | 1.2 gpm | Category median 1.2 gpm (n=22,471 rated) |
| Shower / Faucet Pairing | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |
Which 10 finish and trim SKUs share the Premier™ 120332LF WaterSense spec?
Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 8 representative EPA SKU variations are consolidated below.
| Certified Finish SKU | Verified Flow | Series Designation |
|---|---|---|
| 120332LF | 1.2 gpm | Essen |
| 120123 | 1.2 gpm | Essen |
| 120125 | 1.2 gpm | Essen |
| 2495792 | 1.2 gpm | Essen |
| 120331LF | 1.2 gpm | Essen |
| 120122 | 1.2 gpm | Essen |
| 120124 | 1.2 gpm | Essen |
| 2495796 | 1.2 gpm | Essen |
How do Premier™ 120332LF savings scale from 1 to 4 occupants?
Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to Premier™ 120332LF across different household sizes.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 1,752 gal | 1,460 gal | 2,263 gal (~$25) |
| 2 Occupants | 3,504 gal | 2,920 gal | 4,526 gal (~$50) |
| 3 Occupants | 5,256 gal | 4,380 gal | 6,789 gal (~$54–$122) |
| 4 Occupants | 7,008 gal | 5,840 gal | 9,052 gal (~$100) |
Which peer fixtures deliver flow close to Premier™ 120332LF?
Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.
| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| 1858 LUM211-PU | 1.2 gpm (Same flow) | Lumoni |
| Aidier ID-B3594 | 1.2 gpm (Same flow) | WaterSense |
| Axor 48170xx1 | 1.2 gpm (Same flow) | Axoror One |
| B&K 221-015 | 1.2 gpm (Same flow) | Lavatory Faucet |
| B&K 222-311H | 1.2 gpm (Same flow) | Lavatory Faucet |
Does Premier™ 120332LF pay off faster in high-rate cities?
Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark Premier™ 120332LF annual savings immediately.
What plumbing or duct constraints rule out Premier™ 120332LF?
Compare where Premier™ 120332LF excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Multi-outlet body spray manifold exceeding single-head flow
Best-Fit Homeowner Profiles
- Homeowner profile: Upgrading 2.75 gpm fixtures for 56.4% water reduction
- Suited to: Matching Premier™ SKU 120332LF certification on rebate forms
Where do official rules set limits for Premier™ 120332LF?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Premier™ 120332LF.
Why upgrade a 4.0 gpm fixture to Premier™ 120332LF at 1.2 gpm?
Swapping a 4.0 gpm unit for Premier™ 120332LF slashes water draw 70.0% (8,176 gal/person/yr), beating 2.2 gpm federal EPAct standards by 45.5%.
When can Premier™ 120332LF (1.2 gpm) underperform in an older bathroom?
Skip Premier™ 120332LF without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.
How do 133 WaterSense rebate programs treat Premier™ 120332LF?
Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Premier™ 120332LF, itemized purchase invoices, and residential installation addresses.
How does Premier™ 120332LF perform relative to the EPA WaterSense category median?
Among certified WaterSense faucets, the national median stands at 1.2 gpm. At 1.2 gpm, Premier™ 120332LF sits equal to the category median while clearing federal WaterSense caps.
How much does a 3-resident family save yearly switching to Premier™ 120332LF?
At $11 per 1,000 gallons, a 3-person household conserving 24,528 gallons/yr with Premier™ 120332LF trims roughly $270 annually off water and sewer utility bills.
What anti-scald valve standard pairs with Premier™ 120332LF?
Pairing Premier™ 120332LF (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.
How is EPA WaterSense performance tested beyond raw gpm flow caps?
EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.
Does installing Premier™ 120332LF require a municipal plumbing permit?
Like-for-like swaps using Premier™ 120332LF on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)