STRUCTURED FLOW LL4110B-XX-LF WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · STRUCTURED FLOW (1 SKU)
Verified Specification Summary

Operating at 1.5 gpm, the STRUCTURED FLOW LL4110B-XX-LF faucet beats 1992 EPAct rules (2.2 gpm) by 31.8% (#15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm), saving a 3-resident home ~5,475 gallons annually compared to 2.75 gpm legacy hardware. Compare EPA WaterSense certified flow metrics for STRUCTURED FLOW LL4110B-XX-LF WaterSense Faucet, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.5 gpm
vs. EPAct 1992
-31.8% (2.2 gpm)
Annual Draw (1 Pers.)
2,190 gal/yr
Annual Saved vs. Legacy
1,825 gal/person
Brand EPA Count
36 faucets
Series / Variants
LL4110B-XX-LF (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does STRUCTURED FLOW LL4110B-XX-LF Benchmark & Water Budget show?

WaterSense benchmark: STRUCTURED FLOW series LL4110B-XX-LF verifies 1.5 gpm delivery, scoring 31.8% leaner than EPAct 1992 (2.2 gpm) at #15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm (0.30 gpm higher-flow than the 1.20 gpm median).

Pair this 1.5 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: STRUCTURED FLOW holds 36 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~5,475 gallons/yr—roughly $44/yr in low-tariff towns ($8/1k gal), $60/yr at national averages ($11/1k gal), or $99/yr in high-rate cities ($18/1k gal). Regional utilities such as California Water Service Company (CA) list active rebates among 200 U.S. programs. Closest alternatives: AM Conservation Group, Inc. FA012CPB1WS (1.5 gpm) and Amazon 90457.05 (1.5 gpm).

How much leaner is STRUCTURED FLOW LL4110B-XX-LF than pre-1994 2.75 gpm plumbing?

Flow distribution bars contrast STRUCTURED FLOW LL4110B-XX-LF (1.50 gpm) directly with the 1.2 gpm WaterSense median and 2.75 gpm older fixtures.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): LL4110B-XX-LF: 1.50; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)LL4110B-XX-LF: 1.50LL4110B-XX-LF1.50EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.5 gpm: 1.5 gpm (100th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.5 gpm: 1.5 gpm (P100)

Which framing and flange tolerances matter before installing STRUCTURED FLOW LL4110B-XX-LF?

Proper subfloor priming, perimeter expansion strips, and level flange rings prevent rocking bowls and subfloor moisture intrusion under bath trim.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

How does STRUCTURED FLOW LL4110B-XX-LF compare to WaterSense category caps?

Each specification row below documents STRUCTURED FLOW LL4110B-XX-LF tested consumption against national EPA category medians and EPAct 1992 federal baselines.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share STRUCTURED FLOW (36 certified) EPA WaterSense Partner
Model Number / Series LL4110B-XX-LF Certified Series (1 finish variants)
Rated Consumption 1.5 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

How many gallons per year does STRUCTURED FLOW LL4110B-XX-LF cut?

Calculated annual water budgets below quantify STRUCTURED FLOW LL4110B-XX-LF savings per occupant and estimated combined water-sewer bill reductions across household sizes.

Computed annual water savings for STRUCTURED FLOW LL4110B-XX-LF (1.5 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,190 gal1,022 gal1,825 gal (~$20)
2 Occupants4,380 gal2,044 gal3,650 gal (~$40)
3 Occupants6,570 gal3,066 gal5,475 gal (~$44–$99)
4 Occupants8,760 gal4,088 gal7,300 gal (~$80)

Which competing models share STRUCTURED FLOW LL4110B-XX-LF flow tier?

Review five peer WaterSense units matching STRUCTURED FLOW LL4110B-XX-LF conservation range so homeowners can verify contractor fixture swaps on written bids.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
AM Conservation Group, Inc. FA012CPB1WS 1.5 gpm (Same flow) WaterSense
Amazon 90457.05 1.5 gpm (Same flow) WaterSense
Aqueous™, Estora™ or Homewerks Worldwide 20-B41CY-Z 1.5 gpm (Same flow) WaterSense
Aqueous™, Estora™ or Homewerks Worldwide 30-B41WN-Z 1.5 gpm (Same flow) WaterSense
Brookfield 192-8268 1.5 gpm (Same flow) CMI 3252C Chrome Two Handle Deluxe...

Can you estimate STRUCTURED FLOW LL4110B-XX-LF payback in your home?

Test how many gallons and dollars STRUCTURED FLOW LL4110B-XX-LF saves each year by entering your household residents and local water-sewer rate below.

Who should not install STRUCTURED FLOW LL4110B-XX-LF in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting STRUCTURED FLOW LL4110B-XX-LF for residential use.

Limitations & Who Should Skip

  • Multi-outlet body spray manifold exceeding single-head flow

Best-Fit Homeowner Profiles

  • Ideal fit: Upgrading 2.75 gpm fixtures for 45.5% water reduction
  • Primary match: Matching STRUCTURED FLOW SKU LL4110B-XX-LF certification on rebate forms

How do federal and code standards apply to STRUCTURED FLOW LL4110B-XX-LF?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for STRUCTURED FLOW LL4110B-XX-LF.

Can homeowners claim utility rebates when installing STRUCTURED FLOW LL4110B-XX-LF?

Because STRUCTURED FLOW LL4110B-XX-LF holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.

Is STRUCTURED FLOW LL4110B-XX-LF leaner than typical WaterSense faucet models?

Compared with the 1.2 gpm WaterSense faucet median, STRUCTURED FLOW LL4110B-XX-LF's 1.5 gpm rating places it slightly above category norms inside EPA conservation limits.

What annual dollar savings can a 3-person home expect with STRUCTURED FLOW LL4110B-XX-LF?

Upgrading a 4.0 gpm legacy fixture to STRUCTURED FLOW LL4110B-XX-LF saves ~21,900 gallons yearly for three occupants, about $241/yr at $11 per 1,000 gallons combined water and sewer.

What anti-scald valve standard pairs with STRUCTURED FLOW LL4110B-XX-LF?

Pairing STRUCTURED FLOW LL4110B-XX-LF (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing STRUCTURED FLOW LL4110B-XX-LF require a municipal plumbing permit?

Like-for-like swaps using STRUCTURED FLOW LL4110B-XX-LF on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

How much water does STRUCTURED FLOW LL4110B-XX-LF save compared with EPAct 1992 and pre-1994 fixtures?

Rated at 1.5 gpm, STRUCTURED FLOW LL4110B-XX-LF cuts 31.8% below the 2.2 gpm EPAct 1992 ceiling and 62.5% under 4.0 gpm legacy units, saving 7,300 gal/person/yr (2,044 vs EPAct).

Who should NOT install STRUCTURED FLOW LL4110B-XX-LF without checking house plumbing first?

Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.5 gpm faucet.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories