Certified under EPA WaterSense, Taymor 06-4629P tests at 1.5 gpm (#15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm), trimming 31.8% off the 2.2 gpm federal cap while cutting 3-person household draw by ~5,475 gal/yr versus 2.75 gpm fixtures. Compare EPA WaterSense certified flow metrics for Taymor 06-4629P WaterSense Faucet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.5 gpm
- vs. EPAct 1992
- -31.8% (2.2 gpm)
- Annual Draw (1 Pers.)
- 2,190 gal/yr
- Annual Saved vs. Legacy
- 1,825 gal/person
- Brand EPA Count
- 96 faucets
- Series / Variants
- 06-4629P (4)

What does Taymor 06-4629P Benchmark & Water Budget show?
Efficiency check: certified at 1.5 gpm, Taymor 06-4629P (LUNA) trims 31.8% under federal 2.2 gpm caps; #15,105 of 22,471 certified faucets; tied with 7,366 other certified faucets at 1.50 gpm (0.30 gpm higher-flow than the 1.20 gpm median).
Pair this 1.5 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.
Brand breadth: Taymor holds 96 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~5,475 gallons/yr—roughly $44/yr in low-tariff towns ($8/1k gal), $60/yr at national averages ($11/1k gal), or $99/yr in high-rate cities ($18/1k gal). Regional utilities such as Liberty Utilities - Arizona (AZ) list active rebates among 200 U.S. programs. Closest alternatives: AM Conservation Group, Inc. FA012CPB1WS (1.5 gpm) and Amazon 90457.05 (1.5 gpm).
Where does Taymor 06-4629P sit on the EPA WaterSense faucet flow curve?
Comparing Taymor 06-4629P (1.50 gpm) against federal EPAct (2.2 gpm) and legacy (2.75 gpm) baselines shows immediate per-use conservation.
How do subfloor levelness and rough-in height protect Taymor 06-4629P?
Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.
What official WaterSense figures verify Taymor 06-4629P?
Examine Taymor 06-4629P certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | Taymor (96 certified) | EPA WaterSense Partner |
| Model Number / Series | 06-4629P | LUNA (4 finish variants) |
| Rated Consumption | 1.5 gpm | Category median 1.2 gpm (n=22,471 rated) |
| Shower / Faucet Pairing | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |
Which 4 finish and trim SKUs share the Taymor 06-4629P WaterSense spec?
Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 4 representative EPA SKU variations are consolidated below.
| Certified Finish SKU | Verified Flow | Series Designation |
|---|---|---|
| 06-4629P | 1.5 gpm | LUNA |
| 06-4122V | 1.5 gpm | LUNA |
| 06-4627V | 1.5 gpm | LUNA |
| 06-4629PBLK | 1.5 gpm | LUNA |
What annual utility savings does Taymor 06-4629P deliver?
Compare 1-to-4-person household water use with Taymor 06-4629P against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 2,190 gal | 1,022 gal | 1,825 gal (~$20) |
| 2 Occupants | 4,380 gal | 2,044 gal | 3,650 gal (~$40) |
| 3 Occupants | 6,570 gal | 3,066 gal | 5,475 gal (~$44–$99) |
| 4 Occupants | 8,760 gal | 4,088 gal | 7,300 gal (~$80) |
What alternative WaterSense models compare to Taymor 06-4629P?
Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.
| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| AM Conservation Group, Inc. FA012CPB1WS | 1.5 gpm (Same flow) | WaterSense |
| Amazon 90457.05 | 1.5 gpm (Same flow) | WaterSense |
| Aqueous™, Estora™ or Homewerks Worldwide 20-B41CY-Z | 1.5 gpm (Same flow) | WaterSense |
| Aqueous™, Estora™ or Homewerks Worldwide 30-B41WN-Z | 1.5 gpm (Same flow) | WaterSense |
| Brookfield 192-8268 | 1.5 gpm (Same flow) | CMI 3252C Chrome Two Handle Deluxe... |
What will Taymor 06-4629P save on your annual water bill?
Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.
Where should contractors skip Taymor 06-4629P on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Taymor 06-4629P carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Existing shower valve lacks ASSE 1016 pressure balancing
Best-Fit Homeowner Profiles
- Choose this if: Meeting 2.2 gpm federal & stricter WaterSense caps
- Works well for: Targeting ~$60/yr utility savings (3-person home)
Which homeowner questions come up most for Taymor 06-4629P?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Taymor 06-4629P.
Is Taymor 06-4629P leaner than typical WaterSense faucet models?
Compared with the 1.2 gpm WaterSense faucet median, Taymor 06-4629P's 1.5 gpm rating places it slightly above category norms inside EPA conservation limits.
What annual dollar savings can a 3-person home expect with Taymor 06-4629P?
Upgrading a 4.0 gpm legacy fixture to Taymor 06-4629P saves ~21,900 gallons yearly for three occupants, about $241/yr at $11 per 1,000 gallons combined water and sewer.
What anti-scald valve standard pairs with Taymor 06-4629P?
Pairing Taymor 06-4629P (1.5 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.
How is EPA WaterSense performance tested beyond raw gpm flow caps?
EPA WaterSense certification pairs the 1.5 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.
Does installing Taymor 06-4629P require a municipal plumbing permit?
Like-for-like swaps using Taymor 06-4629P on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
How many gallons per person does Taymor 06-4629P save annually?
Each resident saves ~7,300 gallons yearly (62.5% drop) replacing a 4.0 gpm fixture with Taymor 06-4629P (1.5 gpm), or 2,044 gal/yr versus 2.2 gpm EPAct baselines.
Who should NOT install Taymor 06-4629P without checking house plumbing first?
Bathrooms with low supply pressure under 30 PSI, un-balanced two-handle valves lacking ASSE 1016 protection, or multi-spray manifolds should verify pressure dynamics before fitting a 1.5 gpm faucet.
Can homeowners claim utility rebates when installing Taymor 06-4629P?
Because Taymor 06-4629P holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)