Skip to main content
Grant Estimator

STRUCTURED FLOW LA4200-LP-XX-LF WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · STRUCTURED FLOW (1 SKU)
Verified Specification Summary

Verified by EPA WaterSense at 1.5 gpm, STRUCTURED FLOW LA4200-LP-XX-LF sits 31.8% under federal 2.2 gpm ceilings (#15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm) and saves ~5,475 gal/yr in a 3-person residence. Compare EPA WaterSense certified flow metrics for STRUCTURED FLOW LA4200-LP-XX-LF WaterSense Faucet, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.5 gpm
vs. EPAct 1992
-31.8% (2.2 gpm)
Annual Draw (1 Pers.)
2,190 gal/yr
Annual Saved vs. Legacy
1,825 gal/person
Brand EPA Count
36 faucets
Series / Variants
LA4200-LP-XX-LF (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does STRUCTURED FLOW LA4200-LP-XX-LF Benchmark & Water Budget show?

Under EPA WaterSense protocols, STRUCTURED FLOW LA4200-LP-XX-LF delivers 1.5 gpm (#15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm (0.30 gpm higher-flow than the 1.20 gpm median)), beating the 2.2 gpm federal ceiling by 31.8%.

Pair this 1.5 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: STRUCTURED FLOW holds 36 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~5,475 gallons/yr—roughly $44/yr in low-tariff towns ($8/1k gal), $60/yr at national averages ($11/1k gal), or $99/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Glendale Environmental Resources Department (AZ) list active rebates among 200 U.S. programs. Closest alternatives: AM Conservation Group, Inc. FA012CPB1WS (1.5 gpm) and Amazon 90457.05 (1.5 gpm).

Where does STRUCTURED FLOW LA4200-LP-XX-LF rank among 22,471 certified faucets?

Review how STRUCTURED FLOW LA4200-LP-XX-LF (1.50 gpm) places inside EPA WaterSense's 22,471-SKU faucet registry alongside historical 2.75 gpm units.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): LA4200-LP-XX-LF: 1.50; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)LA4200-LP-XX-LF: 1.50LA4200-LP-XX-LF1.50EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.5 gpm: 1.5 gpm (100th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.5 gpm: 1.5 gpm (P100)

What plumbing rough-in clearances prevent leaks around STRUCTURED FLOW LA4200-LP-XX-LF?

Sound wet-area preparation pairs rigid L/360 subfloor support with flush flange bolts and code-compliant fixture spacing.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

Which certified attributes define STRUCTURED FLOW LA4200-LP-XX-LF performance?

Official U.S. EPA WaterSense registry entries below confirm STRUCTURED FLOW LA4200-LP-XX-LF rated flow rate, model series status, and household code fit.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share STRUCTURED FLOW (36 certified) EPA WaterSense Partner
Model Number / Series LA4200-LP-XX-LF Certified Series (1 finish variants)
Rated Consumption 1.5 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How do STRUCTURED FLOW LA4200-LP-XX-LF savings scale from 1 to 4 occupants?

Inspect side-by-side annual gallon reductions and estimated utility savings when upgrading legacy fixtures to STRUCTURED FLOW LA4200-LP-XX-LF across different household sizes.

Computed annual water savings for STRUCTURED FLOW LA4200-LP-XX-LF (1.5 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,190 gal1,022 gal1,825 gal (~$20)
2 Occupants4,380 gal2,044 gal3,650 gal (~$40)
3 Occupants6,570 gal3,066 gal5,475 gal (~$44–$99)
4 Occupants8,760 gal4,088 gal7,300 gal (~$80)

Which peer fixtures deliver flow close to STRUCTURED FLOW LA4200-LP-XX-LF?

Compare five certified WaterSense alternatives below showing exact flow differences and model details verified in official EPA filings.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
AM Conservation Group, Inc. FA012CPB1WS 1.5 gpm (Same flow) WaterSense
Amazon 90457.05 1.5 gpm (Same flow) WaterSense
Aqueous™, Estora™ or Homewerks Worldwide 20-B41CY-Z 1.5 gpm (Same flow) WaterSense
Aqueous™, Estora™ or Homewerks Worldwide 30-B41WN-Z 1.5 gpm (Same flow) WaterSense
Brookfield 192-8268 1.5 gpm (Same flow) CMI 3252C Chrome Two Handle Deluxe...

Does STRUCTURED FLOW LA4200-LP-XX-LF pay off faster in high-rate cities?

Enter occupants and your combined water plus sewer charge per 1,000 gallons to benchmark STRUCTURED FLOW LA4200-LP-XX-LF annual savings immediately.

Does STRUCTURED FLOW LA4200-LP-XX-LF suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying STRUCTURED FLOW LA4200-LP-XX-LF for your remodel.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Strong scenario: Upgrading 2.75 gpm fixtures for 45.5% water reduction
  • Best application: Matching STRUCTURED FLOW SKU LA4200-LP-XX-LF certification on rebate forms

Where do official rules set limits for STRUCTURED FLOW LA4200-LP-XX-LF?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing STRUCTURED FLOW LA4200-LP-XX-LF.

Where does STRUCTURED FLOW LA4200-LP-XX-LF rank against other certified faucets?

Rated at 1.5 gpm, STRUCTURED FLOW LA4200-LP-XX-LF measures slightly above the 1.2 gpm WaterSense faucet median across thousands of EPA-listed residential fixtures.

Does STRUCTURED FLOW LA4200-LP-XX-LF cut utility costs noticeably for a 3-person household?

Yes: cutting 21,900 gallons/yr relative to 4.0 gpm hardware translates to ~$241/yr in combined water/sewer savings at $11/1k gal.

What anti-scald valve standard pairs with STRUCTURED FLOW LA4200-LP-XX-LF?

Pairing STRUCTURED FLOW LA4200-LP-XX-LF (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing STRUCTURED FLOW LA4200-LP-XX-LF require a municipal plumbing permit?

Like-for-like swaps using STRUCTURED FLOW LA4200-LP-XX-LF on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What efficiency edge separates STRUCTURED FLOW LA4200-LP-XX-LF from legacy and EPAct models?

Certified at 1.5 gpm, STRUCTURED FLOW LA4200-LP-XX-LF achieves 31.8% savings against EPAct 1992 (2.2 gpm) and 62.5% savings against 4.0 gpm fixtures, 7,300 gallons per occupant yearly.

What supply pressure checks protect STRUCTURED FLOW LA4200-LP-XX-LF spray performance?

Ensure at least 30 PSI static water pressure and an ASSE 1016 scald-guard valve; homes with restricted galvanized pipes should test line flow before adding 1.5 gpm trim.

Does STRUCTURED FLOW LA4200-LP-XX-LF qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes STRUCTURED FLOW LA4200-LP-XX-LF eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories