Homeowners upgrading older 2.75 gpm plumbing to Victoria + Albert TU-19 (1.2 gpm, #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets) cut 56.4% off legacy draw, conserving ~6,789 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for Victoria + Albert TU-19 WaterSense Faucet, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.2 gpm
- vs. EPAct 1992
- -45.5% (2.2 gpm)
- Annual Draw (1 Pers.)
- 1,752 gal/yr
- Annual Saved vs. Legacy
- 2,263 gal/person
- Brand EPA Count
- 6 faucets
- Series / Variants
- TU-19 (1)

What does Victoria + Albert TU-19 Benchmark & Water Budget show?
Laboratory testing places Victoria + Albert TU-19 (Tubo 19) at 1.2 gpm (aggressive sub-1.6 gpm conservation tier), saving 45.5% vs. EPAct 1992 (2.2 gpm) while ranking #1,711 of 22,471 certified faucets; at the median tier among 22,471 certified faucets; lower-flow than 32.9% of certified faucets.
Pair this 1.2 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.
Brand breadth: Victoria + Albert holds 6 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~6,789 gallons/yr—roughly $54/yr in low-tariff towns ($8/1k gal), $75/yr at national averages ($11/1k gal), or $122/yr in high-rate cities ($18/1k gal). Regional utilities such as Big Bear Lake Department of Water and Power (CA) list active rebates among 200 U.S. programs. Closest alternatives: 1858 LUM211-PU (1.2 gpm) and Aidier ID-B3594 (1.2 gpm).
How do federal gpm limits contrast with Victoria + Albert TU-19 tested flow?
Each bar isolates Victoria + Albert TU-19 (1.20 gpm) relative to the EPA cap, federal EPAct 1992 standard (2.2 gpm), and pre-1994 draw.
How does wet-zone tile prep interact with Victoria + Albert TU-19 rough-ins?
Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.
What plumbing standards accompany Victoria + Albert TU-19 installation?
Verify Victoria + Albert TU-19 EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | Victoria + Albert (6 certified) | EPA WaterSense Partner |
| Model Number / Series | TU-19 | Tubo 19 (1 finish variants) |
| Rated Consumption | 1.2 gpm | Category median 1.2 gpm (n=22,471 rated) |
| Shower / Faucet Pairing | Pair w/ ASSE 1016 valve (IPC 412.3) | Verify rough-in & supply pressure |
What household water budget fits Victoria + Albert TU-19?
Annual consumption rows below translate Victoria + Albert TU-19 certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 1,752 gal | 1,460 gal | 2,263 gal (~$25) |
| 2 Occupants | 3,504 gal | 2,920 gal | 4,526 gal (~$50) |
| 3 Occupants | 5,256 gal | 4,380 gal | 6,789 gal (~$54–$122) |
| 4 Occupants | 7,008 gal | 5,840 gal | 9,052 gal (~$100) |
Where can buyers find alternatives to Victoria + Albert TU-19?
Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.
| Peer Brand & Model | Rated GPM (Delta) | Flush / Model Detail |
|---|---|---|
| 1858 LUM211-PU | 1.2 gpm (Same flow) | Lumoni |
| Aidier ID-B3594 | 1.2 gpm (Same flow) | WaterSense |
| Axor 48170xx1 | 1.2 gpm (Same flow) | Axoror One |
| B&K 221-015 | 1.2 gpm (Same flow) | Lavatory Faucet |
| B&K 222-311H | 1.2 gpm (Same flow) | Lavatory Faucet |
What annual bill drop does Victoria + Albert TU-19 achieve for your family?
Calculate annual gallons conserved and dollar savings for Victoria + Albert TU-19 using your exact occupant count and utility tariff without submitting personal info.
What plumbing or duct constraints rule out Victoria + Albert TU-19?
Compare where Victoria + Albert TU-19 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Existing shower valve lacks ASSE 1016 pressure balancing
Best-Fit Homeowner Profiles
- Homeowner profile: Meeting 2.2 gpm federal & stricter WaterSense caps
- Suited to: Targeting ~$75/yr utility savings (3-person home)
Which code checks and cost facts matter for Victoria + Albert TU-19?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Victoria + Albert TU-19.
How do 133 WaterSense rebate programs treat Victoria + Albert TU-19?
Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Victoria + Albert TU-19, itemized purchase invoices, and residential installation addresses.
How does Victoria + Albert TU-19 perform relative to the EPA WaterSense category median?
Among certified WaterSense faucets, the national median stands at 1.2 gpm. At 1.2 gpm, Victoria + Albert TU-19 sits equal to the category median while clearing federal WaterSense caps.
How much does a 3-resident family save yearly switching to Victoria + Albert TU-19?
At $11 per 1,000 gallons, a 3-person household conserving 24,528 gallons/yr with Victoria + Albert TU-19 trims roughly $270 annually off water and sewer utility bills.
What anti-scald valve standard pairs with Victoria + Albert TU-19?
Pairing Victoria + Albert TU-19 (1.2 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.
How is EPA WaterSense performance tested beyond raw gpm flow caps?
EPA WaterSense certification pairs the 1.2 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.
Does installing Victoria + Albert TU-19 require a municipal plumbing permit?
Like-for-like swaps using Victoria + Albert TU-19 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
Why upgrade a 4.0 gpm fixture to Victoria + Albert TU-19 at 1.2 gpm?
Swapping a 4.0 gpm unit for Victoria + Albert TU-19 slashes water draw 70.0% (8,176 gal/person/yr), beating 2.2 gpm federal EPAct standards by 45.5%.
When can Victoria + Albert TU-19 (1.2 gpm) underperform in an older bathroom?
Skip Victoria + Albert TU-19 without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)