Skip to main content
Grant Estimator

QUIK 23BC2 WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · QUIK (1 SKU)
Verified Specification Summary

Verified by EPA WaterSense at 1.5 gpm, QUIK 23BC2 sits 31.8% under federal 2.2 gpm ceilings (#15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm) and saves ~5,475 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for QUIK 23BC2 WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.5 gpm
vs. EPAct 1992
-31.8% (2.2 gpm)
Annual Draw (1 Pers.)
2,190 gal/yr
Annual Saved vs. Legacy
1,825 gal/person
Brand EPA Count
3 faucets
Series / Variants
23BC2 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does QUIK 23BC2 Benchmark & Water Budget show?

Under EPA WaterSense protocols, QUIK 23BC2 delivers 1.5 gpm (#15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm (0.30 gpm higher-flow than the 1.20 gpm median)), beating the 2.2 gpm federal ceiling by 31.8%.

Pair this 1.5 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: QUIK holds 3 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~5,475 gallons/yr—roughly $44/yr in low-tariff towns ($8/1k gal), $60/yr at national averages ($11/1k gal), or $99/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Tucson - Tucson Water (AZ) list active rebates among 200 U.S. programs. Closest alternatives: AM Conservation Group, Inc. FA012CPB1WS (1.5 gpm) and Amazon 90457.05 (1.5 gpm).

Where does QUIK 23BC2 rank among 22,471 certified faucets?

Review how QUIK 23BC2 (1.50 gpm) places inside EPA WaterSense's 22,471-SKU faucet registry alongside historical 2.75 gpm units.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 23BC2: 1.50; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)23BC2: 1.5023BC21.50EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.5 gpm: 1.5 gpm (100th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.5 gpm: 1.5 gpm (P100)

What plumbing rough-in clearances prevent leaks around QUIK 23BC2?

Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which certified attributes define QUIK 23BC2 performance?

Official U.S. EPA WaterSense registry entries below confirm QUIK 23BC2 rated flow rate, model series status, and household code fit.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share QUIK (3 certified) EPA WaterSense Partner
Model Number / Series 23BC2 Certified Series (1 finish variants)
Rated Consumption 1.5 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How do QUIK 23BC2 savings scale from 1 to 4 occupants?

Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to QUIK 23BC2 across different household sizes.

Computed annual water savings for QUIK 23BC2 (1.5 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,190 gal1,022 gal1,825 gal (~$20)
2 Occupants4,380 gal2,044 gal3,650 gal (~$40)
3 Occupants6,570 gal3,066 gal5,475 gal (~$44–$99)
4 Occupants8,760 gal4,088 gal7,300 gal (~$80)

Which peer fixtures deliver flow close to QUIK 23BC2?

Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
AM Conservation Group, Inc. FA012CPB1WS 1.5 gpm (Same flow) WaterSense
Amazon 90457.05 1.5 gpm (Same flow) WaterSense
Aqueous™, Estora™ or Homewerks Worldwide 20-B41CY-Z 1.5 gpm (Same flow) WaterSense
Aqueous™, Estora™ or Homewerks Worldwide 30-B41WN-Z 1.5 gpm (Same flow) WaterSense
Brookfield 192-8268 1.5 gpm (Same flow) CMI 3252C Chrome Two Handle Deluxe...

Does QUIK 23BC2 pay off faster in high-rate cities?

Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark QUIK 23BC2 annual savings immediately.

Where should contractors skip QUIK 23BC2 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for QUIK 23BC2 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Choose this if: Upgrading 2.75 gpm fixtures for 45.5% water reduction
  • Works well for: Matching QUIK SKU 23BC2 certification on rebate forms

Where do official rules set limits for QUIK 23BC2?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing QUIK 23BC2.

Who should NOT install QUIK 23BC2 without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.5 gpm faucet.

Can homeowners claim utility rebates when installing QUIK 23BC2?

Because QUIK 23BC2 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is QUIK 23BC2 leaner than typical WaterSense faucet models?

Compared with the 1.2 gpm WaterSense faucet median, QUIK 23BC2's 1.5 gpm rating places it slightly above category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with QUIK 23BC2?

Upgrading a 4.0 gpm legacy fixture to QUIK 23BC2 saves ~21,900 gallons yearly for three occupants, about $241/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with QUIK 23BC2?

Pairing QUIK 23BC2 (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing QUIK 23BC2 require a municipal plumbing permit?

Like-for-like swaps using QUIK 23BC2 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How many gallons per person does QUIK 23BC2 save annually?

Each resident saves ~7,300 gallons yearly (62.5% drop) replacing a 4.0 gpm fixture with QUIK 23BC2 (1.5 gpm), or 2,044 gal/yr versus 2.2 gpm EPAct baselines.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories